IMPORTANT SAFETY INSTRUCTIONS
Read all safety warnings, instructions, illustrations and
WARNING
specifications provided with this product. Failure to
follow all instructions listed below may result in electric shock, fire
and/or serious injury. Save these instructions.
• Before use, test on a known live circuit to ensure the tool is functioning
properly. Do not use if damaged in any way.
• If no indication, voltage may still be present.
• Failure to follow instructions could result in serious injury or death.
• Use caution with voltages above 30V AC as a shock hazard may exist.
Do not apply more than the rated voltage as marked on the detector.
• Never assume neutral or ground wires are de-energized. Neutral wires
in multi-wire branch circuits may be energized when disconnected and
must be retested before handling.
• Operation may be affected by differences in outlet design and
insulation thickness and type.
• The detector WILL NOT detect voltage if:
• The wire is shielded.
• The voltage is DC.
• The detector MAY NOT detect voltage if:
• The wire is partially buried or in a grounded metal conduit.
• The field created by the voltage source is being blocked, dampened, or
otherwise interfered with.
• The frequency of the voltage is not a perfect sine wave between 50 Hz
and 500 Hz.
• The tip of the detector is not within 0.25" of an AC voltage source
radiating unimpeded.
• The air humidity is not nominal (50% relative humidity – non-condensing).
• The detector is not held still.
• Do not use the detector around strong electromagnetic fields.
• This tool is intended for indoor use.
• Do not stare at or look directly into laser.
• Thermometer is NOT intended for use on people or animals.
• Temperature readings of reflective materials may be cooler than the
actual temperature.
• Never use without battery cover in place.
• This tool is rated measurement category IV, for measurements
performed at the source of a low-voltage installation and outside line.
FUNCTIONAL DESCRIPTION
5
4
3
1
2
1. Tip
6. Battery cap
7. Numeric display
2. LCD screen
8. Units
3. Infrared thermometer
button (IR)
9. Low battery
4. Non-contact voltage
indicator
button (NCV)
10. Laser warning
icon
5. Clip
SYMBOLOGY
AC Current
CLASS 1 LASER PRODUCT
IEC 60825-1:2014-05
Max Laser Output < 0.39 mW
Wavelength = 630-670nm
Volts
W
Watts
Hz
Hertz
Measurement
CAT IV
Category IV
Safety Alert
CAUTION
Risk of
Electric Shock
4007177
SPECIFICATIONS
Cat. No. ........................................................................................2225-20
Safety Rating ................................................................ CAT IV 1000V AC
Voltage Measurement Range ...........................................12 to 1000V AC
Temperature Measurement Range ...................................... -22° to 482°F
Distance-to-Spot Ratio .........................................................................4:1
Frequency Range ................................................................. 50 to 500 Hz
Temperature Resolution ............................................................. 0.1 °F/°C
Temperature Accuracy
-22° to 68°F ...........................................................Accurate to +/- 5.4°F
69° to 482°F ..........................................Accurate to +/- 2% or +/- 3.6°F
Battery ..................................................... 2 x 1.5V AAA Alkaline Batteries
Operating Altitude ............................................................................. 6562'
Relative Humidity
Operating ..................................................... 10 to 90% non-condensing
Storage ............................................................... <80% non-condensing
Drop Protection.................................................................................... 6.6'
Dust/Water Ingress Protection ........................................................... IP54
Product Certification
Conforms to UL STD. 61010-1, 61010-2-030
Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030
Storage Temperature ......................................14° to 122°F (-10° to 50°C)
Recommended Ambient
Operating Temperature ...................................32° to 122°F (0° to 50°C)
ASSEMBLY
Changing Battery
Only use alkaline batteries. Do not use zinc-carbon batteries. If the tool will
not be used for a long time, remove the batteries as a protection against
corrosion.
1. When the batteries are low, the low battery indicator is displayed on
the LCD.
2. Twist 1/4 turn to unlock the battery cap.
3. Remove and properly dispose of the old batteries.
4. Install the batteries according to the polarity marked on the tool.
5. Twist 1/4 turn to lock the battery cap and ensure a tight seal with the
o-ring. WARNING! Never use tool without battery cover in place.
OPERATION
To reduce the risk of electric shock or injury, test on a
WARNING
known live circuit to ensure the tool is functioning
properly before use. Do not use detector if damaged in any way.
Turning the Detector On/Off
1. Press the NCV button to turn on the detector. The tip will light green
with a single beep.
2. Press the NCV button to turn off the detector.
3. The detector automatically shuts off after 5 minutes of no use.
Selecting Audible or Silent Mode
The detector automatically starts in audible mode when powered on. To
change the mode, press and hold the NCV button for two seconds. The
tip will flash green to indicate silent mode is activated, or it will flash green
and beep to indicate audible mode is activated.
Selecting Temperature Units
The detector automatically starts in Fahrenheit (°F) or the last selected unit,
when powered on. To change the units to Celsius (°C) or back to Fahrenheit,
press and hold the infrared thermometer and NCV buttons simultaneously.
NON-CONTACT VOLTAGE DETECTOR W/ LASER INFRARED THERMOMETER
TESTEUR DE TENSION SANS CONTACT AVEC THERMOMÈTRE À LASER INFRAROUGE
DETECTOR DE VOLTAJE SIN CONTACTO CON TERMÓMETRO DE LÁSER INFRARROJO
Checking for the Presence of AC Voltage
WARNING
Use caution with voltages above 30V AC as a shock hazard may exist.
Do not apply more than the rated voltage as marked on the detector.
• The detector WILL NOT detect voltage if:
• The wire is shielded.
• The voltage is DC.
• The detector MAY NOT detect voltage if:
• The wire is partially buried or in a grounded metal conduit.
• The field created by the voltage source is being blocked, dampened, or
otherwise interfered with.
• The frequency of the voltage is not a perfect sine wave between 50
and 500Hz.
• The tip of the detector is not within 0.25" of an AC voltage source
radiating unimpeded.
• The air humidity is not nominal (50% relative humidity – non-condensing).
• The detector is not held still.
1. Turn the detector on.
2. Place tip of the detector near AC voltage. If voltage is detected the tip
will turn red and beep:
• For low voltage (12V) detection, the red light blinks slowly and the tool
beeps.
• For high voltage (120V) detection, the red light remains on and the tool
beeps continuously.
WARNING
Do not stare at or look directly into the laser.
While holding down the IR button, aim the laser at the object to be mea-
sured. The temperature will display on the LCD. The error code "HI" will
appear on the LCD if the measurement is hotter than the measurement
range, or "LO" if it is colder. The error code "Ot" will appear if the am-
bient temperature is outside the operating temperature range.
NOTE: Releasing the button will hold the last measurement taken. The
thermometer will automatically deactivate after about 10 seconds of inac-
tivity and the held reading will be cleared.
The targeting laser has a distance-to-spot ratio of 4:1, which describes
the relationship of the distance between the detector and the object, to
the target measurement area.
6
4:1 Distance-to-Spot Ratio
9
7
8
10
Class 1
Laser
Keep tool clean, dry and free of oil or grease. Use only mild soap and a
Warning
damp cloth to clean.
Non-Contact
Voltage Button (NCV)
1-800-SAWDUST
Infrared
Thermometer
Button (IR)
Contact Corporate After Sales Service Technical Support with technical,
Read Operator's
service/repair, or warranty questions.
Manual
Email: metproductsupport@milwaukeetool.com
Become a Heavy Duty Club Member at www.milwaukeetool.com to receive
Intertek
important notifications regarding your tool purchases.
US
Certification
This MILWAUKEE power tool* is warranted to the original purchaser from an authorized MILWAUKEE
distributor only to be free from defects in material and workmanship. Subject to certain exceptions,
MILWAUKEE will repair or replace any part on this power tool which, after examination, is determined
by MILWAUKEE to be defective in material or workmanship for a period of two (2) years after the
date of purchase unless otherwise noted. Return of the power tool to a MILWAUKEE factory Service
Center location or MILWAUKEE Authorized Service Station, freight prepaid and insured, is required.
A copy of the proof of purchase should be included with the return product. This warranty does not
apply to damage that MILWAUKEE determines to be from repairs made or attempted by anyone
other than MILWAUKEE authorized personnel, misuse, alterations, abuse, normal wear and tear,
lack of maintenance, or accidents.
Normal Wear: Many power tools need periodic parts replacement and service to achieve best
performance. This warranty does not cover repair when normal use has exhausted the life of a
part including, but not limited to, chucks, brushes, cords, saw shoes, blade clamps, o-rings, seals,
bumpers, driver blades, pistons, strikers, lifters, and bumper cover washers.
*This warranty does not cover battery packs or all power tools. Refer to the separate and distinct
warranties available for those products.
The warranty period for the LED in the LED Work Light (49-24-0171) and the LED Upgrade Bulb
(49-81-0090) is the lifetime of the product subject to the limitations above. If during normal use the
LED or LED Upgrade Bulb fails, the part will be replaced free of charge.
Warranty Registration is not necessary to obtain the applicable warranty on a MILWAUKEE power
tool product. The manufacturing date of the product will be used to determine the warranty period
if no proof of purchase is provided at the time warranty service is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED
HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE
PRODUCT. IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE
THE PRODUCT. IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPE-
CIAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES,
EXPENSES, LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE
TO, FAILURE OF, OR DEFECT IN ANY PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY
CLAIMS FOR LOSS OF PROFITS. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION
OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF
ALL OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT PERMITTED BY
LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE
OR PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW, SUCH
IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS
WARRANTY AS DESCRIBED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU,
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER
RIGHTS WHICH VARY FROM STATE TO STATE.
This warranty applies to product sold in the U.S.A. and Canada only.
Please consult the 'Service Center Search' in the Parts & Service section of MILWAUKEE's website
www.milwaukeetool.com or call 1.800.SAWDUST (1.800.729.3878) to locate your nearest service
facility for warranty and non-warranty service on a MILWAUKEE power tool.
DIRECTIVES DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT
des bulletins fournis avec le produit. Ne pas suivre toutes les instruc-
tions énumérées ci-dessous, pourrait causer un choc électrique, un
incendie, des blessures graves et / ou décès. Sauvegardez ces in-
structions.
• avant d'utiliser ce produit, veuillez le tester sur un circuit sous tension
connu pour s'assurer que l'outil fonctionne comme il faut. Ne pas
utiliser s'il est endommagé de quelque façon que ce soit.
• Si aucun signale ne s'affiche, il est possible qu'il y ait toujours de
tension présente.
• Le non-respect des instructions pourra causer des blessures graves
ou la mort.
• Agir prudemment alors que vous travaillez dans des tensions
supérieures à 30 V CA, car un risque de décharge électrique pourra
survenir. Ne pas appliquer une tension supérieure à celle marquée
sur le testeur.
Failure to follow instructions could result in serious
injury or death.
Measuring Temperature
Thermometer is NOT intended for use on people or
animals.
Center of spot
Laser pointer
Spot size at distance
indicated
At 4" away,
spot is 1" in
At 8" away,
diameter
spot is 2" in
At 12" away,
diameter
spot is 3" in
diameter
Cleaning
SERVICE - UNITED STATES
(1.800.729.3878)
Monday-Friday, 7:00 AM - 6:30 PM CST
www.milwaukeetool.com
or visit
SERVICE - CANADA
Milwaukee Tool (Canada) Ltd
1.877.948.2360
Monday-Friday, 7:00 AM - 4:30 PM CST
or visit www.milwaukeetool.ca
LIMITED WARRANTY
USA & CANADA
Lire tous les avertissements de sécurité et
instructions en vous référant aux illustrations
• Ne jamais supposer que les fils neutres ou mis à la terre n'ont pas
de tension. Les fils neutres dans les circuits de dérivation à plusieurs
fils pourront être énergisés lors de la déconnexion et il faut les tester à
nouveau avant de les manipuler.
• L'opération pourra être touchée par les différences entre la disposition
de la prise et l'épaisseur et le type de l'isolement.
• Le testeur NE DÉTECTERA PAS de tension si :
• Le fil est blindé.
• La tension est d'une nature CD.
• Le testeur NE POURRA PAS DÉTECTER de tension si :
• Le fil est partiellement enterré ou s'il est dans un conduit métallique
mis à la terre.
• Le champ produit par la source de tension est bloqué, atténué ou
autrement empêché de quelque façon que ce soit.
• La fréquence de la tension n'est pas d'une onde sinusoïdale pure d'entre
50 Hz et 500 Hz.
• La pointe du testeur ne se trouve pas à une distance de 6 mm (0,25")
d'une source de tension CA à radiation continue.
• L'humidité de l'air n'est pas nominale (50 % d'humidité relative, sans
condensation).
• Le testeur n'est pas tenu immobile.
• Ne pas utiliser le testeur autour des champs électromagnétiques forts.
• Cet outil a été conçu pour une utilisation à l'intérieur.
• Ne pas voir ou regarder directement vers le laser.
• Le thermomètre N'A PAS été conçu pour une utilisation humaine
ou animale.
• Les lectures de température des matériaux réfléchissants pourront
être plus froides que la température réelle.
• Ne jamais utiliser si le couvercle des piles n'est pas installé.
• Cet outil est classé catégorie de mesure IV, pour les mesures effectuées
à la source d'une installation basse tension et d'une ligne extérieure.
DESCRIPTION FONCTIONNELLE
5
4
3
1
2
6. Couvercle des
1. Pointe
piles
2. Écran ACL
7. Écran numérique
3. Touche de
thermomètre
8. Unités
infrarouge (IR)
9. Avertisseur de
faible charge
4. Touche de tension
sans contact (TSC)
10. Icône
d'avertissement
5. Crochet
du laser
PICTOGRAPHIE
Courant alternatif
CLASS 1 LASER PRODUCT
V
IEC 60825-1:2014-05
Max Laser Output < 0.39 mW
Wavelength = 630-670nm
Volts
W
Watts
Hz
Hertz
CAT IV
Catégorie de mesure IV
Alerte de sécurité
ATTENTION
Risque de
décharge électrique
4007177
SPECIFICATIONS
No de Cat. ....................................................................................2225-20
Cote de sécurité ........................................................... CAT IV 1000V AC
Plage de mesure de tension .............................................12 à 1000V AC
Plage de mesure de température ................ -30° à 250°C (-22° à 482°F)
Rapport distance-point d'intérêt............................................................4:1
Plage de fréquence .............................................................. 50 à 500 Hz
Résolution de température ........................................................ 0,1 °C/°F
Précision de température D'entre
-30° à 20°C (-22° à 68°F) ...........à une précision de +/- 3°C (+/- 5,4°F)
21° à 250°C (69° à 482°F) .......... à une précision de +/- 2% ou +/- 2°C
Piles .........................................2 piles alcalines AAA de 1,5 V, 24 A LR03
Altitude d'exploitation........................................................2 000 m (6562')
Humidité relative
Exploitation ...............................................10 à 90% sans condensation
Rangement .....................................................<80% sans condensation
Protection contre chutes .............................................................2 m (6,6')
Indice de protection contre l'eau / la poussière ................................. IP54
Certification du produit
Conforme à UL STD. 61010-1, 61010-2-030
Certifié d'après CSA STD. C22.2 No. 61010-1, 61010-2-030
Température de rangement ..............................-10° à 50°C (14° à 122°F)
Température ambiante de fonctionnement
recommandée...................................................0°
MONTAGE DE L'OUTIL
Remplacement des piles
Utiliser uniquement des piles alcalines. Ne pas utiliser des piles au
zinc-charbon. Si l'outil n'est pas utilisé pour une longue période, retirer les
piles en tant que mesure de protection contre la corrosion.
1. Lorsque la charge des piles est faible, l'avertisseur de faible charge
s'affichera sur l'écran ACL.
2. Faire un 1/4 de tour pour déverrouiller le couvercle des piles.
3. Retirer les vieilles piles et les jeter comme il faut.
4. Installer les piles d'après la polarité marquée sur l'outil.
5. Faire 1/4 de tour pour verrouiller le couvercle des piles et s'assurer de le
fermer à étanchéité à l'aide de l'anneau torique. AVERTISSEMENT ! Ne
jamais utiliser sans le couvercle des piles sur place.
MANIEMENT
Afin d'éviter le risque de décharge électrique,
AVERTISSEMENT
veuillez le tester sur un circuit sous tension
connu pour s'assurer que l'outil fonctionne comme il faut. Ne pas
utiliser s'il est endommagé de quelque façon que ce soit.
Mise en marche / arrêt du testeur
1. Appuyer sur la touche TSN pour allumer le testeur. La pointe s'allumera
verte et bippera une fois.
2. Enfoncer la touche TSN pour éteindre le testeur.
3. Le testeur s'éteindra automatiquement après 5 minutes d'inactivité.
Sélection du mode sonore ou silencieux
Le testeur démarre automatiquement en mode sonore alors qu'il est allumé.
Pour changer le mode, enfoncer la touche TSN durant deux secondes.
La pointe clignotera vert pour signaler l'activation du mode silencieux, ou
bien il clignotera vert et bippera pour signaler l'activation du mode sonore.
Sélection des unités de température
Le testeur démarrera automatiquement, alors qu'il est allumé, en Fahren-
heit (ºF) ou la dernière unité sélectionnée. Pour changer les unités vers
Celsius (ºC) ou revenir sur Fahrenheit, enfoncer la touche TSN et celle du
thermomètre infrarouge en même temps.
6
9
7
8
10
Avertissement
concernant le laser
classe 1
Touche de tension .
sans contact (TSC)
Touche de
thermomètre
infrarouge (IR)
Lire le manuel du
propriétaire
Certification
US
Intertek
(+/- 3,6°F)
à 50°C (32° à
122°F)

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2225-20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milwaukee 2225-20

  • Page 1 MILWAUKEE will repair or replace any part on this power tool which, after examination, is determined Altitude d’exploitation............2 000 m (6562') by MILWAUKEE to be defective in material or workmanship for a period of two (2) years after the Temperature Accuracy Humidité...
  • Page 2 Esta herramienta eléctrica de MILWAUKEE* está garantizada, ante el comprador original única- ESPECIFICACIONES mente, por parte de un distribuidor autorizado MILWAUKEE, de que no tenga material y mano de obra defectuosos. Sujeto a ciertas excepciones, MILWAUKEE reparará o sustituirá cualquier pieza À...