Test Programme; Procedure For Diagnostic Service Test Programme - Whirlpool 6ADP2956 IXM Service Manual

Table of Contents

Advertisement

WHIRLPOOL CONSUMER SERVICES

TEST PROGRAMME

To start the passive test programme :
1. Turn the programme selector to OFF
2. Hold the start button in and at the same time turn the programme selector to the first cycle
(40°C-55°C Normal). Wait until the light behind the start button begins to flash then
release the start button.
3. The four programme progress lights in the display panel will flash sequentially from left to
right. This indicates that the microprocessor is serviceable.
If there is a component failure, the light behind the start button will flash as indicated in the
table below to indicate the area to check.
Failure
Sensor failure
NTC failure
Water leakage
Heating system
Drain system
Water inlet closed
Flow meter
Water level
Continuous water fill
Rinse aid low
NOTE: The machine will not store Fault Code F6 located during normal operation, only
during the active test. Therefore the active test MUST be run for the diagnostics
to locate this fault. All Other Fault codes located during normal operation are
stored by the machine and will be displayed by the passive test.

PROCEDURE FOR DIAGNOSTIC SERVICE TEST PROGRAMME

1.
Start the passive test programme. (See Page 15).
If there is a defective component indicated (see Note 2), open the plinth and take out
the control board (CB).
2.
Check the component.
Unplug the indicated component from the control board and check with a multimeter. If
the component resistance is comparable with the data sheet, check cabling and
connections and examine the component.
3.
Check control board.
Dishwasher components are controlled via electronic devices. As a result, when
checking component control board output voltages, the component connector must be
connected to the control board to load the electronic device.
4.
If the dishwasher appears totally dead, perform test point tests. (See Page 19).
Failure
Indication
No.
F0
Start button lamp flashes ten times, one sec break, repeat
F1
Start button lamp flashes once, one sec break, repeat
F2
Start button lamp flashes twice, one sec break, repeat
F3
Start button lamp flashes three times, one sec break, repeat
F4
Start button lamp flashes four times, one sec break, repeat
F6
Start button lamp flashes five times, one sec break, repeat
F7
Start button lamp flashes seven times, one sec break, repeat
F8
Start button lamp flashes eight times, one sec break, repeat
F9
Start button lamp flashes nine times, one sec break, repeat
-
Red light on (This does not prevent the machine from operating)