CONTENTS O P E R A T I O N 1 . 1 F I R S T F I R E 1 . 2 O N G O I N G U S E M A I N T E N A N C E 2 .
Page 3
CONGRATULATIONS Thank you for choosing an Artis fireplace for your living space. Your fireplace is the result of careful design and manufacture from Spain. If it is properly installed, used and maintained, you will be sure to have an outstanding feature for years to come.
OPERATION FIRST FIRE PREPARE THE UNIT Before lighting the first fire, ensure to remove all addiational components (ie. fireproof glove and paint can). Also ensure all plastic wrapping has been removed from all components (ie. grill, trays etc). FIRST FIRE Begin first fire in the slow combustion firebox section (see page 4 for reference), on the ash grate.
OPERATION ONGOING USE EXTINGUISHING THE FIRE Stop fuelling the fire, close all airflows completely, and let it burn out. The fire should burn out without any constraints. TRANSITION PERIOD, INSUFFICIENT CHIMNEY DRAUGHT AND POOR WEATHER CONDITIONS Pay attention to the operations of the fireplace during transition periods and/or when chimney draught is insufficient or when weather conditions are unfavourable, especially during severe cold weather.
MAINTENANCE CLEANING GLASS The vitro-ceramic glass can withstand temperatures of up to 700°C. If the glass breaks following a handling error, it is not recommended to replace it using a material other than that supplied by the manufacturer. The original glass quality must be used to maintain any warranty of the unit.
MAINTENANCE FIREBOX & CHIMNEY SAFETY FLUE & FIREBOX Flues should be professionally cleaned and checked twice a year, including at least once during the peak period of use, and more if required. A professional should also check seals, door ropes, glass positioning, door alignment, flue damper controls, baffle plates and all consumable parts of the firebox and flue to ensure the unit is in safe working order.
Page 8
MAINTENANCE FIREBOX & CHIMNEY SAFETY CHIMNEY FIRES (CONTINUED) Suggested course of action in case of chimney fires: 1. Put out the fire by carefully removing the glowing logs and fully close the fireplace door. 2.Use a chimney sieve screen (metal mesh 2 x 10mm, preferably brass, on a 60x60cm frame).
MAINTENANCE SERVICE CHECKLIST Check fireplace flue is not blocked and there is no visible creosote build up. Sweep as required Check flue / cowl has no damages and assess for wear Clean out ash from all areas of unit, ensure airways are all clear andthat air slides move in a normal capacity Check log holder and ash grates for wear and tear Inspect firebricks, replace if necessary...
MAINTENANCE TROUBLE SHOOTING ISSUE POSSIBLE CAUSE SUGGESTION Air supply ventilation is choked Provide a clear ventilation shaft Size of chimney shaft or its length is not Extend flue sufficient Mount chimney cap Smoke coming from Fault location of chimney relevant to roof ridge Apply reducer between...
Rust / Corrosion damage caused by environmental factors Faults due to improper / irregular maintenance Modifications made to any part of appliance which is not provided by manufacturer (Fm Calefaccion) or supplier (Artis Fireplaces Pty Ltd) Indirect damages (ie- handling accident) Resold units...
NOT to instruct independently. Whilst every effort is taken to avoid errors, Artis Fireplaces Pty Ltd and the manufacturer cannot accept responsibility for the accuracy of any statement, extract or information contained within this manual nor can any of its contributors who have submitted material for inclusion.