Quick Links

USER MANUAL
Sol-H450 / Sol-H500
AC Version
Ver:1.1,2023-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sol-H450 and is the answer not in the manual?

Questions and answers

Summary of Contents for Solenso Sol-H450

  • Page 1 USER MANUAL Sol-H450 / Sol-H500 AC Version Ver:1.1,2023-01...
  • Page 2 About the Manual This manual contains important instructions for the Sol-H450 / Sol-H500 Microinverter and must be read in its entirety before installing or commissioning the equipment. For safety, only qualified technician, who has received training or has demonstrated skills can install and maintain this Microinverter under the guide of this document.
  • Page 3: Table Of Contents

    5.2 Storage and Transportation...................15 5.3 Disposal ...........................16 6.Technical Data..........................17 Appendix 1: ............................18 Installation Map ........................18 Appendix 2: ............................19 WIRING DIAGRAM – 230VAC SINGLE PHASE: ............19 WIRING DIAGRAM – 230VAC / 400VAC THREE PHASE:........... 20 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 4: Important Safety Instructions

    When disconnecting, disconnect the AC by opening the branch circuit breaker first but maintain the protective earthing conductor in the branch circuit breaker connect to the inverter, then disconnect the DC inputs. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 5: Radio Interference Statement

    B) Consult the dealer or an experienced radio / TV technical for help. Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate the equipment. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 6: The Meaning Of Symbols

    CE mark The inverter complies with the requirements of the Low Voltage Directive for the European Union. Read manual first Please read the installation manual first before installation, operation and maintenance. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 7: Microinverter System Introduction

    2.2 Microinverter Highlights Maximum output power up to 500W; Adapted to 60 & 72 cells PV panels. CEC weighted efficiency 96.50%. MPPT efficiency 99.5%. High reliability: NEMA6 (IP67) enclosure ,6000V surge protection. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 8: Terminals Introduction

    2.3 Terminals Introduction Object Description AC Connector DC Connectors 2.4G Wireless Terminal 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 9: Operation Mode

    The current condition is contradicted with Microinverter operating requirement. No house loads or the Export control value has been set as ‘0’ on the SLT under the Zero Export Control mode. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 10: About Installation

    Referring to the Technical Data to make sure the environmental conditions fit the microinverter’s requirement (degree of protection, temperature, humidity, altitude, etc.) To avoid power de-rating due to an increase in the microinverter internal temperature, do 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 11: Installation Steps

    The connectors of the AC Trunk Cable should be spaced based on the spacing between microinverters to ensure that they can properly matched. (S provides AC Trunk Cable with different AC Trunk Connector spacing.) 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 12: Step 3. Connect Ac Cables Of Microinverter

    A) Mount the PV modules above the microinverter. B) Connect the PV modules’ DC cables to the DC input side of the microinverter. Note: Make sure that the AC Trunk Connectors are kept away from any drainage channels. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 13: Step 6. Connect Ac End Cable Cap

    Step 6. Connect AC End Cable Cap A. Strip cable jacket. B.Insert the cable end into the seal. C . Rotate the nut with 3 . 3N . m untilthe latching mechanism meets the base 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 14: Step 7. Connect Ac End Cable To Distribution Box

    Step 9. Set Up the Monitoring System Refer to the SLT User Manual or SLT Quick Installation Guide, and Quick Installation Guide for Solenso Monitoring Platform Online Registration to install the SLT and set up your monitoring system. 202301 V1.1...
  • Page 15: Troubleshooting

    3.Other Status Flashing Red and Green alternately: Firmware is corrupted. *Note: All the faults are reported to the SLT, refer to the local APP of the SLT or Solenso Monitoring Platform for more information. 4.2 On-site Inspection (For qualified installer only) To troubleshoot an inoperable microinverter, follow the steps in the order shown.
  • Page 16: Routine Maintenance

    5kg weight and can be fully closed if the original packaging is no longer available. 5.2 Storage and Transportation Solenso packages and protects individual components using suitable means to make the transport and subsequent handling easier. Transportation of the equipment, especially by road, must be carried out by suitable ways for protecting the components (in particular, the electronic components) from violent, shocks, humidity, vibration, etc.
  • Page 17: Disposal

    Take a complete inspection when restarting after a long time or prolonged stop. Please dispose the equipment properly after scrapping, which are potentially harmful to the environment, in accordance with the regulations in force in the country of installation. 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 18: Technical Data

    Enclosure rating IP67 Cooling Natural convection Features Wireless_2.4G Communication High Frequency Transformers Isolation Type ( Galvanically Isolated) Solenso Monitoring System Monitoring (Solenso DTU is required) EN 50549-1: 2019, VDE-R-N 4105: Compliance 2018 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 19: Installation Map

    Appendix 1: Installation Map 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 20: Wiring Diagram - 230Vac Single Phase

    Appendix 2: WIRING DIAGRAM – 230VAC SINGLE PHASE: 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.
  • Page 21: Wiring Diagram - 230Vac / 400Vac Three Phase

    WIRING DIAGRAM – 230VAC / 400VAC THREE PHASE: 202301 V1.1 Copyright @ Solenso electronic materials Co., LTD.