Norden NVS-IP100006AM User Manual

Ip based power amplifier

Advertisement

Quick Links

NVS-IP100006AM/NVS-IP100007AM/
NVS-IP100008AM/NVS-IP100009AM
IP Based Power Amplifier
User Manual
www.nordencommunication.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NVS-IP100006AM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Norden NVS-IP100006AM

  • Page 1 NVS-IP100006AM/NVS-IP100007AM/ NVS-IP100008AM/NVS-IP100009AM IP Based Power Amplifier User Manual www.nordencommunication.com...
  • Page 2 www.nordencommunication.com...
  • Page 3: Table Of Contents

    Contents Product Overview....................03 • Description......................03 • Features......................03 Hardware Interface Introduction………..............04 • Front Panel......................04 • Rear Panel......................04 Introduction…………………………………………………………………………………………………………06 • Wiring.......................06 Network Settings…………………………………………………………………………………………………06 • Basic Network Settings…………………………………………………………………………………06 ➢ IP Device Configuration Tool………………………………………………………………06 ➢ Through Web Interface………………………………………………………………………07 Terminal Parameters Customization…………………………………………………………………….08 • Web Interface Login……………………………………………………………………………………..08 •...
  • Page 4: Product Overview

    • SIP protocol compatibility for easy integration with mainstream VoIP systems (Yeastar, Asterisk, Cisco, etc.) • Supports offline broadcasting independently of a server. • Receives live voice announcements from third-party VoIP systems or NORDEN's centralized management software. • Relay I/O port for connecting with fire alarm systems.
  • Page 5: Hardware Interface Introduction

    Hardware Interface Introduction Front Panel 1. Power When the power is connected, red light keeps on. 2. Status Bi-coloured light, green light keeps on when the equipment is online, red light keeps flashing when the equipment is offline, greed light keeps flashing when receiving signals.
  • Page 6 3. ALARM OUT Alarm output interface (●-NC: Normally Closed;1-COM:COM;○-NO: Normally opened). 4. ALARM IN Alarm input interface (A: Alarm input;G: GND). 5. AUX1 Line input1 interface (Balance input) (H: Hot end,C: Cold end,E: Earth end). 6. MUTE Knob MUTE depth adjustment knob, when the MIC input signals, it’ll automatically MUTE AUX1 and AUX2, clockwise rotation will increase the MUTE depth, anticlockwise rotation will decrease the MUTE depth.
  • Page 7: Introduction

    Introduction Wiring (1) Connect one end of the power cord to the power interface of the IP based power amplifier, and the other end to the power socket. (2) Connect one end of the Ethernet cable to the network interface of the IP based power amplifier, and the other end to the switch.
  • Page 8: Through Web Interface

    2. Choose 【Mandatory Configuration】 from the menu on the right side, then fill in correct parameters in the 【Terminal Parameters】, click “send parameters” button to finish the IP parameters settings. Note: 1) If using Windows 7 system, please use the administrator mode to run the program, and close the firewall or other related software.
  • Page 9: Terminal Parameters Customization

    Terminal Parameters Customization Web Interface Login Enter the IP address (Factory Default IP is 192.168.1.101) of the IP based power amplifier in the browser address bar, then press the Enter key. Enter the username and password to log in. Note: Default username and password are both admin. Press login to enter IP based power amplifier web page.
  • Page 10: Network Parameters

    Network Parameters Please set the terminal’s network parameters according to the environment of the terminal. Click [save] after setting, the parameters will take effect after reboot. The relevant Settings of network parameters are as follows: Supports static IP or DHCP IP address assignment. Static IP: Default static IP, user-defined IP address and other Link type information...
  • Page 11: Server Parameters

    The IP address of the preferred DNS server (domain name Primary DNS resolver) for the network. Secondary The IP address of the alternate DNS server (domain name resolver) for the network. Server Parameters IP based power amplifier support with SIP protocol and NAS protocol, you can choose the transport protocol based on the actual server you log in to.
  • Page 12: Nas Protocol

    IP address of the SIP server that the terminal logs into. Please Sip Server IP, enter the correct IP address of the SIP server. The port port number cannot be changed except in special cases. (Default is 5060) Unique number to identify the terminal and cannot be Terminal ID duplicated with terminals or other hosts.
  • Page 13: Audio Parameters

    Transport Setting the protocol for normal communication between Protocol device and server. Unique number to identify the terminal and cannot be Terminal ID duplicated with terminals or other hosts. Configure the local port according to the actual situation; the Local port default is 5060.
  • Page 14 The relevant Settings are as follows: Offline Set the Offline Broadcast Volume, configuration range from 0 Broadcast to 15. Volume Line Input Set line input sensitivity, the default is 1.15V. Sensitivity Volume balance, low sound will compensate, high sound will Line Input ACC suppress, the value set is the maximum value for compensation.
  • Page 15 Power Amplifier The default is constant voltage 100V output, and it is Output supported to be set to constant voltage 70V output. Audio check means loop detection function. After enabling the function, the device will play sound through built-in Audio Check microphone after receiving server tasks.
  • Page 16: Local Task Priority

    Power amplifier protection threshold: This value corresponds to the lowest audio frequency that the loudspeaker can accept. For special speakers or special scenes, just keep the default Slope value. The sound effect of current network task can be adjusted after enable the EQ.
  • Page 17: System Maintenance

    System Maintenance Reboot the device: Click on this button will reboot the device. Default: Click this button and all parameters of the device will be restored to factory Settings (please use with caution). Time to Restart After this function is enabled, you can set the time for restarting the device every day. The default value is disabled.
  • Page 18: Protocol Settings

    Protocol Settings ICMP: You are advised to disable ICMP when using the new IP configuration tool to configure network parameters. FTP: Set whether to enable FTP remote file transfer function. The default value is disable. TELNET: Set whether to enable the TELNET remote login function. The default value is disable.
  • Page 19: User Management

    User Management You can change the password for logging into the WEB on this page. After saving the password change, rebooting the web page to take effect. www.nordencommunication.com...
  • Page 20: Upgrade

    Upgrade Click the "Upgrade" button, you will enter the firmware upgrade mode after 15 seconds. Click on "Browser", select the upgrade file provided by the manufacturer, and click "Upgrade" to start the upgrade. Note: Do not power off during the upgrade process, otherwise the upgrade may fail, and the device fails.
  • Page 21: Basic Functions

    Basic Functions Broadcast Supporting local broadcasting, terminal broadcasting, and server broadcasting. Offline Broadcast IP based power amplifier supports offline broadcast, when the device is offline, the offline task set by the server can be played regularly. The offline broadcast setting method is as followed: Server Setting Method: Add the "regular ringing"...
  • Page 22: Internal Communication Server Setting Method

    Note: offline broadcast only supports MP3 format audio. Internal communication server setting method: Firstly, set the task of "regular ringing " in the service software (please refer to user manual of software), and then click [operation] - [export]. Select the t task in the “Export timing tasks” list, and then click “OK”, tasks will be exported to USB root directory.
  • Page 23 Access to terminal FTP:// terminal IP (the defaults username and password is admin), put the exporting timing ring bell document to “NAS2007” under FTP (note: If there is no folder named as NAS2007, please crease a new one), It will be effective after reboot device.
  • Page 24: Trouble Shooting

    Trouble Shooting 1. No power? Why isn't the power indicator on? • Check whether the power plug is loose, and the power cord is in good condition. • Please check whether the power switch is on. • Please check whether the safety of the power socket is burned out. 2.

This manual is also suitable for:

Nvs-ip100007amNvs-ip100008amNvs-ip100009am

Table of Contents