MuxLab 500791-V2 User Manual

Usb/ip ptz camera 12x zoom, poe

Advertisement

Quick Links

USB/IP PTZ Camera 12x Zoom, PoE
User Manual
500791-V2
© MuxLab Inc. 2024
1
94-001064-A/SE-001064-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 500791-V2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MuxLab 500791-V2

  • Page 1 USB/IP PTZ Camera 12x Zoom, PoE User Manual 500791-V2 © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 2: Table Of Contents

    11.10. Version................................19 12. Web Settings................................20 12.1. Control Camera............................21 12.2. Video Settings..............................22 12.3. Tracking.................................23 12.4. Image Settings.............................32 12.5. Audio Settings..............................33 12.6. System Settings............................33 12.7. Network Settings............................34 12.8. NDI Settings (Optional)..........................35 12.9. Overlay................................36 12.10. Device Information..........................36 13. Troubleshooting..............................37 © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 3: Safety Precautions

    All contents in this manual are copyrighted, and cannot be cloned, copied, or translated without the express permission of MuxLab Inc. Product specifications and information in this document are for reference only, and the content may be updated from time to time without prior notice.
  • Page 4: Introduction

    USB/IP PTZ Camera 12x Zoom, PoE 2. Introduction The MuxLab USB/IP PTZ Camera 12X Zoom, PoE (model: 500791-V2) is a full HD 1080p HDMI, USB and IP streaming camera with Pan, Tile, and Zoom capability for extreme flexibility and reach. The camera supports uncompressed video via an HDMI or USB outport for local connectivity, and H.264/H.265 compressed video for streaming over the Internet, while...
  • Page 5: Specifications

    1080P60 YUY2. Video Format USB Video Communication UVC 1.1 or UV C1.5 Protocol 32K sampling frequency, supported UAC2.0 Audio on USB Supported UVC PTZ Control © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 6 Operating Temperature 0°C ~ 40°C -10°C ~ 50°C Storage Temperature Power Consumption 169mm x 142mm x 175mm Size Net Weight 1.5Kg 2 years Warranty Order Information 500791-V2 USB/IP PTZ Camera 12x Zoom, PoE (UPC: 627699017913) © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 7: Product Connection

    (Note: If preset 0 is saved, PTZ will be move to preset 0) 7. Video Format Video Format 1080P60 1080P50 1080P59.94 1080I60 1080I59.94 1080I50 1080P29.97 720P60 720P50 1080P30 720P59.94 1080P25 Note: After switching the video format, you need to restart the camera before taking effect! © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 8: About Product

    POWER Indicator Microphone LINE IN Interface LINE OUT Interface Security Slot System Select Switch RS485 Interface RS232 IN Interface RS232 OUT Interface LAN Interface HDMI Interface 3G-SDI Interface USB 3.0 Interface 12VDC Power Interface Power Switch © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 9: Dimension

    USB/IP PTZ Camera 12x Zoom, PoE 8.2 Dimension © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 10: Installation Wall-Mount

    USB/IP PTZ Camera 12x Zoom, PoE 9. Installation Wall-Mount © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 11: Remote Control

    [*]+[#]+[1]: OSD menu default English [*]+[#]+[3]: OSD menu default Chinese [*]+[#]+[4]: Display current IP address [*]+[#]+[6]: Quickly recover the default [*]+[#]+[8]: View the camera version [*]+[#]+[9]: Quickly set up inversion [*]+[#]+[MANUAL]: Restore default IP address. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 12: Osd (On Screen Display) Gui Interface

    Press the [HOME] key to enter the corresponding sub- menu. 11.1 Exposure Move the cursor to the Exposure submenu in the main menu and press the [home] button, the EXPOSURE submenu will appear as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 13: Color

    DRC Mode: Manual, Auto, Off. DRC: 0~14. Matering Mode: Average, Bottom, Center, Top. 11.2 Color Move the main menu cursor to [Color], and press [HOME] key to enter the color page, as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 14 R-Gain: 0 ~ 255. B-Gain: 0 ~ 255. Color Temp: 2000K ~ 8500K Hue: 0 ~ 99. Saturation: 60 ~ 200%. Indoor R-Tuning: -128 ~ 127. B-Tuning: -128 ~ 127. Hue: 0 ~ 99. Saturation: 60 ~ 200%. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 15: Image

    NR-3D: 0 ~ 15 (Effective only in NR-3D Mode to Manual). PF Correction Mode: ON, OFF (Effective only in NR-3D Mode to Manual). PF Correction Level: 0 ~ 15 (Effective only in PF Correction Mode to ON). © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 16: Display

    Display Info: On, Off GDC: On, Off 11.5 P/T/Z Settings Move the cursor to the P/T/Z submenu in the main menu and press the [home] button. The P/T/Z submenu will appear as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 17: Communication Setup

    Digital Zoom: 2x, 4x, 8x, 16x, Off 11.6 Communication Setup Move the cursor to the Communication Setup submenu in the main menu and press the [home] button. The Communication Setup submenu will appear as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 18: Tracking

    Auto Frame, Zone, Presenter or Off. 11.8 Language Move the cursor to the Language option in the main menu and press the [ ] button to select one of the following language options: .English and Chinese © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 19: Default

    Press the Home button to set the factory default settings. 11.10 Version Move the cursor to the Version submenu in the main menu and press the [home] button. The Default submenu will appear as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 20: Web Settings

    NDI license verification (if applicable), and other information. 12. Web Settings Access http://192.168.100.88 to pop up the login window, then input username (default: admin) and password (default: admin). After login, it will show as below: © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 21: Control Camera

    4) PTZ Speeds: Pan speed can be set at any rate between 1 ~ 24, Tilt speed can be set at any rate between 1 ~ 20. Zoom and Focus speeds can be set at any rate between 1 ~ 7. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 22: Video Settings

    7) Tracking: By modifying tracking parameters, different close-up ratios can be obtained, and tracking can be set on/off, so as to display areas and character positions. If necessary, you can also choose whether to display tracking related prompt information. 12.2 Video Settings © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 23: Tracking

    If necessary, you can also choose whether to display tracking related prompt information. Step 1: Enter the “Tracking” option, select speaker mode “Presenter”, and set the tracking parameters in the “Track Off” state. Tracking Mode: Speaker (Presenter)/Area (Zone) The default is Presenter Mode. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 24 Step 3: Select the desired close-up effect. Figure Size By selecting different modes, users can customize the proportion of characters in the close- up screen, which is a very important feature. The modification here takes effect immediately. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 25 Upper: The close-up image includes tracking the target above the knee, as shown in the following figure. Close: The close-up image includes tracking the target above the waist, as shown in the following figure. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 26 Preset 1. If someone enters the video screen at this time, the camera will automatically track. When the tracking target is lost (exceeding the timeout), the camera will automatically move to Preset 1. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 27 Step 4: According to the requirements of the application scenario, you can choose whether to require “Humanoid frame” and “Tracking hint”, with default modes. Used in live streaming scenarios, it is often not opened for temporary adjustments during live streaming. Humanoid frame: Default/Off/Debug © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 28 On: There will be a prompt in the upper left corner of the video during switch tracking. Off: There is no prompt in the upper left corner of the video during switch tracking. This function is also applicable to live streaming scenarios. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 29 Step 1: Enter the “Tracking” page and select “Zone”. In the track off state, set the tracking parameters. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 30 When tracking is turned on, the camera will first move to this Zone position. If someone enters the video screen at this time, the camera will automatically track. When the tracking target is lost, the camera will automatically move to this Zone position. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 31 USB/IP PTZ Camera 12x Zoom, PoE © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 32: Image Settings

    Manual), Gamma Mode (Auto, Manual), Gamma (0.45, 0.50, 0.54, 0.56, 0.63, Exp, HLG), Flip-H (on, off), Flip-V (on, off) 5) Noise Reduction: NR-2D Mode (Auto, Manual), NR-2D (0~99), NR-3D Mode (Auto, Manual) 6) Style: Style (Default, Cold, Warm, Clear, Soft, HLG, Education, User 1/2/3 ). © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 33: Audio Settings

    1) Initialize: The user can perform a reboot or a factory default of the camera. 2) User: The user can modify the administrator and guest password (letters and Numbers only). 3) Online Upgrade: The user can update firmware version by selecting specific file. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 34: Network Settings

    7) Multicast Settings: Turn On/Off Multicast option, address 224.1.2.3, port 6688. 8) NTP Settings: Setting NTP Time Zone and Server Address. Turn On/Off Time Show, set the position of the Time Show. Turn On/Off Subtitle Display, set the Subtitle Content of the camera screen. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 35: Ndi Settings (Optional)

    8) Enable NDI® Multicast Server: Turn On/Off NDI Multicast Server 9) NDI® Multicast Address: Setting NDI Multicast Address. 10) NDI® Multicast Mask: Setting NDI Multicast Mask. 11) NDI® Multicast TTL: Setting NDI® Multicast TTL. 12) NDI® Firmware Version: Display NDI® Firmware Version. © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 36: Overlay

    12.9 Overlay 1) Time Enable: Show or hide time 2) Title Enable: Show or hide title. 3) Title: Enter title. 4) Horizontal Position: Setting horizontal position. 5) Vertical Position: Setting vertical position. 12.10 Device Information © MuxLab Inc. 2024 94-001064-A/SE-001064-A...
  • Page 37: Troubleshooting

    Check whether the control line is connected well. 2321 Cohen | St-Laurent , H4R 2N7 | Québec, Canada Tel: 514-905-0588 | Fax: USB/IP PTZ Camera 12x Zoom, PoE 514-905-0589 | Toll free: 1-877-689-5228 info@muxlab.com | 500791-V2 salesteam@muxlab.com | www.muxlab.com Follow us:...

This manual is also suitable for:

500791

Table of Contents