TiEmme NG01 Hydro Manual

Control board for pellet stove
Table of Contents

Advertisement

Quick Links

NG01_Hydro
Control board for Pellet Stove
FW
Revision
Revision
Date
3.7
18/03/2022
3.6
23/12/2021
23/07/2021
11/05/2021
20/04/2021
24/02/2021
11/11/2020
23/09/2020
12/05/2020
18/12/2019
12/11/2019
18/07/2019
20/05/2019
06/02/2019
24/01/2019
Management change of the Auger Regulation by the Primary Air Controller 6.4.9
On-Off Pump Operation
The operation of the Primary Air Regulator has been modified
Primary Air Regulator Management has been added in Ignition and
Stabilization
Management of DAC/PWM outputs has been added.
LCD100 and LCD100 touch panels will no more be updated since the
current firmware revision of the control board (3.0).
The parameter A99 has been added for the management of the ignition
Step
of the Igniter on a Triac output
TriKey and 2Ways2+ management has been added
The operation of the Pellet Level Sensor has been modified
Flow switch input logic inversion has been inserted
Soft Mode function has been modified
The label has been modified in Modulation for exhaust flue gas
temperature
Parameter P08 (Recipe) has been added to System Menu
Secondary Information have been modified
Soft Mode function has been added
Auger 2 pause-work has been added
Cleaning motor 4 has been added
Periodic Cleaning for recipe has been added
Auger feeding at the end of the extinguishing has been added
Keyboards K500 management has been added
Refill Function has been added
Minimum Flow Function Added
Language set 3 has been added
Language set 2 has been added
Hydraulic Plants 1, 3, 4, 6 have been added
Night Mode
Page 1 / 56
Description
DMANS03000002-NG01 HYDRO ENG Manual .docx
Hydro
6.14.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NG01 Hydro and is the answer not in the manual?

Questions and answers

Summary of Contents for TiEmme NG01 Hydro

  • Page 1 Minimum Flow Function Added 20/05/2019 • Language set 3 has been added 06/02/2019 • Language set 2 has been added • Hydraulic Plants 1, 3, 4, 6 have been added 24/01/2019 • Night Mode Page 1 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 2: Table Of Contents

    .................................. 32 RADIO CONTROL ..................................... 32 ODEM ................................. 33 OMBUSTION ANAGEMENT 6.3.1 Room Thermostat ................................33 6.3.2 Combustion Fan Speed ..............................33 6.3.3 Auger Speed ..................................33 6.3.4 Combustion Standby ............................... 33 Page 2 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 3 (TP05) ................................. 51 IMERS (TP08) ................................52 ETTINGS (TP11) ................................53 OUNTERS (TP12) ............................... 54 UTPUTS (TP16) ............................54 RIMARY EGULATOR 2 (TP25) ..............................55 OMBUSTION (TP26) ............................56 ESTORE EFAULT ALUE Page 3 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 4 This manual has been produced with care and attention, however the information could be incomplete, not comprehensive or contain mistakes. For this reason design, specifications and contents could be modified without notice depending on the model produced. TiEmme elettronica is not responsible for the incomplete or not correct information TiEmme elettronica 06055 Marsciano (PG) Italy Tel.
  • Page 5: Firmware Code And Languages

    Set 1 Set 2 Set 3 English English English Portuguese Dutch Greek German Danish Latvian French Swedish Estonian Spanish Turkish Lithuanian Italian Czech Hungarian Polish Romanian Serbian Slovakian Croatian Russian Slovenian Bulgarian Page 5 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 6: Installation

    2 Installation Electrical wirings Page 6 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 7 ACR1 and ACR2 modules switch one or two Triac outputs in exchanging relays outputs. In case you need to supply the used charged, follow diagram 2 for connections , otherwise diagram 1. Diagram 1 Diagram 2 Page 7 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 8: Technical Specifications

    P82) RS232 RS232 Connector Programmer, KeyPro, Modem, PC Link RS485 RS485 Connector Connection to LCD keyboard, 4Heat Flat Cable CP keyboard link Only available on boards whose hardware includes PWM output. Page 8 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 9: Lcd And Kpanels Connections

    Use a line termination resistor, if more than one RS485 device is connected to the board. In order to do this, move to ON only the device-switch with the longest connection cable. Page 9 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 10: Trikey

    Disabled output √ Pellet Safety Valve √ Loading Motor √ Output under thermostat √ Combustion Fan 2 √ Heating Fan √ Air Valve √ Error Report √ Electro valve/ P2 Pump √ Page 10 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 11 √ √ — — Primary Air regulator — — √ √ External Chrono √ √ √ √ Auger Encoder Input √ — — — Water Pressure Sensor — — √ √ Page 11 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 12: Control Panel

    Access to User Menu 1/submenu, Access to User Menu 2 (push for 3 sec.), Save data Access to Visualizations Menu, Increase Access to Visualizations Menu, Decrease Function Function Room Thermostat/Remote Keyboard room External Chrono reached thermostat reached WINTER SUMMER Domestic Hot Water Demand Page 12 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 13: K400

    System Operation Leds System Operation Leds Room Thermostat/ Auger On V2 Output On Remote keyboard Room Thermostat reached Igniter On External Chrono reached DHW demand Pump On Lack of fuel in the tank Page 13 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 14: K500 Panels

    : main temperature, value code Function Click Long press Views / Menu Exit Ignition/ Extinguishing / Block Reset Thermostat (+) / data increase Pellet loading correction Modify combustion power / Data Backup Manual pellet loading Page 14 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 15: Cp120

    Safety Thermostat Intervention HV1: signalling even when the stove is off Er01 Er01 Intervention of the Safety Pressure Switch HV2: signalling with Combustion Fan On Er02 Er02 Extinguishing for exhaust flue gas temperature decrease Er03 Er03 Page 15 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 16: Messages

    Combustion recipe selected; it is shown only if is higher than 1 Recipe [nr] Water Water Pressure; it is displayed if an input has been set as water Pressure Sensor [mbar] Pressure Page 16 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 17: Menu

    The system includes three type of programming: Daily, Weekly, Weekend. After selecting the program of your choice: 11:15 V 09:30 • Select the programmed time clicking P6 or P4 (P5 or P4 00:00 00:00 for K100) 00:00 00:00 Page 17 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 18: User Menu 2

    –7÷7. The default value is 0. The menu is displayed only if = 1. Only for local control panel. Summer-Winter Menu to edit the functioning of the hydraulic system according to the season. Automatic Power Page 18 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 19: Menu For K500 Panels

    This menu allows you to modify the value of the DHW Thermostat. It is displayed if an input has been set as DHW/Buffer tank Probe and a hydraulic system including a DHW Buffer tank has been selected. Page 19 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 20 This Menu allows to set and enable the time slot to start and end the Night Mode. The programming of the time slots is similar to the one shown in the Chrono Menu. Page 20 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 21 –7÷7. The default value is 0. The menu is displayed only if = 1. Automatic Power This menu allows you to set combustion power in automatic mode only. If you set it, power change menus are no longer displayed. Page 21 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 22: User Menu2

    4.3.2 User menu2 Menu is accessed by simultaneously pressing the keys P3 and P4 for 3 seconds on CP110/CP115 keyboards, or by single click on the key K5 on CP120 keyboards Page 22 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 23 For the Off time, the segment on the top of the D2 display is turned - - - - Instructions For each program select the ON and OFF time. Description Display Page 23 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 24 P3 or K5, the lower display shows , the upper one shows the elapsed loading time. Press the key P1 or K1 to stop the loading. The function will stop automatically after 300 seconds. Page 24 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 25 P05/2. The system must be into Off to carry out the measurement. System Menu (TPAr) Menu to enter into technical menu. The access is protected by a password (default password: 0000) Page 25 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 26: Operating States

    During the phase the exhaust temperature minimum value is saved by system Parameters Controls Combustion Fan Auger Igniter If Exhaust flue gas Temperature > Th09 → It goes into Run Mode I Ignition: I Ignition: Page 26 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 27: Stabilization

    Exhaust flue gas temperature < Th01 → Final Cleaning timer starts Max Speed Control upon the If Exhaust flue gas temperature < Th01 → It goes into Check Up Expiry of Page 27 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 28 Auger feeding Parameters Controls Combustion Fan Auger Igniter Exhaust flue gas t. < Th01 Thermostat → The timer starts Always ON Page 28 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 29: Run Mode

    → It goes into Standby Summer Mode If buffer tank temperature > Buffer tank Thermostat → It goes into Standby Th58 In Summer Mode, if there isn’t DHW demand → It goes into Standby Page 29 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 30: Standby

    Auger Igniter Extinguishing of the combustion. At the end the Work phase starts Work Phase Parameters Controls Combustion Fan Auger Igniter Reactivated combustion. Upon the expiry of the Pause phase starts Page 30 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 31: Safety

    → goes into OFF with no error, otherwise goes into Block expiring of Auger feeding Parameters Controls Combustion Fan Auger Igniter exhaust flue gas t. < Th01 Thermostat → The Timer starts Always ON Page 31 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 32: Functions

    Reset It allows you to unlock the system The status name in the SMS sent by the modem is: System State System State Page32 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 33: Combustion Management

    When the system comes out of Ignition to go into Run Mode, the Combustion Power, starting from Power 1, goes to operating power increasing its value with the delay time same as T18. Page33 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 34: Pellet Loading Correction

    If there is domestic hot water demand and the Pump is used also for DHW, the Room thermostat will not block it. = 1, 2, 3, 4, 5 if you don't use the input short-circuit pins. Page34 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 35: Flow Switch

    = 1, 2, 3, 4, 5 if you don't use the input short-circuit pins. 6.4.9 Primary Air Regulator The Regulator reads the air flow speed in the suction pipe of the stove/boiler. Page35 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 36 > 0 is decreased up to the set value minus the percentage value P148 (P27 remains the lower limit anyway) Air speed detection higher than the defined range • The combustion fan speed is decreased from the value up to the value Page36 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 37: External Chrono

    The contact is set as Exterior Chrono: when the contact closes the system goes into Ignition, when the contact opens it goes into Extinguishing. 6.4.11 Auger Encoder Input Use the input if you have an Encoder Auger. Connections: Sensor uIN2 pin 32 Page37 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 38: Water Pressure Sensor

    110 ÷ 134 135 ÷ 159 ≥ 160 temperature °C Heating Power Power 1 Power 2 Power 3 Power 4 Power 5 6.5.6 Air Valve The output is on if Combustion Fan is on. Page38 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 39: Errors Signaller

    Phase 1, otherwise the Cleaning function is over 6.5.12 Cleaning Motor 4 The output is on during the periodic cleaning of the brazier, in Check Up and during the final cleaning of the states Extinguishing, Standby and Recover Ignition. Page39 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 40: Auger Voltage Supply In Pwm

    • Recover status mode 0 (A53 = 0) If the power supply lacked for less than the system returns to its previous state Page40 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 41: Fast Extinguishing Function

    P1 Pump T < 5°C plant (OFF) 5°C ≤ T< 30°C plant (OFF) 30°C ≤ T< 40°C recirculation (ON) WINTER plant (OFF) open 40°C ≤ T< 70°C SUMMER recirculation (ON) closed recirculation (ON) Page41 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 42 Probe S2 Temp. Mode Differential P2 Valve P1 Pump T < 5°C plant (OFF) T > 55°C WINTER plant (OFF) WINTER recirculation T < 55°C 5°C ≤ T< 50°C (ON) SUMMER recirculation (ON) Page42 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 43 ≥ 5°C 65°C ≤ T< 70°C WINTER T > 55°C SUMMER < 5°C SUMMER ≥ 5°C T≥70°C CONFIGURATION 4 Setting the parameter = 4 it is chosen the configuration shown in pic.7. Page43 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 44 Th18. Example Th18 = 5 °C, Th19 = 40 °C, Th20 = 30 °C, Th21 = 70 °C Probe S1 Temp. Flow Switch Mode P1 Pump P2 Pump Page44 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 45: Pressure Sensor Selection

    Refill To enable the function enter again the menu and to disable it, set the value to 0. P111 = 0 the function is not available and related menus are not displayed. Page45 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 46: Soft Mode Function

    Duct Fan 2 (if present) If a parameter has been set to zero, the related output shall not work in Soft Mode. are different from zero, the primary air regulator shall be disabled. Page46 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 47: System Menu Parametrization (Tpar)

    (P05). To calculate the value, use the function 9999 Loading Test’ ‘ P118 Auger Off time in Unlock function Percentage variation of Auger speed/On time during the Periodic P193 * -100 Cleaning It changes with the combustion recipes Page47 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 48: Combustion Fan Menu (Tp02)

    Heating mode: 0 = manual/automatic; 1 = automatic only [nr] Exhaust Th05 Heating Fan Activation [°C] Flue Gas Exhaust flue gas temperature variation for automatic Exhaust [°C] regulation of the Heating Fan (P06 = 2) Flue Gas Page48 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 49 = 3) Delay on the activation at the maximum speed of the Heating Fan if exhaust flue gas temperature > thermostat Th07 Delay time changing heating power (used only if the power decreases) Page49 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 50: Thermostats Menu (Tp04)

    Hysteresis of the DHW Thermostat/Buffer tank DHW/Buffer [°C] Ih58 tank Hysteresis of the P2 Pump activation Thermostat (only if DHW/Buffer Ih59 [°C] = 4) tank Exhaust flue gas temperature increasing Delta in Exhaust Flue [°C] Stabilization Page50 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 51: Timers Menu (Tp05)

    Working time before the system goes into automatic Extinguishing 9600 [min] Maximum time for the opening of the Cleaning Motor limit switch Cleaning Motor work in Extinguishing, Recovery Ignition and 9600 Standby T87 * Cleaning Motor Pause time [min] Page51 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 52: Settings Menu (Tp08)

    DHW demand : 0 = the system does not go into Standby; 1 = [nr] the system goes into Standby Management of the key P3 or K5 from the control panel for the Pellet [nr] Manual Charge: 0 = enabled; 1 = disabled Page52 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 53: Counters Menu (Tp11)

    LCD and K100 panels menu is formed by 2 submenus, Counters and Error List. CP and K400 panels menu is only formed by the Counters menu. Counters Code Description LCD and K Ignitions * Co04 Number of attempted Ignitions Failed Ign. * Co05 Number of failed Ignitions Page53 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 54: Outputs Test Menu (Tp12)

    Auger speed for the calculation of the minimum and maximum range for the Auger regulation Stabilization time of the regulation on the first output Stabilization time of the regulation on the second output Waiting time for the first regulation Page54 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 55: Combustion Fan Menu 2 (Tp25)

    Speed in Ignition Pre-heating Decrease percentage of the Combustion Fan 2 speed compared with the values of power 5 if the Soft mode is On * It changes with the combustion recipes Page55 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...
  • Page 56: Restore Default Value Menu (Tp26)

    Restore Default Value Menu (TP26) This menu allows restoring the factory set value of the parameters used by the system. To use it, from software, the parameter ' Restore default values management' must be set to Page56 / 56 DMANS03000002-NG01 HYDRO ENG Manual .docx...