For the proper functioning of this product, the 2 parts are mandatory. Please take care to properly install the touchscreen thermostat where the user will have access and the master thermostat near the furnace (gas/electric) for a simple and efficient connection. Touchscreen thermostat 4 Wire Connection Master thermostat Kinghome Canda...
• L-----Refrigerant Leak Signal • ERV--Dry contact to ERV • O/B---4ways valve • DH—-Dry contact to DHUM • Y------Compressor Signal • G-----Fan Signal • HUM---Dry Contact to HUM • W-------Gas Furnace Stage 1 Signal • W2/AUX---Gas Furnace Stage 2/Air Handler Signal Kinghome Canda...
Page 5
Wiring Schematic with Gas Furnace Kinghome Canda...
Page 6
Schematic with Gas Furnace / Defrost option Ex:100°F Limit switch Note: Limit switch not sold by Kinghome. *On a Defrost signal, 24volts is sent from the outdoor unit from D terminal to W at the furnace, once the temperature limit is reach, the 24volts signal will be cut off. This option will allow anti- cold draft air in the room and prevent the heat pump to reach a high-pressure switch error (E1) or the compressor to resume it operation.
Page 7
Schematic with Air Handler/Duct Heater Note: During Defrost cycle, D terminal from the outdoor unit apply 24volts to D terminal at the indoor air handler, this signal will allow the indoor fan to stop to avoid cold draft air in the room. Kinghome Canda...
Page 8
Note: During Defrost cycle, D terminal from the outdoor unit apply 24volts to W terminal at the indoor air handler, this signal will allow the duct heater to start and provide warm temperature in the room during the defrost cycle. Kinghome Canda...
Configuration WK-010WC1 All configurations must be executed under ‘’OFF Mode’’ Click MENU and select INSTALLER SETUP (press SET to enter) Parameter Range Remarks Thermostat Set Reserved Fixed to ‘’Primary’’ Communication 24V/RS485 Version 1.0 using 24V communication mode. Outdoor unit type...
Page 10
Configuration WK-010WC1 Air Handler configuration only. *(W2/AUX) output terminal. Parameter Range Remarks AUX on Timer 0~120min AUX will be active after the selected time value. Max Activate Temp 10~30°C AUX disable when over the selected for AUX 50~86°F temperature value.
Page 11
Configuration WK-010WC1 Dual fuel configuration only. *(W) output terminal. Parameter Range Remarks Dual fuel Switch -25~15°C Over set temp value, HP is disabled, ODU Temp -13~59°F and Fur is activated. Dual fuel Switch 10~120min When HP active > set time value, HP Timer is disabled, and Fur is activated.
Page 12
Configuration WK-010WC1 Air Handler/Gas Furnace configuration. Parameter Range Remarks Temp Display -3~3°C Adjust Temp display to room -10~10°F temperature. (Default is 0°) Cool Swing 2~4°C Set point differential under AUTO mode 4~8°F only. Heat Swing 2~4°C Set point differential under AUTO mode 4~8°F...
Page 13
*Outdoor sensor is optional, if needed connect to S1/S2 with a 15 kohms thermistor otherwise the outdoor temperature will show 32°F (0°C). *Smart mode: The system will use the Kinghome algorithm once connect via WIFI. Outdoor temperature will be provided by the weather channel in your area via the postal code.
Schedule WK-010WC1 Create or Edit a schedule with the thermostat. Under Mode OFF, click and hold the to enter de schedule function button #2 function. Then, selected the require time mode. Kinghome Canda...
Page 15
Schedule WK-010WC1 7 Day = Create a schedule for every single day of the week. 5-2 = Create a schedule base on weekday and weekend. 1 Week = Create a schedule for 7 days of a week. Adjust Time and Temperature accordingly to your preferences in heating and cooling.
Page 16
Schedule WK-010WC1 To activate the schedule, go back to the main screen. Under Cool, Heat or AUX Heat, press the once Function button #2 Week Sched. will appear on the screen. It means that the schedule function is ready. Kinghome Canda...
Page 17
Schedule WK-010WC1 When Wake, Leave, Return or Sleep appear on the screen, it means the temperature set point has change to the pre-set temperature following the schedule. Note: If no schedule is desire, make sure the Week Sched. disappear from the screen by touching function button #2 once.
Page 18
3: Touch screen thermostat via the Kinghome + APP 4: Master thermostat via the Kinghome + APP The version 1.00 of the WK-010WC1 cannot communicate the schedule from one device to another device. The system will run the last command received from the latest schedule if multiple schedules is involved.
Page 19
WiFi Function Setting "Kinghome +" App can be used to control thermostat. When "Kinghome +" App is installed, register the account and add the device to achieve long- distance control and LAN control of Kinghome smart home appliances. When using the App for the first time, please reset WiFi of thermostat at first (reset WiFi to factory setting).
Page 20
WiFi Function Setting Follow the step-by-step process to create an account on Kinghome + app. Once created, click on the + sign (top corner right) to find available WIFI unit near you. The touchscreen thermostat and master thermostat are WIFI compatible, choose one device ID to configure.
Page 21
WiFi Function Setting Confirm your home WIFI name/password to connect with the thermostat. Kinghome Cloud will communicate with your device. Wait till the process if finished. Kinghome Canda...
Page 22
You can click the 3 dots in the upper right corner and select Device Details to rename the Device name. *Scroll up the bottom arrow to access more adjustment from the app. *SmartCrl Heat Sources Usage Report is only available when you have paired the Touchscreen Thermostat. Kinghome Canda...
Configuration WK-010WD1 All configurations must be executed under ‘’OFF Mode’’ Click FUNCTION select INSTALLATION PARAMETERS The touch screen thermostat uses the same installation parameter than the master thermostat, use the slider button to adjust the desired setting. Kinghome Canda...
field environment. *Use micro lead to take the reading. Check 24VAC power from the furnace/air handler on R-C Terminal. Check H1/H2 terminal on the thermostat a pulsating value from (-5VDC ~ 5VDC). Kinghome Canda...
Page 25
C and W = 24VAC C and G = 24VAC Call for AUX heat, using the air handler. Check for 24VAC on Terminal W and G Check Terminals C and W2/AUX = 24VAC C and G = 24VAC Kinghome Canda...
Page 26
Check Terminals C and Hum = 24VAC Call for ERV (Fresh air option) • The ERV turn on when enable in the User Function Setting Check for 24VAC on Terminal ERV Check Terminals C and ERV = 24VAC Kinghome Canda...
Need help?