Advertisement

VEWIOR V02 Manual

YOUR HUMIDIFIER

Welcome to VEWIOR family! We wish you to enjoy using this product.

  1. Original patent, PCBA top, LED water tank upper surface back lighting;
  2. Original patent. Atomizer and water tank isolation ensures constant high and low water level mist release;
  3. Original patent. The spray chamber unit is placed in the water tank, the water will not spill out of the machine, avoiding the disadvantages of the conventional water humidifier;
  4. Special ring energy plate structure, mist high release level.

SPECIFICATIONS

Input: AC100-240V 50/60Hz
Rated: 18W
Won't Leak
Auto shut-off, anti-dry protection
Output: 24V 750mA
Product Weight: 1037g
Product Size: 234.5*184*316.5mm
Operating Temperature: 10-40 ºC
Type: Ultrasonic
Please use water-soluble essential oil
Tank Capacity: 6.5L (MAX)

The above specification may vary due to product upgrades.

PACKAGE CONTENTS

PRODUCT OVERVIEW

PRODUCT OVERVIEW

BEFORE USING

After unboxing the packaging please check if all the components are in place. Remove the Motherboard to take out all accessories in the water tank, then assemble the humidifier.
BEFORE USING

USE THE HUMIDIFIER CORRECTLY

  1. Place humidifier on a solid and even surface, then you can pour water from top directly.
    USE THE HUMIDIFIER CORRECTLY - Step 1
  2. DO NOT fill water from the mist outlet on the top of the humidifier, otherwise the humidifier will not work for a while until the water in the air outlet enter the water tank.
    USE THE HUMIDIFIER CORRECTLY - Step 2
  3. You can also remove the Motherboard directly, then fill the tank with water.
    USE THE HUMIDIFIER CORRECTLY - Step 3
  4. Do not exceed the max capacity mark.
    (warningAttention: The max and min water line is inside the water tank.)
    USE THE HUMIDIFIER CORRECTLY - Step 4
  1. Add essential oils into the water tank to enjoy the aromatherapy.
  1. Place the Motherboard into the water tank. Ensure all the components are fixed securely. Connect the power supply and turn the appliance on.

FUNCTIONS

* Important Notes

  1. The default speed is "H"(the highest).
  2. The "H", "M", and "L" buttons are mainly used to show the speed state. Not for speed control directly.
  3. The power button " " is the only valid button. Please press the power button to adjust the mode that you need.
  4. When the humidifier has no water, the blue atmosphere light will flash for 3 seconds then the humidifier will shut down automatically

Speed Mode Function
The humidifier has three speed modes as follows.
H -the highest speed
M -the middle speed
L--the intermittent mode

  1. Plug the DC24V power cable and touch the power button to turn the humidifier on. (The default speed "H" starts at the same time. The LED Light shows "H")
  2. Touch the power button "" to change the speed to "M" from "H". (The LED Light shows "H""M")
  3. Touch the power button "" to change the speed to "L" from "M". (The LED Light shows "M""L")

Atmosphere Light Function

  1. Long touch the power button for 2 seconds to turn on the atmosphere light.
  2. Long touch the power button for 2 seconds to turn off the atmosphere light.

How to turn off the humidifier?

  1. lf your humidifier is on the "H" mode, please touch the power button "" three times. (The LED Light shows "H""M""L"off)
  2. If your humidifier is on the "M" mode, please touch the power button "" two times. (The LED Light shows "M""L"off)
  3. If your humidifier is on the "L" mode, please touch the power button "" one time. (The LED Light shows "L"off)

Tip: When the humidifier was turned off, the fan will still work for 30 seconds to blow away the residual fog in the water tank.

TIPS AND MAINTENANCE

  1. VEWIOR humidifier is designed to be cleaned in an easy way. Please regularly clean the water tank, spray chamber unit cover, atomizer, and internal parts which are in direct contact with water.
  • Turn off and unplug the humidifier before cleaning.
  • Pour out the water from the water tank and spray chamber unit cover completely.
  • Add some clean water to the unit.
  • Clean the ultrasonic energy plate with a soft brush (cotton swab).
    Wipe the water tank, spray chamber unit cover, silicone valve, float, and other internal parts with a soft cloth. Empty the water tank into a sink. Clean the unit with clean water 2-3 times, and carefully pour the water away.
  • Dilute a small amount of kitchen detergent in warm water, wipe the unit shell with a soft rag, and then wipe it with clean water.
  • Clean air inlets with a soft brush (cotton swab).
  • When maintaining, do not use medical dilute agent phenyl ethanol, otherwise, it will damage the screen printing logo;
  • When not in use for a long time, clean it, dry it and store it in the original packaging in a well-ventilated and dry place.
  1. Please change the water in the water tank frequently and pour the water correctly. Please do not add water directly through the mist outlet as the water may accidentally enter the fan and PCBA and damage the humidifier. Remove the spray chamber unit cover according to the instructions, and empty the spray chamber unit cover.
  2. When cleaning, please pay attention not to let the water enter the mist outlet; During operating and maintenance, it is forbidden to reverse or tilt the motherboard to avoid short-circuit caused by water entering the fan and PCBA.
  3. Please don't put the spray chamber unit upside down to avoid water backflow to the motherboard and damage to the function.
  4. Do not exceed the max capacity mark.
  1. When water runs out, the VEWIOR humidifier turns off automatically. The water left in the water tank (not totally dried) prevents dry burn.
  2. Due to a top-filled design, mist output may be affected by the current water level. If the filled water is poor quality or the water in the tank is dirty, the humidifier may not operate even when the water level is enough. Please empty the water tank, and clean the unit and its components. Dry the unit before using it again after reinstallation, it will return to its normal state.

ASSEMBLY / DISASSEMBLY

ASSEMBLY / DISASSEMBLY

SAFETY PRECAUTIONS

  1. lf the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  2. Unplug the unit when filling the water or cleaning.
  3. Do not use acid, alkaline and other corrosive liquids when cleaning the humidifier. Alcohol, water and other neutral liquids must be used for cleaning and maintenance.
  4. Recommended humidifier operating ambient temperature: 10-40 ºC, relative humidity is less than 80%RH. The temperature of water must not exceed 40 ºC.
  5. After use, please empty the tank to avoid bacteria breeding.
  6. The atomizing unit is strictly prohibited from scraping to avoid damage;
  7. Do not place the power adapter in water, wet place or moist conditions to prevent electric shock.

CUSTOMER SERVICE
We are committed to providing you with the best quality and service. VEWIOR offers a 1-year warranty + 30 days return/exchange policy + lifetime support for this product.
If you have any questions or feedback, please contact our customer support team at
1 -888-285-6061
support@vewiorlife.com
www.vewiorlife.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download VEWIOR V02 Manual

Advertisement

Need help?

Need help?

Do you have a question about the V02 and is the answer not in the manual?

Questions and answers

Table of Contents