  • Page 1 Optometer (X1-1, X1-2 and X1-5) Gigahertz-Optik GmbH ● An der Kälberweide 12 ● D-82299 Türkenfeld ● Tel: + 49 / 8193 / 9 37 00 - 0 ● Fax: - 50 ● info@gigahertz-optik.com Gigahertz-Optik Inc. ● 110 Haverhill Road ● Amesbury MA 01913 USA ● Tel: +978.462.1818 ● Fax: +978.462.3677 ● b.angelo@gigahertz-optik.com...
  • Page 2: Table Of Contents

    1.8 CE Conformity declaration Page 4 1.9 Review clause Page 4 1.10 Contact details Page 4 1.11 Miscellaneous Page 4 2. X1 series…………………….…………….………………………………………………….…. Page 5 2.1 Intended use Page 5 2.2 Inspection Page 5 2.3 Technical specifications Page 6 2.4 Device description Page 7 2.4.1 General...
  • Page 3: General Information

    The responsibility for all consequences that might arise from the use of the device or its accessories lies solely on the user and/or owner. Gigahertz-Optik or its supplier can under no circumstances be liable for any direct or indirect business interruptions, loss •...
  • Page 4: Maintenance And Cleaning

    In order for the warranty to be effective, the customer should submit the product name, serial number, date of purchase as well as the description of the defect in writing to Gigahertz-Optik GmbH after which he/she will receive a service num- ber (RMA) enabling him/her to send back the device.
  • Page 5: X1 Series

    2. Device series X1 2.1 Intended use The X1 series is used for reading and displaying optical sensors When not in use, remove the batteries from the device. 2.2 Review Upon receipt of the device, please check its packaging for possible transport damage.
  • Page 6: Technical Specifications

    The device requires two AA batteries. If the battery voltage is too low, "Low Battery" is shown in the display. Do not work with the device again until the housing is completely and securely closed! X1 series / Page 6...
  • Page 7: Device Description

    USB (X1-1, X1-5) or Detector connector • Now you can adjust the corresponding measurement RS232 (X1-2) inter- settings with the help of the keys face • Press the center button to start a measurement Picture 7.2: X1 X1 series / Page 7...
  • Page 8: Manual Use

    If no detector is connected display shows “Err. Cal.-Data”. 4. Offset performs an automatic offset adjustment ("Offset = CW" or "Offset = 0") 5. Range sets the measurement range (auto, manual) X1 series / Page 8...
  • Page 9: Remote Use

    Auto (for automatically range switching depending on the input signal) can be selected. 2.4.5 Interfaces Operation: See the documentation for the optional S-SDK-X1 Function USB (X1-1, X1-5) Function RS232 (X1-2 only) +5VDC Input +5VDC Input TxD (connect to RxD of PC) RxD (connect to TxD of PC) X1 series / Page 9...
  • Page 10: Miscellaneous

    •  Restart the device and repeat the measurement  Check the device initialization. If the error persists, please contact the Gigahertz-Optik support. You can alternatively send the device with its accessories to Gigahertz-Optik for review. • The device does not power on ...