Applied knowledge. Shared know-how. Fearless innovation. Together, we are Dutypoint. Since 1976, we’ve been building up industry-defining expertise in fluid technology. This knowledge means we solve complex challenges with straightforward solutions that are built around meeting and exceeding our clients’ needs. We approach everything with the same philosophy:...
Tank level control parameters Frequently asked questions Troubleshooting Control panel wiring diagrams VASCO pump controllers Optional extras & alternative configurations Declaration of Conformity Dutypoint standard warranty Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Normal safety precautions must be taken and appropriate procedures observed to avoid accidents Refer to Dutypoint for any technical advice or product information. It is the responsibility of the customer and/or the contractor: To ensure that anyone working on the equipment is wearing all necessary protective gear/clothing Is aware of appropriate health &...
Locking out the equipment by switching off the release mechanism or set value WILL NOT prevent accidental starting Allow the item(s) to cool if over-heated CLOSE the isolating valves on the suction and discharge connections of the affected item(s) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Hard hat Safety goggles with side shields Protective footwear Protective gloves Respirator Ear protection First aid kit Safety devices Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Do not remove vent plugs from a pressurised system - ensure pressurised components are relieved of pressure before disassembly Ensure guards are in place during operation Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 8
When connecting external control wires care must be taken not to short circuit adjacent components. Bare cable ends which are not in use must be insulated Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 9
Use of non-genuine spare parts may cause damage to equipment, damage to property and voiding of warranty Use genuine, Dutypoint-approved spare parts only If in doubt, contact Dutypoint Service on 01452 300590 Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 10
1) Inspect the package Inspect the package for damage or missing items upon delivery Note any damaged or missing items on the shipping paperwork and contact Dutypoint immediately File a claim with the shipping company if anything is out of order...
Page 11
If applicable, unfasten the product by removing any screw, bolts or straps. For your personal safety, be careful when you handle nails and straps. Contact Dutypoint if you have any issues. The unit comes delivered atop a pallet to be manoeuvred into position via forklift or pallet truck (also known as pallet jacks).
Page 12
Keep forklifts clean free from excess oil and grease Repair and maintain according to the manufacturer’s recommendations Some manual handling may be required when transporting and positioning the unit. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 13
Protect the product against humidity, heat sources and mechanical damage Do not place heavy weights on the packed product See section on storage limits Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 14
Do not place the product in a location susceptible to frost Do not leave the product full of water when not in use For more information on decommissioning and disposal contact the Dutypoint Service Team on 01452 300590. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com...
3/4" or 1" ultra-high flow failsafe motorised ball valve WX1 models: 1¼” BSP Discharge WX2 models: 1½” BSP Pressure vessel 12-24 L WRAS-approved expansion vessel Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 16
(V/Ph/Hz) @ full load (A) 3040-T230 0.55 3040-T230 0.75 3080-T230 3100-T230 5040-T230 0.75 230/1/50 230/3/50 5060-T230 5080-T230 5100-T230 9040-T230 9060-T230 9070-T 400/3/50 400/3/50 9090-T Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 17
PRESSURE TRANSDUCERS MOTORISED INLET VALVE NON - RETURN VALVES OVERFLOW (1½” OR 2” BSP) SUBMERSIBLE PUMPS INCOMING MAIN (¾” OR 1” BSP) LEVEL CONTROL SENSOR Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 18
Installation, use and maintenance manual ® 2. Specifications 2.2. PUMP CURVES (SINGLE PUMP) Figure 2.4: WXx-3000 Series Pump Curves SINGLE PUMP CURVES 3080 3060 3040 Flow Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 19
ScubaTANK Installation, use and maintenance manual ® 2. Specifications Figure 2.5: WXx-5000 Series Pump Curves SINGLE PUMP CURVES 5080 5060 5040 Flow Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 20
ScubaTANK Installation, use and maintenance manual ® 2. Specifications Figure 2.6: WXx-9000 Series Pump Curves SINGLE PUMP CURVES 9060 9040 Flow Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Test and commission - see Section 4. Commissioning (p. 30). NOTE The ScubaTANK must be installed on a stable, level surface or plinth capable of ® supporting the tank and liquid. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 22
The tank is free-standing and should be installed on a level and structurally sound surface Suitable measures must be taken to prevent the ingress of liquids into the tank, such as protection from drips Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
The system must only be operated when it has been correctly earthed and pipes bonded to earth in accordance with the latest IEE regulations Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 24
20 (1~) 40 (1~) 9060 WX1-9060-xxx WX2-9060-xxx 20 (1~) 40 (1~) 9070 WX1-9070-xxx WX2-9070-xxx 20 (3~) 40 (3~) 9090 WX1-9090-xxx WX2-9090-xxx 20 (3~) 40 (3~) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 25
Common fault volt-free contact WX2 (twin pump) single phase models: Common fault volt-free contact WX1 and WX2 three phase models: Common fault volt-free contact Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 26
WX1 (single pump) single phase models: Remote on/off contact WX2 (twin pump) single phase models: Remote on/off contact WX1 and WX2 three phase models: Remote on/off contact Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 27
Reconnect the inlet valve power connector Connect pump(s) to union and tighten Re-wire pump(s) to control panel NOTE Ensure you follow the procedure according the following images and instructions. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 28
DO NOT LEAVE A GAP next flange, ensure an overlap. BETWEEN SEALS. NOTE Some sealant may squeeze out from between the flanges, which is normal Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
For WX2 (twin pump) models, the green core from the level sensor connects to terminal 7 in the control box, and the brown core connects to terminal 8 (for full wiring schematics, see p. 55). Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
All commissioning works must be carried out by Dutypoint or an authorised company acting on behalf of Dutypoint. Please note that engineer visits by Dutypoint are priced at one visit to commission one pump set. If there are multiple units on a site, special terms can be negotiated. To arrange a commissioning visit, please call the Technical Service Help line on 01452 300590.
Page 31
If the maximum pressure generated by the pump in a system is 6 bar, this will require a pre-charge pressure of 6 × 90% = 5.4 bar. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
For full details of these unites, refer to Section 14. VASCO Pump Controllers (p. 59) If in doubt, please call Dutypoint Systems Technical Support on 01452 300590 for advice. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com...
Page 33
With all the isolators ON and the switches and/or control programs set to AUTO, the pump set is now fully operational in automatic control mode. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 34
Controller(s) and the Pump motor(s) should never be switched off. CAUTION The typical sound levels of the units in operation are less than 70 dBA. However, if sound levels exceed this limit, cease operations immediately and contact Dutypoint Service on 01452 300590. 4.11. CLEARANCE...
Inv: ON Mot: OFF - VASCO is powered but motor is not running (i.e. motor/pump was stopped due to minimum frequency being reached). Inv: OFF Mot: OFF - VASCO is not powered. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 36
You should only access and adjust parameters if you are trained to do so All full descriptions of the advanced parameters are available in the appendix of this manual For further assistance, call the Dutypoint Technical Service line on 01452 300590 Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 37
To exit the Menu level and return to the initial display, press STOP button. For full details on the VASCO controller, see Section 14. VASCO Pump Controllers on p. 59. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
6. Pressure vessel 6. PRESSURE VESSEL The pressure vessel supplied as part of your Dutypoint product is used to absorb and conserve the potential energy of the pressurised liquid. Stored energy from liquid under pressure is transferred to the water system when required.
When the pre-charge pressure is correct, replace the air valve cap and vent cover. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
(a temporary pressure peak, limited to 10% of the maximum tolerated pressure, is allowed). Make sure the cap of the valve is fitted tightly after pre-loading and that there is no leakage. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
7. System user maintenance 7. SYSTEM USER MAINTENANCE Dutypoint pump sets have been designed to keep major maintenance requirements to a minimum. Planned maintenance of the pumps and other principal components should therefore be undertaken at the intervals recommended in the manuals referenced below.
Locate the 4× plastic screw covers protecting the M6 screws securing the tank lid. Remove the covers and screws and lift off the tank lid to access the old pump. Disconnect the pump pipework. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
If the rotation is reversed, the values will be approximately double those indicated on the nameplate. Ensure the pump is vented before operating the system. Correct before using the system. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Section 6.3 Checking and Adjusting Pressure Vessel Pre-Charge (p. 39). Figure 9.17: VASCO Control Panel ENTER STOP MOTOR SCROLL UP/DOWN START MOTOR Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Changing these parameters from the default value could cause the system to malfunction and the tank to overflow. Parameters should only be changed by authorised persons. If in doubt, contact the Dutypoint technical department. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com...
See Section 6.3 Checking and Adjusting Pressure Vessel Pre-Charge (p. 39). 11.5. HOW DO I CHANGE THE PRESSURE SET POINT? See Section 9. Pressure Set Point Adjustment (p. 44). Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Troubleshooting VASCO-equipped booster sets. The information in this section is common to all VASCO-equipped Dutypoint booster sets. For more detailed troubleshooting information specific to the type and model of pump controller used, please refer to the manufacturer’s literature in the Appendix. ...
Page 48
6. Verify normal operation No water in break 1. Check incoming mains pressure is as expected tank 2. Check the water level in the tank Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 49
Check level settings are set up to the default values (see Level parameters have been adjusted overflowing p. 27) Pump runs Contact Dutypoint service on 01452 300590 continuously Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110...
Page 50
You should only access the Installer and Advanced menus if you are trained to do so A full description of these is available in the Appendix to this manual For further assistance, call the Dutypoint Technical Service line on 01452 300590 Figure 12.13: VASCO Controller Alarm Messages...
Page 51
Make sure the buttons are not depressed A button on the keyboard has been KEYBOARD FAULT If the problem persists, call Dutypoint Technical Service on pressed for more than 150 seconds 01452 300590 ACTIVE Check the input digital configuration (IN/OUT parameters Digital input X opened/closed DIG.IN.X...
Figure 13.2.0: Single pump system line diagram (WX1 models) [Single phase w/o optional extras] Figure 13.2.1: Single pump system line diagram (WX1 models) [Single phase w. Sabbath function (Variant A)] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 53
Figure 13.2.2: Single pump system line diagram (WX1 models) [Single phase w. temperature sensor and purge valve (Variant B)] Figure 13.2.3: Single pump system line diagram (WX1 models) [Single phase w. all optional extras (Variant C)] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 54
Figure 13.2.4: Single pump system line diagram for Twin Tank systems (WX1/1 & WX2/1 models) [Single phase w/o optional extras (Variant D)] Figure 13.2.5: Single pump system line diagram (WX1 models) [Three phase] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 55
Figure 13.2.6: Twin pump system line diagram (WX2 models) [Single phase w/o optional extras] Figure 13.2.7: Twin pump system line diagram (WX2 models) [Single phase w. Sabbath function (Variant A)] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 56
Figure 13.2.8: Twin pump system line diagram (WX2 models) [Single phase w. temperature sensor and purge valve (Variant B)] Figure 13.2.9: Twin pump system line diagram (WX2 models) [Single phase w. all optional extras (Variant C)] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 57
Figure 13.2.10: Twin pump system line diagram for Twin Tank systems (WX2/1 & WX2/2 models) [Single phase w/o optional extras (Variant D)] Figure 13.2.11: Twin pump system line diagram (WX2 models) [Three phase] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 58
ScubaTANK Installation, use and maintenance manual ® 13. Control panel wiring diagrams Figure 13.3: Twin Tank Link Cable Wiring Detail Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Failure to observe and follow the instructions in this manual may result in dangerous and potentially lethal electric shock. Pay attention to all standard safety and accident prevention regulations. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 60
Tampering or disassembly of any component will automatically void the warranty NOTE Vent pump(s) to remove any air pockets once submerged before testing the system. Dry running of the pump(s) will damage the system Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
101% of the nominal current for 10 min, 110% nominal current for 1 minute 14.3. TECHNICAL SPECIFICATIONS Figure 14.22: V209/V214 Electrical Wiring Board Figure 14.23: V409 Electrical Wiring Board Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 62
P.E. Eyelet for M4 screw Fork for M4 screw Fork for M4 screw Motor MOTOR Fork for M4 screw P.E. Eyelet for M4 screw Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 63
Open or Normally Closed Motor start/stop Active low Switching of sensors 1 & 2 Alarms reset Motor start/stop Active low Switch between main and auxiliary control modules Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 64
We recommend using overload protection with the characteristic curve of Type C and Type B circuit breaker, sensitive to both AC and DC current (100 mA sensitivity) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Make sure to remove the auxiliary cooling fan if VASCO is coupled to a motor. Failure to do so creates a high risk of overheating the motor and VASCO unit. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 66
1 auxiliary fan 230 V AC (VASCO 209,214) 2 screws to fix cooling fan 1 fan protection plate 2 wall mount brackets 4 screws to fix VASCO to wall bracket Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Inv: ON Mot: OFF - VASCO is powered but motor is not running (i.e. motor/pump was stopped due to minimum frequency being reached) Inv: OFF Mot: OFF - VASCO is not powered Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 68
Advanced parameters. Improper settings can compromise the integrity and life of the controller and pump You should only access and adjust parameters if you are trained to do so For further assistance, call the Dutypoint Technical Service line on 01452 300590 Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 69
Rated motor freq f = XXX Rated frequency of the motor as per its nameplate [Hz] Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
XXX.X [bar] Value compensation at the maximum Compensation frequency for each pump. Acting on the XXX.X [bar] green button you can reverse the sign Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 71
DOL 1 (Direct On Line pump) Pump DOL 2 Function to activate (ON) the second ON/OFF auxiliary pump DOL 2 (Direct On Line pump) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 72
“no water” alarm Restart delay after a dry running alarm. At Restarts delay each tentative (max 5) restart delay will be XX [min] doubled Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 73
ON/OFF WARNING: review the safety information from earlier in this chapter Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 74
VASCO runs the motor if the digital input 4 is closed; motor will be stopped if the digital input 1 is opened Digital input IN2 & IN3 delay Dig.In2/3 delay [s] Digital input IN1 has 1 second fix delay Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Reduce the PWM value (Advance Parameter Menu) Check if load is properly connected to the NO LOAD No load VASCO terminals Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 76
Check the input digital configuration (IN/OUT ACTIVE DIG.IN.X Digital input X opened/closed Parameters menu) ALARM SLAVE XX Slave XX error detected by master Check the status of the slave Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
(0.5 mm ) wired on the S+, S- and G pins on control board. MASTER: address 00 SLAVE 1: address 01 SLAVE 2: address 02 Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Start delay AUX t = XX [s] the maximum frequency and the pressure value has fallen below the set value – delta control Press STOP (red button). Press STOP again. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 79
Modify the value of Ki & Kp parameters (Control parameters menu). At first, it is suggested that the Ki value be reduced. If it is not enough, increase of one unit the Kp value Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
(bottom of the sensor to be suspended no higher than 50 mm from the bottom of the tank). CAUTION If this step is not correctly completed before powering the system on, the tank may overflow Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 81
Test and commission - see Section 4. Commissioning (p. 30). NOTE ScubaTANK units cannot be combined retrospectively; they can only be designed to ® be combined while being manufactured in the factory Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 82
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.01: SRP-73 Controller Datasheet Extract Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations 15.2. SABBATH MODE Figure 15.02: Timer Datasheet Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 84
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.02: Timer Datasheet (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 85
All model codes that feature a S include a timer that can be used for Sabbath Mode; WX2/1-1-5040-0575-HS1-AB20-M-GXIXGXIX-SHPLR-TADE Sabbath mode code in model number 15.3. LS - TM HIGH LEVEL FLOAT SWITCH Figure 15.03: Float Switch Datasheet Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 86
Figure 15.03: Float Switch Datasheet (continued) All model codes that feature a H include a LS-TM high/low level float switch; WX2/1-1-5040-0575-HS1-AB20-M-GXIXGXIX-SHPLR-TADE High level float switch code in model number Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 87
Connect the 2-core flying lead to terminals 19L and N in the control panel. Test and commission - see Section 4. Commissioning (p. 30). Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 88
Figure 15.05: High/Low Usage Selector Image All model codes that feature an L include an LS-TM high/low-level float switch; WX2/1-1-5040-0575-HS1-AB20-M-GXIXGXIX-SHPLR-TADE High/low usage selector code in model number Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Ensure the location selected is suitable for electrical equipment Ensure that the wall area is structurally sound and suitable to hold the weight of the equipment Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 90
If this step is not correctly completed before powering the system on, the tank may overflow Connect the inlet valve quick connector (supplied disconnected), ensuring the plug and socket are fully engaged and latched. Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
All model codes that feature an R are of a remote panel configuration; WX2/1-1-5040-0575-HS1-AB20-M-GXIXGXIX-SHPLR-TADE Remote control panel code in model number 15.7. TEMPERATURE SENSOR Figure 15.07: Temperature Sensor Datasheet Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 92
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.07: Temperature Sensor Datasheet (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 93
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.08: Temperature Controller Datasheet Extract Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 94
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.08: Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 95
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.08: Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 96
Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.08: Temperature Controller Datasheet Extract (continued) Figure 15.09: SRP-94 Temperature Controller Datasheet Extract Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 97
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 98
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 99
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 100
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 101
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 102
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 103
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 104
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 105
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 106
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 107
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 108
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 109
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 110
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 111
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Page 112
ScubaTANK Installation, use and maintenance manual ® 15. Optional extras & alternative configurations Figure 15.09: SRP-94 Temperature Controller Datasheet Extract (continued) Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
All model codes that feature a Dx include a manual drain valve. The second digit (options A-L) relates to the positioning of the valve on the tank itself. WX2/1-1-5040-0575-HS1-AB20-M-GXIXGXIX-SHPLR-TADE Drain valve and position code in the model number Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
® 16. Declaration of Conformity 16. DECLARATION OF CONFORMITY We: Dutypoint Limited. Of: Quedgeley West Business Park, Gloucester, Gloucestershire, United Kingdom in accordance with the following directives and Statutory Instruments where applicable: 2006/42/EC: Machinery Directive S.I. 2008:1597: The Supply of Machinery (Safety) Regulations 2008 2014/68/EU: Pressure Equipment Directive S.I.
17. DUTYPOINT STANDARD WARRANTY Your Dutypoint Systems standard product warranty is valid for a period of 24 months. To qualify for 24 months of cover, commissioning must take place in the first 12 months from the date of despatch, and a servicing visit must be completed within 12 months from the date of commissioning.
Page 116
ScubaTANK Installation, use and maintenance manual ® TALK TO THE TEAM 01452 300110 ENQUIRIES@DUTYPOINT.COM DUTYPOINT.COM Unit A, Quedgeley West Business Park, Gloucester GL2 4PA dutypoint.com + 44 (0) 1452 300110 enquiries@dutypoint.com...
Need help?
Do you have a question about the SCUBATANK WX Series and is the answer not in the manual?
Questions and answers