CSAHP: Installation Instructions
CSAHP
Horizontal Duct Coils for Puron Advance™ Refrigerant
Heating and Cooling
IMPORTANT: This unit is to be used with Puron Advance (R-454B) refrigerant only. This system includes an internal sensor to detect any refrigerant
leaks with an external control board that must be connected to a furnace. This is only compatible with outdoor condensers that are Puron Advance
certified.
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECT EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Check Existing Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Insulate and Vapor-proof Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Install Coil in Supply Air Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Refrigerant Line Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 1 - Coil Connection Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . 3
TXV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Leak Dissipation System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
24V Control System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2 - Dissipation System Wiring Label . . . . . . . . . . . . . . . . . 6
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 3 - Communication Plug Designations . . . . . . . . . . . . . . . . 7
Leak Dissipation System Installation. . . . . . . . . . . . . . . . . . . . . . . 7
Table 4 - Dissipation Board Test Button Functions . . . . . . . . . . . 8
Table 5 - Required Operational Checks to Ensure Proper Dissipation
System Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 6 - Required Minimum Dissipation Mode Airflows,
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Sequence of Events - Dissipation Mode . . . . . . . . . . . . . . . . . . . 8
Flash Codes / Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 7 - Flash Code Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
UNIT START-UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Air Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Condensate Pan and Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cleaning Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or
use can cause explosion, fire, electrical shock or other conditions which
may cause death, personal injury or property damage. Consult a
qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses, protective clothing and
work gloves. Use quenching cloths for brazing operations. Have fire
extinguisher available. Read these instructions thoroughly and follow all
warnings or cautions attached to the unit. Consult local building codes
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Installation Instructions
and the current editions of the National Electrical Codes (NEC) NFPA
70.
In Canada, refer to the current editions of the Canadian Electrical Code
CSA C22.1.
Recognize safety information. This is the safety-alert symbol
you see this symbol on the unit and in instructions or manuals, be alert to
the potential for personal injury.
Understand the signal words DANGER, WARNING and CAUTION.
These words are used with the safety-alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury or
death. WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices, which
may result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
1
WARNING
!
PROPERTY DAMAGE HAZARD - FURNACE/COIL
MATCHING
Failure to follow this warning could result in property damage, personal
injury, or death.
This coil must be matched to heating equipment that meets all
CSA/ANSI Z21.47 or cooling equipment that meets UL 60335-2-40.
Refer to the furnace/blower installation instructions for any potential
considerations when installing coils with composite drain pans.
CAUTION
!
PARTIAL UNIT REQUIREMENTS
Failure to follow this warning could result in equipment damage.
This family of evaporator coils are PARTIAL UNIT HEAT PUMP OR
AIR CONDITIONER, complying with PARTIAL UNIT requirements
of UL/CSA 60335-2-40 Standard, and must only be connected to other
units that have been confirmed as complying to corresponding
PARTIAL UNIT requirements of this UL/CSA 60335-2-40 Standard.
. When

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSAHP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier CSAHP

  • Page 1: Table Of Contents

    CSAHP: Installation Instructions CSAHP Horizontal Duct Coils for Puron Advance™ Refrigerant Heating and Cooling Installation Instructions IMPORTANT: This unit is to be used with Puron Advance (R-454B) refrigerant only. This system includes an internal sensor to detect any refrigerant leaks with an external control board that must be connected to a furnace. This is only compatible with outdoor condensers that are Puron Advance certified.
  • Page 2: Introduction

    INTRODUCTION HOT TUBE WARNING Failure to follow this caution could result in personal injury and/or Use these instructions to install Model CSAHP duct coils in the horizontal position. (Fig. 1) It is easily adaptable to most types of property damage.
  • Page 3: Insulate And Vapor-Proof Duct

    CSAHP: Installation Instructions Insulate and Vapor-proof Duct CAUTION Externally insulated ductwork must have an adequate vapor seal for summer operation. This is particularly important where the duct is UNIT OR PROPERTY DAMAGE HAZARD exposed to high humidity conditions in attics, vented crawl spaces, Failure to follow this caution may result in property damage.
  • Page 4: Txv

    CSAHP: Installation Instructions 6. Use 1/2 psig Nitrogen purge in the suction and out the liquid line. 7. Braze using a Sil-Fos or Phos-copper alloy. Do not use soft solder. Metal Clamp ONLY 8. After brazing, allow joints to cool. Carefully remove TXV bulb...
  • Page 5: Electrical Connections

    CSAHP: Installation Instructions UNIT 2” MIN PRIMARY DRAIN (51 mm) 2” MIN (51 mm) A03002A Fig. 4 – Recommended Condensate Trap DO NOT USE SHALLOW RUNNING TRAPS! A03013 Fig. 5 – Insufficient Condensate Trap Condensate drain lines should be pitched downward at a minimum slope of 1"...
  • Page 6: Control System

    CSAHP: Installation Instructions Dissipation Board Housing The dissipation board housing (Fig. 9) (which contains the dissipation control board) is required to be installed on a wall or unit as close as possible to the furnace control box, within 8 feet (along the wire harnesses) of the refrigerant sensor and the furnace control board.
  • Page 7: Leak Dissipation System Installation

    G_out Terminal* SEC-1 : Dissipation terminal is only used on Carrier communicating furnaces manufactured Q4 2023 and later. Use a 3/16” spade connector on the GRN/VIO wire to connect to the dissipation terminal on communicating furnaces. Attach wire nut to all unused wires from the power harness.
  • Page 8: Based On Total System Refrigerant Charge Quantity

    CSAHP: Installation Instructions TROUBLESHOOTING 5. Power on unit and verify proper functioning of equipment. Yellow LED on control board should be steady. If flash codes are present, Sequence of Events — Dissipation Mode see the troubleshooting section. 1. Refrigerant leaks.
  • Page 9: Care And Maintenance

    However, a field-supplied filter must be used upstream of the coil and must be inspected frequently. When filter becomes clogged with dust or lint, it should be replaced (disposable type) or cleaned (cleanable type). © 2024 Carrier. All rights reserved. Edition Date: 2/24 Catalog No: IM-CSAHP-01...

Table of Contents