SIGLENT TECHNOLOGIES SPS6000X Series User Manual

Wide range programmable switching dc power supply
Hide thumbs Also See for SPS6000X Series:
Table of Contents

Advertisement

Quick Links

SPS6000X Series User Manual
SPS6000X Series
Wide Range Programmable
Switching DC Power Supply
User Manual
EN01B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPS6000X Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGLENT TECHNOLOGIES SPS6000X Series

  • Page 1 SPS6000X Series User Manual SPS6000X Series Wide Range Programmable Switching DC Power Supply User Manual EN01B...
  • Page 3: Table Of Contents

    Conditions anormales ........................13 3 Delivery of The Power Supply ....................14 About Warranty ........................14 Maintenance Agreement ..................... 15 4 Introduction of SPS6000X Series ..................16 Performance and Features ....................17 Size ............................. 18 5 SPS6000X Series Overview ....................19 Rack mounting ........................
  • Page 4 SPS6000X Series User Manual Rear Panel .......................... 22 6 Theory of Operation ........................ 24 Operating Area Description ....................24 CC and CV Mode ........................ 24 Slew Rate ..........................25 Bleed Circuit ........................26 Alarms ..........................26 Considerations ........................27 6.6.1 Inrush current ......................
  • Page 5 SPS6000X Series User Manual 9.2.4 Set Output On/Off Delay Time ..................41 9.2.5 Set Measurement Accuracy ..................42 9.2.6 External Analog Control ....................43 9.2.7 External Control Output On/Off................... 44 9.2.8 Save/Recall ......................... 44 9.2.9 Analog Interface ......................46 Communication interface settings ..................48 Recalibration setting ......................
  • Page 7: Introduction

    SPS6000X Series User Manual Introduction This user manual includes important safety and installation information related to the SPS6000X series wide-range programmable switching DC power supply and includes simple tutorials for the basic operation of the supply. int.siglent.com...
  • Page 8: Important Safety Information

    SPS6000X Series User Manual Important Safety Information This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition. In addition to the safety precautions indicated in this section, you must follow accepted safety procedures.
  • Page 9: Safety Terms And Symbols

    SPS6000X Series User Manual 2.2 Safety Terms and Symbols When the following symbols or terms appear on the front or rear panel of the instrument or in this manual, they indicate special care in terms of safety. This symbol is used where caution is required. Refer to the accompanying information or documents to protect against personal injury or damage to the instrument.
  • Page 10: Working Environment

    SPS6000X Series User Manual 2.3 Working Environment Environment This instrument is intended for indoor use and should be operated in a clean, dry environment. Ambient temperature Operating: 0 ℃ to +50 ℃ Non-operation: -20 ℃ to +60 ℃ Note: Direct sunlight, radiators, and other nearby heat sources should be taken into account when assessing the ambient temperature.
  • Page 11: Cooling Requirements

    SPS6000X Series User Manual 2.4 Cooling requirements This instrument relies on forced air cooling with internal fans and ventilation openings. Care must be taken to avoid restricting the airflow around the apertures (fan holes) at the back of the power supply.
  • Page 12: Output Port Connections

    SPS6000X Series User Manual The White (American Standard) or Blue (European standard) wireshould be connected to the neutral lug labeled with the letter N. Finally, fix the metal cover on the casing with screws and tighten the black strain relief elements.
  • Page 13: Documentation Conventions

    SPS6000X Series User Manual secure the instrument against any unintended operation. Proper use of the instrument requires reading and understanding all of the instructions and labels. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Page 14: Informations Essentielles Sur La Sécurité

    SPS6000X Series User Manual Informations essentielles sur la sécurité Ce manuel contient des informations et des avertissements que les utilisateurs doivent suivre pour assurer la sécurité des opérations et maintenir les produits en sécurité. Exigence de Sécurité Lisez attentivement les précautions de sécurité ci - après afin d 'éviter les dommages corporels et de prévenir les dommages aux instruments et aux produits associés.
  • Page 15: Termes Et Symboles De Sécurité

    SPS6000X Series User Manual Ne pas fonctionner dans des conditions humides / humides. Pas dans un environnement explosif. Maintenez la surface de l 'instrument propre et sec. L'organisme ou l'opérateur responsable doit se référer au cahier des charges pour protéger la protection offerte par le matériel.
  • Page 16: Environnement De Travail

    SPS6000X Series User Manual Environnement de travail La conception de l'instrument a été certifiée conforme à la norme EN 61010-1, sur la base des valeurs limites suivantes: Environnement Cet instrument est utilisé à l 'intérieur des locaux et doit être utilisé dans un environnement propre et sec.
  • Page 17: Exigences De Refroidissement

    SPS6000X Series User Manual Exigences de refroidissement L 'appareil repose sur un ventilateur interne et un ventilateur de ventilation.Attention.Des mesures doivent être prises pour éviter de limiter le flux d 'air autour de l' ouverture arrière de l 'alimentation (orifice de ventilateur).Gardez une bonne ventilation lors de l 'utilisation et vérifiez régulièrement les ventilateurs et les ventilateurs.
  • Page 18: Connexion Du Port De Sortie

    SPS6000X Series User Manual Les fils noirs (norme américaine) ou bruns (norme européenne) doivent être raccordés aux languettes marquées de la lettre L. Le conducteur vert (norme américaine) ou vert - jaune (norme européenne) doit être relié au symbole de mise à la terre Les fils blancs (norme américaine) ou bleus (norme européenne) doivent être raccordés aux...
  • Page 19: Conditions Anormales

    SPS6000X Series User Manual Conditions anormales Utilisez l'instrument uniquement aux fins spécifiées par le fabricant. N'utilisez pas la lunette s'il y a des signes visibles de dommages ou si elle a été soumise à de fortes contraintes de transport. Si vous doutez que la protection de l 'alimentation électrique soit compromise, désactivez la ligne d' alimentation et fixez l 'appareil afin d' éviter toute manipulation accidentelle.
  • Page 20: Delivery Of The Power Supply

    SPS6000X Series User Manual Delivery of The Power Supply General Inspection Note: Before your first use of the equipment, please check the condition using the steps below. Inspection of transport packaging If it is found that the packing box or foam plastic pad is seriously damaged, please save it for subsequent inspection.
  • Page 21: Maintenance Agreement

    SPS6000X Series User Manual The power supply software has been fully tested and is considered to be functioning properly. However, the software is provided without any type of warranty covering detailed performance. Products not manufactured by SIGLENT are guaranteed by the OEM only.
  • Page 22: Introduction Of Sps6000X Series

    Introduction of SPS6000X Series The SIGLENT SPS6000X series is a programmable DC switching power supply with a wide range of single output and constant power features. It has a 200 V / 100 V rated output voltage value, 25 A / 50 A output current value, and 1500 W maximum output power level.
  • Page 23: Performance And Features

    SPS6000X Series User Manual 4.1 Performance and Features Rated voltage: 200 V / 100 V current: 25 A / 50 A Rated output power: 1500 W Constant power output, a wide range of voltage and current outputs, high efficiency switching...
  • Page 24: Size

    SPS6000X Series User Manual 4.2 Size This section describes the rack dimensions of the SPS6000X from the front and side, The numbers marked in the pictures are in millimeters Front dimension drawing of the SPS6000X Side dimension drawing of the SPS6000X Top view of the SPS6000X int.siglent.com...
  • Page 25: Sps6000X Series Overview

    SPS6000X Series User Manual SPS6000X Series Overview 5.1 Rack mounting The steps for installing the device on the rack are as follows: Step 1: Remove the countersunk screws fixing the small iron sheet on the left and right sides according to the figure, and move the small iron sheet outward in the direction of the arrow;...
  • Page 26 SPS6000X Series User Manual Step 4: Fix the device to the rack using screws through the screw holes on the left and right mounting ears int.siglent.com...
  • Page 27: Appearance

    SPS6000X Series User Manual 5.2 Appearance A. Screen All SPS supplies include a 3.12-inch OLED display for displaying system output status, system parameter settings, menu options, and promotion information. B. Button Used to view system information and configure power parameters.
  • Page 28: Rear Panel

    SPS6000X Series User Manual 5.3 Rear Panel Rear panels of SPS6000X series: A. Output port (positive (+), negative (-)) Positive (+) and negative (-) output terminals are used to output current and voltage. Sense terminals are used to detect the actual voltage at the load side.
  • Page 29 SPS6000X Series User Manual PS: B. Parallel interface and C. Analog control interface are protected by protective cover. As shown in the figure, the protective cover can be removed by removing the two screws fixing the protective cover; The ground installation of the protective cover is completed by securing the protective cover to the two holes shown on the bottom shell with two M3 screws int.siglent.com...
  • Page 30: Theory Of Operation

    SPS6000X Series User Manual Theory of Operation This chapter introduces the function and principles of operating the SPS6000X series power supply. 6.1 Operating Area Description SPS6000X are DC switching power supplies with high voltage and current output. All models have continuous voltage (CV) and continuous current (CC) output control modes with working ranges limited only by the output power.
  • Page 31: Slew Rate

    SPS6000X Series User Manual The power supply operates in CV or CC mode, which is determined by the set voltage (Vset), set current (Iset), load resistance (RL), and critical resistance (Rc, Rc=Vset/Iset). When RL>Rc, the power supply runs in CV mode. At this time, Vout = Vset, Iout < Iset. If RL decreases, when Iout = Iset, the power supply switches to CC mode.
  • Page 32: Bleed Circuit

    SPS6000X Series User Manual 6.4 Bleed Circuit The SPS power supplies feature a bleed resistor. When the power is turned off and the load is disconnected, the bleed resistor will consume the power in the output capacitor. Without a bleed resistor, the output capacitor will continue to be charged, causing potential danger.
  • Page 33: Considerations

    SPS6000X Series User Manual 6.6 Considerations The following conditions should be considered when using SPS power supplies: Inrush current 6.6.1 The power supply generates an inrush current when it is turned on. Ensure that the AC input power supply is sufficient at the moment of starting, especially when multiple power supplies are turned on at the same time.
  • Page 34: Reverse Current Connection Method

    SPS6000X Series User Manual As the output current is partially absorbed by the resistance, the actual Note current on load is decreased. Ensure that the resistor used can withstand the power capacity of the power supply or load. Reverse current connection method 6.6.4...
  • Page 35 SPS6000X Series User Manual Grounded output terminal If the positive/negative terminal is connected to the protective ground terminal, the insulation capacity required by the load and the load line will be greatly reduced. The insulation capacity only needs to be greater than the maximum output voltage of the power supply.
  • Page 36: Switch On / Off And Output Port

    SPS6000X Series User Manual Switch On / Off and Output Port 7.1 Connect the Power Cord The following power cord connection method: Remove the two screws, open the protective cover and follow the instructions below for wiring Turn off the power switch;...
  • Page 37: Power Off

    SPS6000X Series User Manual 7.3 Power Off Press the switch button on the panel to set the 0 position to turn off the power. It takes about 8 seconds for the power to be fully turned on and off. Warning Do not turn the power on and off quickly.
  • Page 38 SPS6000X Series User Manual Installation of the protective cover: int.siglent.com...
  • Page 39: User Interface

    SPS6000X Series User Manual User Interface User interface of the SPS6000X series: ① Output voltage value, take the average voltage. ② Output current value, take the average value of current. ③ Output power value. ④ Voltage setting value, you can set the size of the output voltage value.
  • Page 40 SPS6000X Series User Manual ⑨ Method: Press the V/I key to switch the cursor position, press the left and right direction keys to switch the cursor to the number of digits, press the up and down direction keys or turn the knob to increase or decrease the value, press the knob or SEL confirm key to confirm, and the setting is complete.
  • Page 41: Basic Operation

    SPS6000X Series User Manual Basic Operation This chapter will introduce the functions and operation methods of the control panel of SPS6000X in detail so that you can have a more comprehensive understanding of the SPS6000X for better work. 9.1 System Settings View Version Information 9.1.1...
  • Page 42: Parallel/Series Operation

    SPS6000X Series User Manual Any operation that interrupts the upgrade process may cause upgrade failure or even the machine cannot be restarted. Do not remove the USB memory device or make any changes to the power supply while updating. Parallel/Series Operation 9.1.5...
  • Page 43 SPS6000X Series User Manual Parallel between multiple SPS6000X supplies 9.1.5.2 Mode setting Setting method: Menu → 2.Configure → 8.Share Bus mode to enter the setting interface. Turn the knob or press the direction keys to select the configuration of the slave/slave mode Press the knob or SEL key to make the setting effective.
  • Page 44 SPS6000X Series User Manual When the product is output in parallel, the slave machine remains in the open state, and the Master (supply A) has output control of the whole parallel system. Pin number Description 1, 2, 9, 10 Parellel_I Parallel current pin...
  • Page 45: Function Settings

    SPS6000X Series User Manual 9.2 Function Settings Set List Function 9.2.1 Press the List key directly on the operation panel to enter the List setting interface, and press the List key again to exit the List mode: The main interface of the List function ①...
  • Page 46: Set Ocp/Ovp

    SPS6000X Series User Manual ① Number of cycles. Set the number of output cycles for the total number of steps (maximum 9999), and INF is infinite cycle. ② Total steps. ③ The number of steps of the current operation. 01 represents the first step.
  • Page 47: Set Cc/Cv Priority

    SPS6000X Series User Manual Setting method: Press the knob or SEL key on the setting interface, move the cursor to the shadow overlay On/Off. Turn the knob or SEL key to select On or Off. Press the knob to confirm and the setting will take effect.
  • Page 48: Set Measurement Accuracy

    SPS6000X Series User Manual Menu → 2.Configure → 3.Output delay to enter the setting interface. Press the up and down direction keys or turn the knob to switch the setting of on delay or off delay. Press the left or right direction keys to switch the number of digits, and press the up and down direction keys or turn the knob to change the value.
  • Page 49: External Analog Control

    SPS6000X Series User Manual External Analog Control 9.2.6 There are two working modes for external analog control. Voltage controls voltage and voltage controls current. The output value can be controlled through the ports on the rear panel. In the external...
  • Page 50: External Control Output On/Off

    SPS6000X Series User Manual External Control Output On/Off 9.2.7 When set to Ext_ctrl_enable, the Output key on the front panel is invalid. The output is controlled by the rear analog interface pin 19 high-level effective control, and the reference ground is pin 17 (COM).
  • Page 51 SPS6000X Series User Manual Select the corresponding mode and press the knob or SEL key again to select Internal or External. If stored in Internal, 9 groups of data can be stored. ☑ indicates that data items have been saved. To replace data items, select the data item with ☑ and press the knob or SEL key to overwrite it.
  • Page 52: Analog Interface

    SPS6000X Series User Manual Analog Interface 9.2.9 Description of the SPS6000X analog interface pins Pin number Description When a low TTL signal is applied to this pin, the output will be closed. This pin is pulled up to 5V with a 10kΩ resistor.
  • Page 53 SPS6000X Series User Manual When the EXT_ON/OFF is open, a 5V or 0V voltage applied to this pin will control the source on, off or hold. In the CV state, this pin is low impedance to pin 17. (photo coupled open collector out) int.siglent.com...
  • Page 54: Communication Interface Settings

    SPS6000X Series User Manual 10 Communication interface settings USB cannot be edited, only viewing operations can be performed. Operation method: Menu → 3.Communication → 1.USB . After entering the interface, you can view the resource information of the USB device.
  • Page 55 SPS6000X Series User Manual Press the knob or SEL key to enter the setting, press the left and right direction keys or turn the knob to switch bits, press the up and down direction keys or turn the knob to change the size of the value.
  • Page 56: Recalibration Setting

    SPS6000X Series User Manual 11 Recalibration setting The SPS6000X supports manual recalibration. Users can select default data or customized data to recalibrate the machine. Factory Settings ensure one-year accuracy. Recommended calibration frequency: 1 time/year Calibrate voltage/current Setting method: Menu → 4. Calibrate device → Voltage Calibration/Current Calibration to enter the voltage/current calibration interface.
  • Page 57: Remote Control

    SPS6000X Series User Manual 12 Remote Control The SPS6000X supports communication with a computer via USB, LAN, and GPIB-USB interfaces using a SCPI (Standard Commands for Programmable Instruments) compliant command set. This chapter will introduce how to build a programming environment and explain the SCPI commands supported by the SPS6000X.
  • Page 58: Grammatical Conventions

    SPS6000X Series User Manual 12.2 Grammatical Conventions SCPI commands are a tree-like hierarchical structure, including multiple subsystems. Each subsystem is composed of a root keyword and one or several hierarchical keywords. Command keywords are separated by colons ‘ : ’, keywords are followed by optional parameter settings, commands and parameters are separated by ‘...
  • Page 59: Command Description

    SPS6000X Series User Manual 12.4 Command Description 12.4.1 IEEE Common Command Subsystem *IDN? 12.4.1.1 Command format: *IDN? Description: Get device information string (return string content includes: manufacturer, device model, device serial port number, and the software version number) E.g: *IDN? Response: Siglent Technologies, SPS6225X, SPS5X2022008, 1.1.1.5\n...
  • Page 60 SPS6000X Series User Manual *ESR? 12.4.1.6 Command format: *ESR? Description: Query and clear the event value of the standard event status register. E.g: *ESR? Response: *OPC 12.4.1.7 Command format: *OPC Description: Operation complete. E.g: *OPC *OPC? 12.4.1.8 Command format: *OPC? Description: Query whether the current operation is complete.
  • Page 61: Source Command Subsystem

    SPS6000X Series User Manual Description: Query the event value of the status byte register E.g: *STB? Response: 12.4.1.12 *TST? Command format: *TST? Description: Query the result of instrument self-test E.g: *TST? Response: 12.4.1.13 *WAI Command format: *WAI Description: Wait for all outstanding operations to complete before executing any other commands E.g:...
  • Page 62 SPS6000X Series User Manual Set OVP value 12.4.2.2 Command format: [:SOURce]:OVP {<value> | MINimum | MAXimum |DEFault} Description: Set the overvoltage value of the channel E.g: :SOURce:OVP 25 Description: Set the OVP value to 25V Command format: [:SOURce]:OVP? Description: Get the overvoltage value of the channel E.g:...
  • Page 63 SPS6000X Series User Manual Description: Get the voltage drop slope value of the channel E.g: :SOURce:VOLTage:FALL:SLOPe? Response: 4.000000\n Set the voltage response change mode 12.4.2.5 Command format: [:SOURce]:VOLTage[:RESPonse]:MODE {FAST| SLOPE} Description: Set the voltage response change mode of the channel (FAST / SLOPE) E.g:...
  • Page 64 SPS6000X Series User Manual E.g: MEASure:VOLTage? CH1 Response: 2.991442\n Set current value 12.4.2.8 Command format: [:SOURce]:CURRent[:SET] <channel>, {<value> | MINimum | MAXimum |DEFault} Description: Set the current value of the channel E.g: :SOURce:CURRent:SET CH1,2 Description: Set the CH1 channel current value to 3V Command format: [:SOURce]:CURRent[:SET]? <channel>...
  • Page 65 SPS6000X Series User Manual E.g: :SOURce:CURRent:RISE:SLOPe 0.3 Description: Set the current rising slope to 0.3A/ms Command format: [:SOURce]:CURRent:RISE:SLOPe? Description: Get the current rising slope value of the channel E.g: :SOURce:CURRent:RISE:SLOPe? Response: 0.300000\n 12.4.2.11 Set current falling slope Command format: [:SOURce]:CURRent:FALL:SLOPe {<value>...
  • Page 66 SPS6000X Series User Manual Response: Fast priority\n 12.4.2.13 Set OPP value Command format: [:SOURce]:OPP {<value> | MINimum | MAXimum |DEFault} Description: Set the overpower value of the channel E.g: :SOURce:OPP 500 Description: Set the OPP value to 500W Command format:...
  • Page 67 SPS6000X Series User Manual Command format: [:SOURce]:CTRL:CURRent:MODE? Description: Get the current control mode of the channel E.g: :SOURce:CTRL:CURRent:MODE? Response: LOCAL\n 12.4.2.16 Set external output enable state Command format: [:SOURce]:CTRL:EXT:STATe {OFF | ON | TRIG | 0 | 1 | 2 }...
  • Page 68 SPS6000X Series User Manual Description: Set the delay time of the output ON of the channel E.g: OUTPut:ON:DELay 3 Description: Set the output ON delay to 3 seconds Command format: [:SOURce]:OUTPut:ON:DELay? Description: Obtain the delay time of the channel's output ON E.g:...
  • Page 69 SPS6000X Series User Manual Response: NORMAL MODE \n 12.4.2.21 Set channel CC/CV priority mode Command format: [:SOURce][:CVCC]:PRIOrity {CC | CV } Description: Set the CC/CV priority of the channel (CC | CV) E.g: :SOURce: PRIOrity CC Description: Set the operation mode to CC priority...
  • Page 70 SPS6000X Series User Manual 12.4.2.24 Set channel List mode status Command format: [:SOURce]:LIST[:STATe] { OFF | ON | 0 | 1} Description: Set the List mode status of the channel (OFF | ON | 0 | 1) E.g: LIST 1...
  • Page 71 SPS6000X Series User Manual Description: Get the number of List steps of the channel E.g: :SOURce:LIST:STEP? Response: 12.4.2.27 Set the voltage value of the specified steps of List Command format: [:SOURce]:LIST:VOLTage <step>, {<value> | MINimum | MAXimum |DEFault} Description: Set the voltage setting value of the current step number of the channel List E.g:...
  • Page 72 SPS6000X Series User Manual 12.4.2.29 Set the running time of the specified steps of List Command format: [:SOURce]:LIST:WIDth <step>,<value> Description: Set the running time of the current step number of the channel List E.g: :SOURce:LIST:WIDTh 1,5 Description: Set the running time of step 1 to 5 seconds Command format: [:SOURce]:LIST:WIDth? <step>...
  • Page 73 SPS6000X Series User Manual E.g: :SOURce:LIST:SLOPe:CTRL:MODE? 1 Response: Fast priority\n 12.4.2.32 Set the voltage rise slope of the specified steps of List Command format: [:SOURce]:LIST:VOLTage:RISE:SLOPe <step>,<value> Description: Set the voltage rise slope value of the channel steps in list mode E.g:...
  • Page 74 SPS6000X Series User Manual Description: Set the current rise slope of step 1 of channel 1 to 0.3A /ms Command format: [:SOURce]:LIST:CURRent:RISE:SLOPe? <step> Description: Obtain the current rise slope value of the channel steps in list mode E.g: :SOURce:LIST:CURRent:RISE:SLOPe? 1 Response: 0.300000\n...
  • Page 75: System Configuration Command Subsystem

    SPS6000X Series User Manual 12.4.2.37 Query output remains unchanged Command format: [:SOURce]:LOCK[:STATe] { OFF | ON | 0 | 1} Description: Query output remains unchanged status (when Ext_trigger mode is selected by external control) E.g: :SOURce:OUTPut:KEEP:STATe? Response: OFF\n Command format:...
  • Page 76 SPS6000X Series User Manual Command format: MENU:SOUNd:ALARm? Description: Get warning sound switch status E.g: MENU:SOUNd:ALARm? Response: Set OCP switch state 12.4.3.3 Command format: SYStem:OCP:STATe{ OFF | ON | 0 | 1} Description: Set the ocp switch state of the channel E.g:...
  • Page 77 SPS6000X Series User Manual Description: Get dynamic IP status E.g: DHCP? Response: Set IP address 12.4.3.6 Command format: [:SYStem]:LAN:IPADdress <value> Description: Set IP address E.g: LAN:IPADdress 10.11.13.213 Command format: [:SYStem]:LAN:IPADdress? Description: Get IP address E.g: LAN:IPADdress? Set the subnet mask 12.4.3.7...
  • Page 78 SPS6000X Series User Manual E.g: LAN:GATeway? Set MAC address 12.4.3.9 Command format: [:SYStem]:LAN:MAC <value> Description: Set MAC address E.g: LAN:MAC 00:00:00:00:a0:42 Command format: [:SYStem]:LAN:MAC? Description: Get MAC address E.g: LAN:MAC? 12.4.3.10 Set GPIB address Command format: [:SYStem]:GPIB:ADDRess <value> Description: Set GPIB address E.g:...
  • Page 79: Measure Configuration Command Subsystem

    SPS6000X Series User Manual 12.4.3.13 Get slave version information Command format: SYStem:SLAVE:VERsion? Description: Get the channel slave version E.g: SYStem:SLAVE:VERsion? 12.4.4 Measure Configuration Command Subsystem Get the measured voltage value 12.4.4.1 Command format: MEASure:VOLTage? Description: Get the voltage measurement value of the channel E.g:...
  • Page 80: Storage Configuration Command Subsystem

    SPS6000X Series User Manual 12.4.5 Storage Configuration Command Subsystem Get the specified generic data file 12.4.5.1 Command format: [:STORage]:FILE:DATA:STATE? Description: Get whether the specified generic data file is valid E.g: :STORage:FILE:DATA:STATE? 1 Response: Exist \n Load the specified generic data file 12.4.5.2...
  • Page 81 SPS6000X Series User Manual Description: Load the specified List data file with NO.1 Save the current List data to the specified List generic data file 12.4.5.6 Command format: [:STORage]:FILE:LIST:SAVE Description: Save the current LIST data to the specified LIST data file E.g:...
  • Page 82: Web Service

    SPS6000X Series User Manual 12.5 Web Service The SPS6000X can be remotely controlled through its embedded web control interface. The first connection method: The computer is not connected to the network, and the SPS6000X and the computer are directly connected through a network cable(cross-over cable). First, set up the computer. The following uses...
  • Page 83 SPS6000X Series User Manual ① Set an IP address different from SPS ② Set the same subnet mask as SPS ③ Set the same gateway as SPS Set the SPS power supply Refer to the previous chapter [9.3.3] LAN settings, manually set SPS to be the same as the PC computer subnet mask and default gateway, and set a different IP address.
  • Page 84 SPS6000X Series User Manual Operating: Click [Configure] in the left column to switch to the configuration interface After performing function configuration on the Configure interface, you need to click Submit at the arrow to send the data to the power supply.
  • Page 85: List Operation Method

    SPS6000X Series User Manual 12.5.1 List operation method: Set the channel mode to List mode. Select List, click Submit Add the number of List steps Set the voltage and current parameters of each step, and click Download after the output is completed to send the List data to the power supply Turn on the Output switch of the channel and click Submit.
  • Page 86 SPS6000X Series User Manual power supply sets the output according to the number of List steps, and the setting is completed. int.siglent.com...
  • Page 87: List File Export

    SPS6000X Series User Manual 12.5.2 List file export The SPS webpage supports exporting the settings of the voltage, current, delay time, running time, and slope of the List steps to the outside in the form of .csv, and click Export to start the export operation.
  • Page 88: Troubleshooting

    SPS6000X Series User Manual 13 Troubleshooting The following lists the power supply in the use of the process of possible failures and troubleshooting. When you encounter these faults, please follow the corresponding steps to deal with them. If you can't handle them, please contact siglent in time.
  • Page 89 SPS6000X Series User Manual About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended...