Operating instruction Remote control station WCM-FS 2.0 User instructions ........................4 User instructions ....................4 User guide ......................4 1.2.1 Symbols ......................... 4 1.2.2 Target group ......................4 Guarantee and Liability ..................4 Safety ............................5 Permissible application ..................5 Safety measures ....................
Page 3
Operating instruction Remote control station WCM-FS 2.0 Settings of end user level ................23 4.7.1 Call up info external min .................. 23 4.7.2 Call up info external max ................. 23 4.7.3 Call up info solar yield counter ..............24 4.7.4 Call up info total solar yield ................
Non approved application of the remote control station, ▪ non observance of the operating instructions, ▪ continual operation despite a fault, ▪ repairs, which have been carried out incorrectly, ▪ the use of non original Weishaupt parts, ▪ acts of God. 4-43 83277702 • 1/2012-04 • La...
2 Safety 2 Safety 2.1 Permissible application The remote control station WCM-FS 2.0 is suitable for the control of a heating system consisting of a Weishaupt condensing boiler combined with a solar system and solar controller WCM-SOL 1.0 home. Any use other than that described above shall be deemed improper. Weishaupt can- not be held responsible for any damage resulting from such use.
Remote control station WCM-FS 2.0 3 Product description 3 Product description The remote control station WCM-FS 2.0 is a control and operating device for WCM components, such as a Weishaupt condensing boiler in combination with a solar controller WCM-SOL 1.0 home.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4 Operation 4.1 Operating panel modul control 1 Dial knob Navigation through levels and parameters, change values, switch on illumination. 2 Function keys 1 … 4 Used to activate functions. 3 Presence and absence key Used for short term interruption or extension of the heating program.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.2 Display Depending on the type of system, different features may be shown in the display. 4.2.1 Standard display Factory presetting Display of allocated factory pre-settings (standard). 21.May 07 19:20 Room temp.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.2.2 Setting level standard display Normal room temp 22.0°C 22.0°C Standard 15.0°C - 30.0°C 1 Display function key 1 End Abort setting procedure without saving and exit level 2 Display function key 2, if applicable special functions e.g. Holiday , DHW Boost …...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.3 Settings in the standard display 4.3.1 Set DHW setpoint The water tap symbol is only available on systems with DHW operation. In the standard display, the Normal DHW-Set can only be changed in normal DHW operation and the Setback DHW-Set can only be changed in DHW setback op- eration.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.3.2 Display general information In the standard display, the time bar 1 shows the heating program currently active (HC = heating circuit or DHW = DHW load circuit). By repeatedly pressing function key 2 i , the current actual values of the heating system are displayed one by one.
Page 12
Operating instruction Remote control station WCM-FS 2.0 4 Operation Status information of the heating circuit: Additional functions activated Status#... Screed Screed function Service Chimney sweep function is carried out on the heat exchanger. Heat consumption due to excess solar SOL-Excess temp temperature.
Page 13
Operating instruction Remote control station WCM-FS 2.0 4 Operation The following display appears only when using the solar controller WCM-SOL 1.0 home. Temperature of the collector Collector …°C Temperature when lowering Solar bottom …°C Today's solar yield Yield …kWh Status information of the solar circuit:...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.3.3 Set room temperature The display differs according to the type of operation and setting selected by the heating engineer. Type of operation Symbol Display Normal room temp Normal Normal supply setpoint Normal room temp Heating program 1 …...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.3.4 Select type of operation Menus and parameters are shown or hidden depending on the system variation. Type of operation No heating or DHW operation. Standby Frost protection is activated. Heating program 1 Heating program 1 …...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.4 Presence and absence function Using the presence and absence function, the heating program can be extended or interrupted for a short period of time. This function is only possible in type of operation heating program 1 ... 3.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.4.3 Setting the effectiveness duration Settings: ▪ from current time, ▪ to next heating cycle change-over. From setback level to heating phase ▶ Press and hold presence and absence key for approx. 1.5 seconds.
Page 18
Operating instruction Remote control station WCM-FS 2.0 4 Operation From heating phase to setback level ▶ Save entry using function key OK . ✓ The timer bar decreases in length according to the time set. Absence and symbol Moon are displayed.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.5 Activating end user level Activate end user level ▶ Briefly press menu key in the standard display. ✓ End user level is displayed. End user Info Remote control Setting #1...
Page 20
Operating instruction Remote control station WCM-FS 2.0 4 Operation Selecting and setting parameters ▶ Select parameter and press the relevant function key. ✓ Parameter is displayed. ▶ Make a selection using the dial knob and save setting with function key OK .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.6 Menu structure end user level Menu points and parameters are hidden or displayed according to the settings made in the heating engineer level. Menu point Parameters Description Factory pre- setting...
Page 22
Operating instruction Remote control station WCM-FS 2.0 4 Operation Menu point Parameters Description Factory pre- setting Date (see Ch. 4.7.23) – Time-Date Time (see Ch. 4.7.23) – Summertime start 25.Mar (see Ch. 4.7.23) Summertime end 25.Oct (see Ch. 4.7.23) Time program Heating program 1 –...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7 Settings of end user level 4.7.1 Call up info external min ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Info . ✓ Menu Info is displayed.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.3 Call up info solar yield counter ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Info . ✓ Menu Info is displayed. ▶ Press function key Yield counter .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.4 Call up info total solar yield ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Info . ✓ Menu Info is displayed. ▶ Use dial knob to move to the second menu level.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.5 Call up info solar statistic Display of solar yields and ope5rating times of the last 14 days. ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Info .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.6 Setting room sensor correction The room sensor can be adapted to an existing thermometer. ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Remote control . ✓...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.8 Set brightness ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Remote control . ✓ Menu Remote control is displayed. ▶ Press function key Illumination . ✓...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.10 Set setback room temperature ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Setting #1 . ✓ Menu Settings #1 is displayed. ▶ Press function key Setback room temp .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.12 Set setback supply temperature setpoint ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Setting #1 . ✓ Menu Settings #1 is displayed. ▶ Press function key Setback supply set .
"Acceptance room" set here. The mixer tries to continue the control to the room temperature setpoint set. For this function, the room sensor of the WCM-FS 2.0 is evaluated, this assumes that the FS is installed at a suitable location.
Page 32
Operating instruction Remote control station WCM-FS 2.0 4 Operation A change in the normal room temperature or setback room temperature leads to a parallel translation of the set rate of rise. In cold weather, the room temperature is too cold.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.15 Set room frost protection temperature The parameter room frost temperature has a direct effect on the supply tempera- ture. The temperature set is not the actual room temperature during frost protection. The difference is negligible if the gradient has been set correctly.
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.17 Set normal DHW temperature ▶ Activate end user level (see Ch. 4.5). ▶ Press function key DHW . ✓ Menu DHW is displayed. ▶ Press function key Normal DHW set .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.19 Set acceptance DHW If the current solar yield is sufficient, this parameter can be set to save fossil fuel. From a particular yield level which is set in the WCM-Sol, DHW reheating by the WTC is blocked, until the DHW temperature falls below the DHW temperature setpoint minus the "Acceptance DHW"...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.21 Set temperature level ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Holiday . ✓ Menu Holiday is displayed. ▶ Press function key Temp level . ✓...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.23 Set date, time and summer time change-over The parameter is only displayed in the remote control station, which is addressed with Control centre #L , WTC-HC#1 , EM-HC#2 or WTC-HC#1 +EM-HC#2 .
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.24 Call up time program ▶ Activate end user level (see Ch. 4.5). ▶ Press function key Time program . ✓ Menu Time program is displayed. ▶ Press function key Heat program1 .
Operating instruction Remote control station WCM-FS 2.0 4 Operation Factory presetting time program Heating program 1 Mon - Fri 06:00 - 22:00 Sat - Sun 07:00 - 23:00 Heating program 2 06:00 - 08:00 Mon - Fri 16:00 - 22:00...
Operating instruction Remote control station WCM-FS 2.0 4 Operation 4.7.27 Set WCM-EM without WCM-FS assigned It is possible to operate several extension modules via one remote control station. In menu point Access HC w.o. FS all extension modules without WCM-FS assigned are listed, and can be set via this menu point.
Page 42
Operating instruction Remote control station WCM-FS 2.0 4 Operation Find extension modules without WCM-FS assigned If no or not all extension modules are displayed a new configuration must be carried out. ▶ Press function key new config . ✓ Message search config is displayed briefly, then the list of extension modules without remote control station assigned reappears.
Operating instruction Remote control station WCM-FS 2.0 5 Key word index Presence and absence key ..........7 Pre-setting HC#2 ...............40 Contrast ................27 Room frost temperature ............33 Date ..................37 Room sensor correction ............27 DHW ................34, 35 Room temperature ........14, 28, 29, 32 DHW boost function ............10...
Page 44
Change of legal form from 22.11.2024: Max Weishaupt SE Change of legal form from 22.11.2024: Max Weishaupt SE www.weishaupt.de Max Weishaupt GmbH, D-88475 Schwendi Weishaupt (UK) Limited Neachells Lane, Willenhall, WV13 3RG www.weishaupt.co.uk Printed in Germany. All rights reserved. Product...
Need help?
Do you have a question about the WCM-FS 2.0 and is the answer not in the manual?
Questions and answers