Rugged PCB type
LDA10F
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
SPECIFICATIONS
MODEL
VOLTAGE[V]
LDA
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%]
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV] 50max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
OUTPUT VOLTAGE SETTING[V] xx
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00V min
PROTECTION
CIRCUIT AND
OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
ISOLATION
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +60 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ) 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ) 9 , 000m ( 30 , 000feet ) max
ENVIRONMENT
VIBRATION
IMPACT
SAFETY AND
AGENCY APPROVALS
NOISE
CONDUCTED NOISE
REGULATIONS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*
Avoid prolonged use under over-load.
*
Series/Parallel operation with other model is not possible.
*
Derating is required when operated with chassis and cover.
=marked models are pending for safety approvals. Consult with us for delivery.
D-26
LDA10F-3
LDA10F-5
6
10
3V 2.0A
5V 2.0A
= LDA10F-3
LDA10F-5
AC85 - 264 1 f or DC110 - 370
ACIN 100V 0.25typ ( Io=100% )
ACIN 200V 0.16typ ( Io=100% )
47 - 440 or DC
68typ
72typ
ACIN 100V 15typ ( Io=100% ) ( At cold start )
ACIN 200V 30typ ( Io=100% ) ( At cold start )
0.75max ( 60Hz , According to UL , CSA , VDE and DEN-AN )
3
5
2
2
20max
20max
40max
40max
0 to +50 C 80max
80max
-10 - 0 C 140max
140max
0 to +50 C 120max
120max
-10 - 0 C 160max
160max
50max
* 1
20max
20max
200max ( ACIN 100V , Io=100% )
10typ ( ACIN 85V , Io=100% ) 20typ ( ACIN 100V , Io=100% ) 100typ ( ACIN 200V , Io=100% )
Fixed ( "Y"which can be adjusted the output is available as option :5 - 24V t 10% )
4.9 - 5.3
Works over 115% of rating , by zener diode clamping
Not provided
Not provided
Not provided
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
2
( 20G ), 11ms , once each X , Y and Z axis
196.1m/s
2
UL1950 , EN60950 , VDE0160 , CSA C22.2 No.234 Complies with DEN-AN and IEC60950
Complies with FCC-B , CISPR22-B , EN55022-B , VCCI-B
50 X 21 X 105mm ( W X H X D ) /75g max ( without chassis and cover )
Convection
Ordering information
LDA
10
F
1
2
3
LDA10F-12
LDA10F-15
10.8
10.5
12V 0.9A
15V 0.7A
LDA10F-12
LDA10F-15
74typ
74typ
12
15
0.9
0.7
48max
60max
100max
120max
120max
120max
160max
160max
150max
150max
180max
180max
120max
150max
48max
60max
11.5 - 12.5
14.4 - 15.6
-5
-O
4
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
LDA10F-24
12
24V 0.5A
LDA10F-24
78typ
24
0.5
96max
150max
120max
160max
150max
180max
240max
96max
23.0 - 25.0