REMOTE CONTROL FOR DAYLIGHT HARVEST SENSOR
HRC-11
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES. ! Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or use of this product, consult a competent electrician
Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com or
robusdirect.com
Permanent ON/OFF function
ON/
OFF
Press button "ON/OFF" to select permanent ON or permanent OFF mode.
Press button "AUTO", "RESET" to quit this mode.
Reset Settings
Press button "RESET", all settings go back to rotary switch settings.
Shift Button
Press button "Shift", the LED on the top left corner is on to indicate mode selection.
All values / settings in RED are valid for 20 seconds.
AUTO mode
Press button "AUTO" to initiate automatic mode. The sensor starts working and all
settings remain as before the light is switched ON/OFF.
Note: "Semi-auto" function is disabled.
Power output
Press the buttons to select light output at 80% (at initial 10,000 hours) or 100%.
Note: "Sensor off" and "Twilight" functions are disabled.
Brightness +/-
Press the buttons to adjust the light brightness during hold-time.
Scene program - 1-key commissioning
1. Press button "Start" to program.
2. Select the buttons in "Detection range", "Daylight threshold", "Hold-time", "Stand-by time", "Stand-by dimming
level" to set all parameters.
3. Press button "Memory" to save all the settings programmed in the remote control.
4. Press button "Apply" to set the settings to each sensor unit(s).
For example, to set detection range 100%, daylight threshold Disable, hold-time 5min, stand-by time +∞, stand-by dimming
level 30%, the steps should be: Press button "Start", button "100%", "Disable", "Shift", "5min", "Shift", "+∞", "30%", "Memory".
By pointing to the sensor unit(s) and pressing "Apply", all settings are passed on the sensor(s).
Detection range
Press buttons in zone "Detection range" to set detection range at 100% / 75% / 50% / 10%.
Daylight threshold
Press buttons in zone " Daylight threshold" to set daylight sensor at 2Lux/ 10Lux / 50Lux / 100Lux / 300Lux
/ 500Lux / Disable. Note: To set daylight sensor at 100Lux / 300Lux/ 500Lux, press "Shift" button first.
Ambient daylight threshold
1. Press button "Shift", the red LED starts to flash.
2. Press button "Ambient", the surrounding lux level is sampled and set as the new daylight threshold.
Hold-time
Press buttons in zone "hold-time" to set the hold-time at 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min.
Note: 1. To set hold-time at 30s / 5min / 15min / 30min, press "Shift" button first.
2. 2s is for testing purpose only, stand-by period and daylight sensor sttings are disabled in this mode.
To exit from test mode, press button "Reset" or any button in "Hold-time".
Stand-by time (corridor function)
Press buttons in zone "stand-by time" to set the stand-by period at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞.
Note: "0s" means on/off control; "+∞" means bi-level control, the fixture is 100% on when there is motion detected,
and remains at the standby dimming level when no presence after motion hold-time.
Stand-by dimming level
Press the button in zone "stand-by dimming level" to set the stand-by dimming level at 10% / 20% / 30% / 50%.
Note: the function of 24h/12h/4h/30s are disabled.
Auto-configuration function
All buttons in this zone are disabled.
Information for the Product user:
1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed out wheelie bin symbol).
2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you
are purchasing a replacement.
3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE
chain
4. The "crossed out wheelie bin symbol" on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations
L.E.D lighting & Electrical Distribution Group UC
IRE: Nangor Road, Dublin 12, D12 E7VP, Ireland
UK: Bracknell Enterprise & Innovation Hub, Ocean
House, 12th Floor, The Ring, Bracknell,
Berkshire RG12 1AX, UK
Issue 1 220819
Tel: +353 1 7099000
Fax: +353 1 7099060
Email: info@robus.com
Website: www.robus.com
Note:
& A
HRC-11
Load Indication:
receiving the commamd from the
remote control successfully.
Dual tech & RF mode
1. Press buttons in this zone to select sensor
technology.
HF+PIR: the light is on when both HF and
PIR sensors are activated.
HF/PIR: the light is on when HF or PIR
sensors are activated.
2. Learn / Erase, Transmit, RX100% and RX
STBY% are disabled.
EN
Page1

Advertisement

loading
Need help?

Need help?

Do you have a question about the HRC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hytronik HRC

  • Page 1 REMOTE CONTROL FOR DAYLIGHT HARVEST SENSOR HRC-11 PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES. ! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician Note: Product technical information and specification may change over time without prior notification.
  • Page 2 AFSTANDSBEDIENING VOOR DAGLICHTREGELINGSSENSOR HRC-11 LEES DE INSTRUCTIES VOORDAT U BEGINT MET DE INSTALLATIE EN HOU ZE BIJ VOOR LATER. ! Elektrische producten kunnen de dood of letsel veroorzaken of eigendommen beschadigen. Als u twijfelt over de installatie of het gebruik van dit product, raadpleeg dan een erkende elektricien Opmerkingen: Technische gegevens en specificaties van dit product kunnen zonder voorafgaande kennisgeving wijzigen.
  • Page 3 FERNBEDIENUNG FÜR TAGESLICHTNUTZUNGSSENSOR HRC-11 LESEN SIE DIE ANLEITUNG, BEVOR SIE MIT DER INSTALLATION BEGINNEN, UND BEWAHREN SIE SIE FÜR DIE SPÄTERE VERWENDUNG AUF. ! Elektronikprodukte können Tod, schwere Verletzungen oder. Sachschaden verursachen. Bei Zweifeln hinsichtlich der Installation oder des Gebrauchs konsultieren Sie einen qualifizierten Elektriker.
  • Page 4 TÉLÉCOMMANDE DE CAPTEUR CRÉPUSCULAIRE HRC-11 VEUILLEZ LIRE LES INSTRUCTIONS AVANT DE COMMENCER L’INSTALLATION ET CONSERVEZ-LES POUR TOUTES UTILISATIONS FUTURES. Les produits électriques peuvent causer la mort, de graves blessures ou des dégâts matériels. Si vous avez des doutes sur l’installation ou sur l’utilisation de ce produit, veuillez consulter un électricien compétent.

This manual is also suitable for:

Hrc-11