CAUTION:
1. Conditions for use
This micro abrasive blaster may only be operated:
• Indoors;
• Below 1981 m (6500 ft) above sea level altitude;
• Ambient air temperature between 40°-105°F (5-40°C);
• Maximum relative humidity of 80% at 31°C (88°F);
• Power supply current fluctuations does not exceed 10% of nominal value;
• Under level 2 contamination conditions;
• Supply cool, dry air only, at a maximum pressure of 10.3 Bar (150 PSI).
2. safety
WARNING:
with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/
or serious injury.
Save all warnings and instructions for future reference.
The term "power tool" in the warnings refers to your mains-operated (corded) power tool or
BATTERY-operated (cordless) power tool.
1.
Work area safety:
a.
Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b.
Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust
or fumes.
c.
Keep children and bystanders away while operating this power tool. Distractions can
cause you to lose control.
2.
Electrical Safety:
a.
Power tool plugs must match the outlet. Never modify the plug in any way. Do not use
any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching
outlets will reduce risk of electric shock.
b.
Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is earthed
or grounded.
c.
Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d.
Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or
entangled cords increase the risk of electric shock.
25799 Jefferson Ave.
Murrieta, CA 92562
ORIGINAL INSTRUCTIONS
Read the instructions before using this equipment
Master Problast 3 titan
Read all safety warnings, instructions, illustrations and specifications provided
1-800-VANIMAN (826-4626) USA
english
www.vaniman.com
sales@vaniman.
MPBt - 12/24 Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Master Problast 3 Titan and is the answer not in the manual?

Questions and answers

Summary of Contents for Vaniman Master Problast 3 Titan

  • Page 1 ORIGINAL INSTRUCTIONS CAUTION: Read the instructions before using this equipment Master Problast 3 titan english 1. Conditions for use This micro abrasive blaster may only be operated: • Indoors; • Below 1981 m (6500 ft) above sea level altitude; • Ambient air temperature between 40°-105°F (5-40°C);...
  • Page 2: Personal Safety

    Master Problast 3 titan english When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. If operating a power tool in a damp location is unavoidable, use a RESIDUAL CURRENT DEVICE (RCD) protected supply.
  • Page 3 Master Problast 3 titan english Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
  • Page 4: Liability Exclusion

    4. liability exClusion Vaniman Manufacturing shall be absolved from all claims for damages and warranty if: • The product is used for any purpose other than it was designed for.
  • Page 5: Packing List

    1/4" (6mm) ID (inside diameter) hose while the IO/Master units come equipped with a quick disconnect fitting for a 1/4" (6mm) OD (outside diameter) air line. All Vaniman units are shipped with both fittings included to meet the customer's needs. For more help on connecting your unit to an air supply visit: www.vaniman.com/air-supply-connections-blasters/...
  • Page 6: Maintenance

    PN: 10209 MaintenanCe Vaniman blasters are designed to be low maintenance. However, as the materials used in a microblaster are abrasive by design, components do wear out. A few minor areas should be maintained regularly for a long product life.
  • Page 7 Replace when necessary. Moisture: Vaniman blaster regulators include a filter for small amounts of oil and moisture. If moisture causes the media to clump or cake in the tanks, improper media flow will result. Be sure the air supply is relatively oil and moisture free.
  • Page 8 Master Problast 3 titan english handPieCe Parts Number Description Part Number Corresponding Units Anti-Static Handpiece Tubing 97928 (2ft.) -SandStorm Edge, Professional, 2, Expert, & Problast 2 97929 (3ft.) -SandStorm XL & Problast 97930 (4ft.) -SandStorm Prestige & Problast 3 2192 (by the foot)
  • Page 9 Master Problast 3 titan 2234 Pinch Valve Válvula Vannes à pincement Quetschventil Valvola a Manicotto Válvula ensamblada de Ensemble de soupape de 2283 Vent Valve Ventilbaugruppe Gruppo Valvola di Sfogo ventilación ventilateur Ensamblado de Regulador 2286 Regulator Ensemble régulateur filtre...
  • Page 10 Master Problast 3 titan PluMbing Air Supply In Foot Pedal 25799 Jefferson Ave. Murrieta, CA 92562 1-800-VANIMAN (826-4626) USA www.vaniman.com sales@vaniman.     MPBt - 12/24 Page 10...