This is an anemometer, composed of a sensor of 3-cup assembly (AC generator type) and an indicator.
Specifications
1. Sensor (Generator)
Type of sensor
Starting wind speed
Withstand wind speed
Output voltage
2. Indicator
Type
Scale Range
Allowable error
Principle of measurement
1. Generator
Rotation of the 3-Cup assembly is transmitted to an AC generator. The AC voltage which is
proportional to wind speed is output.
2. Indicator
AC voltage from the generator is turned to DC voltage by a rectifier and the DC voltage operates
moving-coil type voltmeter.
Wiring
1. Generator
A short cord (approx. 1 m) is connected with the generator.
cord are used for the output of generator. Connect these to the indicator.
2. Indicator
Connect the wires with the terminals below the switch. There is no polarity since this is AC input.
Cautions at wiring between generator and indicator
If the wire resistance becomes large, it leads to error on indication of wind speed (about -1% at 200 ohm
per wire, 2.5km at 0.5mm², 3.5km at 0.75mm²).
transmission antennas and etc.
Instruction Manual for
No. 7760-00 3-Cup Anemometer
: 3-cup assembly - AC generator (four poles, non iron core)
: less than 2 m/s
: less than 90 m/s
: 30±1VAC at 60 m/s (output impedance: approx. 500 ohm)
: Rectifier type voltmeter (desk-top type)
: 0 to 60 m/s
Min. scale: 1 m/s (more than 2 m/s)
: Within ±0.5 m/s at less than 10 m/s
Within ±5% for the value at more than 10 m/s
Make sure to separate the cord from high-voltage circuit.
The black and white wires of the short
Use shield cord when it may be induced by
No.1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 7760-00 and is the answer not in the manual?

Questions and answers

Summary of Contents for SATO 7760-00

  • Page 1 No.1 Instruction Manual for No. 7760-00 3-Cup Anemometer This is an anemometer, composed of a sensor of 3-cup assembly (AC generator type) and an indicator. Specifications 1. Sensor (Generator) Type of sensor : 3-cup assembly - AC generator (four poles, non iron core)
  • Page 2: Maintenance

    No.2 Caution on installation 1. The wind speed sensor should be installed on a flat surface in an open space with a supportive pole, at a height of 10 m above the ground (standard installation place). “Open space” here means that the distance between the generator and any obstacle is at least 10 times (desirable: more than 20 times) the height of the obstacle.
  • Page 3 No.3 hole bottom lid short cord 2 cores hole bottom scale main unit Polycarbonate resin glass 10% 3-Cup assembly Polycarbonate resin holding nut Name Materials 3-Cup Anemometer...
  • Page 4 No.4 switch for wind speed input terminal zero adjunstment screw Wind Speed Indicator 8 10 -1 00...
  • Page 5 No.5 M O-0 01A F N o . Code Name G AC Generator for wind speed V Voltmeter for indication AC generator C Condenser D Rectifier G R Resistance Z Serge absorber S Switch for wind speed Use shield cord when it may be induced by transmission antennas and etc.
  • Page 6 No.6 How to Install 3-Cup Assembly 3-cup sensor is factory installed before shipment. Do not tighten the retaining nut further. To replace the 3-cup assembly, follow the procedures mentioned below. 1. Confirm that the collar is installed in the rotary axis. 2.