IBM 2077-4H4 Getting Started Manual
IBM 2077-4H4 Getting Started Manual

IBM 2077-4H4 Getting Started Manual

Control enclosures

Advertisement

Quick Links

IBM FlashSystem 5100
IBM Storwize V5100
Control Enclosures
Getting Started Guide
Overview
This document describes the installation procedures for the following IBM FlashSystem
information to help you plan the system configuration. This information applies to the following machine type and model (MTM) numbers.
Control Enclosure
IBM
FlashSystem 5100
®
Storwize V5100
Important: This document is intended to be used by persons who are experienced with installing these systems. Before you use this
information and the product it supports, read the following topics:
Installation worksheets
Safety and environmental notices
Notices
on page 11
IBM Systems Environmental Notices
IBM Knowledge Center (https://ibm.biz/BdqxdY) contains more information about preparing the physical environment before the
installation; it also provides information about configuring, managing, and servicing the system after installation. The IBM Knowledge
Center is updated between product releases to provide the most current documentation.
Unpacking and verifying the contents
Before you start the installation process, ensure that the following items are available.
Philips screw driver
Box knife
Flat-blade screw driver (optional)
Three Ethernet cables
The control enclosure and the following related parts are included in one box. The enclosed inventory sheet lists the part numbers of the
items that were ordered. Items, such as drives and networking adapters, are preinstalled inside each node canister.
Control enclosure with the following components preinstalled:
– Two node canisters with optional networking adapters, SFPs, and memory.
– Two power supply units (PSUs).
– A combination of 24 drives and drive blanks.
The number of drives and drive blanks varies, according to the number of drives that were specified in the product order. For
example, if 12 drives were ordered, the drives and 12 drive blanks are preinstalled in the control enclosure.
Rail kit, which includes the left and right rails, and 8 securing M5 screws and locating pins.
Cables, if they were ordered, for the type and number of networking adapters that are installed in each node canister.
Two power cables.
MTM
Comments
2077-4H4 / 2078-4H4
Control enclosure
2078-UHB
Utility control enclosure
2077-424 / 2078-424
Control enclosure with the ability to add hybrid expansions.
2077-AF4 / 2078-AF4
Control enclosure with support to add all-Flash expansions (IBM Storwize V5100F).
2078-U5B
Utility control enclosure
on page 8
on page 10
and
IBM Systems Safety Notices
and Storwize
®
(provided on a DVD with your product order)
IBM
systems. It also contains
®
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2077-4H4 and is the answer not in the manual?

Questions and answers

Summary of Contents for IBM 2077-4H4

  • Page 1 IBM Knowledge Center (https://ibm.biz/BdqxdY) contains more information about preparing the physical environment before the installation; it also provides information about configuring, managing, and servicing the system after installation. The IBM Knowledge Center is updated between product releases to provide the most current documentation.
  • Page 2 CAUTION: The weight of this part or unit is between 32 and 55 kg (70.5 and 121.2 lb). It takes three persons to safely lift this part or unit. (C010) Unpack the control enclosure To unpack the control enclosure, complete the following steps. If three persons or a lift are not available, more steps are required to remove some parts before the control enclosure can be installed.
  • Page 3: Removing And Replacing Parts

    6. Secure the rear of the rail to the rear rack flange with two black M5 screws (5). 7. Repeat Step on page 2 through Step on page 3 to secure the opposite rail to the rack cabinet. 8. Remove each end cap from the front of the enclosure. Lift the bottom of each end cap 9.
  • Page 4: Removing And Replacing A Drive

    8. Press the release levers closed to fully engage the node canister into the enclosure. Press the latch ends to ensure that the latches are engaged with the control enclosure. Removing and replacing a drive Use the following procedures to remove and replace a drive or an IBM FlashCore Module (FCM) from a node canister. About this task •...
  • Page 5: Connecting Sas Cables

    5U expansion enclosures. The system supports an intermix of 2U and 5U expansion enclosures with a total chain weight of 10 in each of two SAS chains. For more information about expansion enclosures, see IBM Knowledge Center (https://ibm.biz/BdqxdY). 1. Using the supplied SAS cables, connect the control enclosure to the first expansion enclosure.
  • Page 6: Powering On The System

    Connecting Ethernet cables 1. Connect Ethernet port 1 of each node canister to the IP network that will provide connection to the system management interfaces. Ethernet port 1 can be used for iSCSI connectivity to the system by hosts on the network. If the system has more than one control enclosure, ensure port 1 of every node canister is connected to the same network to provide access if the configuration node fails.
  • Page 7 Setting up the system or adding the control enclosure to an existing system The system can contain 1-4 control enclosures. If you are adding a control enclosure to an existing system, go to Adding a control enclosure to an existing system on page 7.
  • Page 8: Browser Considerations

    Browser considerations The management GUI supports the following HTML5-compliant browsers. Certain features must be enabled on the browser. Review the documentation that is provided with your browser to determine how to enable each item. Browser Required enabled features • Mozilla Firefox 80.0.1 •...
  • Page 9 Are you adding this control enclosure to an existing system? ❐ Yes ❐ No Control Enclosure S/N: Address Type IP Address Network Mask Default Gateway Secondary system address (optional) Node canister 1 service address (required) Node canister 2 service address (required) Network cable worksheet Use the following worksheets to record the location and type of cable connections for each control enclosure in the system.
  • Page 10: Safety And Environmental Notices

    2. Locate the IBM Systems Safety Notices document with the user publications that were provided with your system hardware. 3. Find the matching identification number in IBM Systems Safety Notices. Then, review the topics about the safety notices to ensure that you are in compliance.
  • Page 11: Environmental Notices

    IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used.
  • Page 12 Any references in this information to non-IBM websites are provided for convenience only and do not in any manner serve as an endorsement of those websites. The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk.
  • Page 13: Homologation Statement

    This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks. Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions.
  • Page 14 Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 800 225 5426 e-mail: Halloibm@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55032 Klasse A.
  • Page 15 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors, or by unauthorized changes or modifications to this equipment.
  • Page 16 This edition applies to version 8, release 4, modification 0, and to all subsequent modifications until otherwise indicated in new editions. Copyright International Business Machines Corporation 2018, 2020. © US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. (1P) P/N: 03GU854...

Table of Contents