Istruzioni originali Pagina 85 Luchtontvochtiger Oorspronkelijke gebruiksaanwijzing Blz. 95 Osuszacz powietrza Instrukcja oryginalna Stronie 105 Dezumidificator de aer Instrucţiuni originale S. 115 Odvlhčovač vzduchu Originálný návod na použitie Strana 125 Razvlaževalnik zraka Navodilo za uporabo Stran 135 ALE 500 N...
Here with declare under our sole responsibility that the product transported to a disposal and collection point. This ensures that Luftentfeuchter (Air dehumidifier) type / model ALE 500 N the refrigerant does not escape uncontrolled. Serial number: 000001 – 020000...
Residual risks can be minimised if the “Safety advices” and the “Intended usage” as well as the whole of the operating instructions are observed. Read and follow the operating instructions Observing these instructions, and taking proper care, will and safety advices before starting up the reduce the risk of personal injury or damage to the machine.
Only qualified persons are allowed to carry out repair work Room air is sucked through a filter and a refrigerating element on electrical equipment. The user of the device may be where water vapour in the air condense as water droplets. severly injured due to improper repair work.
4. Insert the connecting pieces (4) in the legs (2/3). Insert the legs in the transport handle and secure them to the enclosure using the 6 hexagon screws M6x40 and the washers After assembly, allow the device to stand vertically for at least one hour before powering it up.
6 Defrosting icon 7 “Fan ON” icon 8 “Water container full” icon Before starting up 9 “Dehumidification mode” icon Did you transport the air dehumidifier in horizontal position or at Continuous display = dehumidfication is running an angle large than 45°? (compressor and fan on) ...
Automatic defroster Continuous or extended operation At a room temperature under 20 °C not only condensation In the case of a high humidity of air it is recommended to water is generated on the cold evaporator surface, but also ice. operate the air dehumidifier in continuous mode.
Inserting the filter 1. After cleaning, reinsert the filter in the guides on the Power off the device and disconnect the mains enclosure door. plug before each transport. 2. Close the enclosure door. Always transport the air dehumidifier in upright (vertical) position to prevent compressor damages.
Power off the device and disconnect the mains plug before each troubleshooting. Fault Possible cause Corrective action Motor does not start No power supply. Check fuses. Mains cable defective. Have it checked (electrician). Water collecting container full. Drain the water collecting container. Humidity of the room air lower than the Check the set humidity value and set another value set value.
Type/ Model ALE 500 N Year of construction see last page Air flow rate 350 m³/h Rated power 700 W Rated current consumption 3.2 A max. power 820 W max. current consumption 3.7 A Power, fan 10 W Electrical power supply...
Need help?
Do you have a question about the ALE 500 N and is the answer not in the manual?
Questions and answers