Connecter l'alimentation ......................11 Nettoyage .............................11 Delivery of The Power Supply................12 General Inspection ......................12 Quality Assurance.......................12 Maintenance Agreement ....................13 Introduction of SPD4000X Series ............... 14 Brief Introduction.........................14 Performance and Features ....................15 Mechanical Dimension .......................16 Quick Start ......................17 Front Panel .........................17 Rear Panel ..........................20...
Page 4
SPD4000X Series User Manual Output Settings ........................28 8.1.1 Set Output Voltage/Current ..................28 8.1.2 Set OVP/OCP ......................29 Configure Settings ......................29 8.2.1 On/Off Delays ......................29 8.2.2 Output Mode ......................30 List Setting ..........................33 Waveform Display.......................34 Sense Setting ........................35 Menu Function Operations ................. 37 System Settings ........................37...
Page 5
SPD4000X Series User Manual 10.4.6 CALIBRATE Subsystem ..................68 10.4.7 MEASURE Subsystem ...................69 10.5 Web Service ........................70 10.5.1 Web Connection Method ..................70 10.5.2 Web Interface ......................72 10.5.3 List Operation Method ....................73 10.5.4 Import/Export List File ....................74 11 Troubleshooting ....................75 int.siglent.com...
SPD4000X Series User Manual Introduction This user manual includes important safety and installation information related to the SPD4000X series programmable linear DC power supply and includes simple tutorials for the basic operation of the supply. int.siglent.com...
SPD4000X Series User Manual Important Safety Information This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition. 2.1 General Safety Summary Please review the following safety precautions carefully to avoid personal injury or damage to this product or any product connected to it.
Page 9
SPD4000X Series User Manual Do not operate in wet/damp conditions. Keep the surface of the instrument clean and dry. Electrostatic Prevention. Operate in an electrostatic-protected area environment to avoid damages induced by static discharge. Always ground both the internal and external conductors of the cable to release a static charge before connecting.
SPD4000X Series User Manual Safety Terms and Symbols When the following symbols or terms appear on the front or rear panel of the instrument or in this manual, they indicate special care in terms of safety. This symbol is used where caution is required. Refer to the accompanying information or documents to protect against personal injury or damage to the instrument.
SPD4000X Series User Manual Working Environment This instrument is intended for indoor use and should be operated in a clean, dry environment. Relative Humidity: ≤ 80% • Altitude: ≤ 2000m • • Ambient temperature: 0℃ ~ 40℃ Note: Direct sunlight, radiators, and other nearby heat sources should be taken into account when assessing the ambient temperature.
SPD4000X Series User Manual Connect Power Input Power Requirement The SPD4000X allows a 50Hz/60Hz frequency, and four levels of AC power: 100V/120V/220V/230V±10%. You can select wanted power voltage with the "DIP Switch" at the rear panel according to the actual demand.
SPD4000X Series User Manual Document Conventions For convenience, text with character borders is used to represent the buttons on the front panel. For example, Home represents the "Home" button on the front panel. Italicized text with shading is used to represent the clickable menu/options/virtual keys on the display. For example, Source represents the "Source"...
SPD4000X Series User Manual Informations de sécurité importantes Ce manuel contient des informations et des avertissements que l'utilisateur doit suivre pour assurer un fonctionnement sûr et maintenir le produit dans un état sûr. Résumé général de la sécurité Veuillez examiner attentivement les précautions de sécurité ci - dessous pour éviter des blessures ou des dommages corporels à...
SPD4000X Series User Manual Ne pas utiliser sans couvercle. N'utilisez pas l'instrument sans retirer le couvercle ou le panneau. Ne placez pas d'objets lourds sur le SPD4000X. Évitez les impacts graves ou les placements inappropriés qui pourraient endommager l'alimentation. Ne placez pas d'objets lourds sur l'alimentation.
SPD4000X Series User Manual Environnement de travail Cet instrument est adapté à une utilisation en intérieur et doit être utilisé dans un environnement propre et sec. Humidité relative: ≤80% • Altitude: ≤2000m • • Température ambiante: 0℃ ~ 40℃ Remarque: la lumière directe du soleil, les radiateurs et les autres sources de chaleur à proximité...
SPD4000X Series User Manual Connecter l'alimentation Le SPD4000x permet des fréquences de 50Hz / 60Hz et quatre niveaux d'alimentation AC: 100V / 120V / 220V / 230V ± 10%. Vous pouvez sé lectionner la tension d'alimentation souhaitée avec le "DIP SWITCH" sur le panneau arrière en fonction des besoins réels.
SPD4000X Series User Manual Delivery of The Power Supply General Inspection Please check the instrument according to the following steps. Inspect the shipping container Keep the original shipping container and cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests.
SPD4000X Series User Manual Maintenance Agreement We provide various services based on maintenance agreements. We offer extended warranties as well as installation, training, enhancement and on-site maintenance, and other services through specialized supplementary support agreements. For details, please consult your local SIGLENT customer service center or distributor.
The instrument is also equipped with LAN/USB communication interface and remote web page control function to meet different application scenarios. The rated output value of each model of SPD4000X series is shown in the following table: Model SPD4323X...
SPD4000X Series User Manual Performance and Features • Rated voltage: 32V, 12V, 30V; rated output power: 240W, 285W, 400W • Up to four high-precision power supplies with independent controllable outputs, supporting CH2 and CH3 series and parallel connections • Clear graphical interface with waveform and timer display modes •...
SPD4000X Series User Manual Quick Start Front Panel Display area Shortcut function buttons Menu buttons Channel control buttons Numeric keypad Output terminals Knob Ground terminal Right/left direction button 10. Power switch int.siglent.com...
Page 24
SPD4000X Series User Manual Front panel description: Item Description Equipped with a 4.3-inch TFT LCD display, used to display system Display area output state, system parameter settings, menu options, and promotion information, etc. Menu buttons Access the display interface menu.
Page 25
SPD4000X Series User Manual Item Description The SPD4000X has four output terminals, which can be Output terminals independently output, CH2/3 series output and CH2/3 parallel output. Ground terminal Used to connect the shell ground. Power switch Turn on/off the power.
SPD4000X Series User Manual Rear Panel Warning message AC power socket and AC input voltage description Lan port Fan vents Ground port Certification mark USB ports 10. Device lock CH2/3 sense port The DIP switch of the AC power and its identification...
SPD4000X Series User Manual Switch On/Off Connect the Power The specifications of the input AC power supply are as follows: AC 100V/120V/220V/230V± 10%, 50/60Hz. Please use the power cable provided in the attachment to connect the SPD4000X to the power supply.
SPD4000X Series User Manual Interface Introduction User Interface Channel logo. CH2/CH3 working state: 2W or 4W. Operating mode logo. The corresponding logo will display when working in CV or CC mode. Output value. Display the current actual output voltage and current.
SPD4000X Series User Manual Menu Functions Item Description • Voltage: Set the voltage value • Current: Set the current value • OV Protection: Set the OVP value, 0.1~1.1 times rated voltage can be set • OCP State:Turn on/off OCP function. You can use Enter button or F1 to make a quick selection ON: Turn on OCP;...
Page 30
SPD4000X Series User Manual Item Description • Continuous: Continuous loop the list • Next Page: Go to the next page • Clear All: Clear all steps in the list after confirming the setting in the pop-up window • Add: Add a step to the list •...
Page 31
SPD4000X Series User Manual Item Description Off: Turn off key sound Alarm Sound On: Turn on alarm sound Off: Turn off alarm sound Board Test: Keyboard: Keyboard test. The corresponding keys display on the interface will be filled for keyboard test, and the corresponding block of the key will light up in response ...
Page 32
SPD4000X Series User Manual Item Description MAC Address GBIP: Set the GPIB address value Default Settings: Restore default settings (channel parameter Default settings) Setting Factory Settings: Restore factory settings (all settings) Universal save recall: Save: Save the data to native internal storage ...
Page 33
SPD4000X Series User Manual Item Description Voltage Calibrate Current Calibrate Clear CALI data: Clear the current calibration data Clear all data: Clear all calibration data Back CH2 Sense: Turn on/off CH2 sense Sense ...
SPD4000X Series User Manual Basic Operation Output Settings 8.1.1 Set Output Voltage/Current The output voltage and current values can be set in the SET area of the user interface, or in the source setting interface. Method 1: Set in the SET area of the user interface Select an output channel: Press the channel control button or press the left/right direction button to select the current operation channel.
SPD4000X Series User Manual 8.1.2 Set OVP/OCP The SPD4000X equipped with overvoltage protection (OVP) and overcurrent protection (OCP) functions. OVP setting method: Press Source corresponding menu button on the panel to enter the source setting interface. Press the left/right direction button to select "OV Protection", and use the numeric keypad or knob to set the value.
SPD4000X Series User Manual 8.2.2 Output Mode The SPD4000X has four sets of independently adjustable output sources, each output source supports constant voltage and constant current modes. The CH1/CH4 of the SPD4000X have only one independent output mode, and the CH2/CH3 have three output modes: independent, parallel and series.
Page 37
SPD4000X Series User Manual Connect the load to the terminals on the front panel: CH1 +/-, CH2 +/-, CH3 +/-, CH4 +/-. Set voltage and current value of CH1/CH2/CH3/CH4: Press 1 / 2 / 3 / 4 button to select the wanted channel...
Page 38
SPD4000X Series User Manual CH2/CH3 Series Mode In the series mode, the voltage value is twice compared with that of single channel. CH2/3 are linked internally into one channel which is controlled by CH2, and CH2 reads the parallel voltage and current values.
SPD4000X Series User Manual List Setting Press List corresponding menu button on the panel to enter the output list setting interface and set the list. Step Voltage: Set the output voltage corresponding to the number of steps. Select the number of steps you want to set and use the numeric keypad or knob to set the value Current: Set the output current corresponding to the number of steps.
SPD4000X Series User Manual Waveform Display SPD4000X can display the changes of the output voltage and current of the channel in real time through the form of curve plotting. Setting method: Set channel output parameters. Press Wave corresponding menu button on the panel to enter the waveform display interface.
SPD4000X Series User Manual Return to the waveform display interface, press the ON button corresponding to the selected channel to open the channel output, and then you can observe the real-time change of output parameters (voltage/current). Note: The color of the output parameter waveform curve corresponds to the color of the channel.
Page 42
SPD4000X Series User Manual Self made voltage sense wires, requiring a metal conductive tail, with a recommended length of 1cm. Place the tail end at the corresponding position of the voltage sensing connector, tighten the corresponding upper screw with a screwdriver, and secure the wiring. After connecting the wires, insert the voltage sensor into the rear panel of the machine, tighten the screws on both sides with a screwdriver, and secure the connector.
SPD4000X Series User Manual Menu Function Operations System Settings 9.1.1 View Version Information Press Menu > System corresponding menu button on the panel to select Version through the left/right direction button. Press Enter button to enter the version information display interface.
SPD4000X Series User Manual 9.1.3 Board Test Press Menu > System corresponding menu button on the panel to select Board Test through the left/right direction button. Press Enter button to enter the board test interface, where you can test the keyboard, LED and sound.
SPD4000X Series User Manual 9.1.4 System Upgrade Please follow the steps below to upgrade the firmware: Download the firmware upgrade package from the official website. Copy the .ADS file in the upgrade package to the root directory of the U disk.
SPD4000X Series User Manual Press the right/left direction button or press DHCP corresponding menu button on the panel to keep the cursor on the DHCP line, and then press Enter button to set DHCP to ON or OFF. ON: The SPD4000X automatically sets its IP address, subnet mask, and gateway based on the network it is connected to.
SPD4000X Series User Manual Default Setting Operations 9.3.1 Default Settings Press Menu > Default Setting corresponding menu button on the panel, and select Default Settings through the left/right direction button. Press the Enter button to confirm the selection, and complete the default settings according to the pop-up prompt.
SPD4000X Series User Manual 9.3.2 Factory Settings Setting method: Press Menu > Default Setting corresponding menu button on the panel, and select Factory Settings through the left/right direction button. Press the Enter button to confirm the selection, and complete the factory settings according to the pop-up prompt.
Page 49
SPD4000X Series User Manual Save: Save the data to native internal storage Recall: Recall the data from native internal storage Delete: Delete the saved data External Save: Save the data to external storage External Recall: Recall the data from external storage Save the data to native internal storage.
SPD4000X Series User Manual prompt window "Recall successfully" will pop up when the file is recalled successfully. Recall the data from external storage. Press the External Recall corresponding menu button on the panel to recall the selected file to recall the data stored on an external U disk.
Page 51
SPD4000X Series User Manual Save the list data to native internal storage. Press the left/right direction button to select a file saving location (List file1 ~ List file8), and press the Save corresponding menu button on the panel to save the current settings on the native internal storage.
SPD4000X Series User Manual Calibration The SPD4000X supports manual calibration, users can recalibrate the instrument by using the factory calibration data or custom calibration data. Factory setting guarantees one year accuracy, and the recommended calibration frequency is 1 time/year. 9.5.1 Select Calibrate Source Press Menu >...
SPD4000X Series User Manual 9.5.2 Volt/Curr Calibration Press Menu > Calibrate Device corresponding menu button on the panel, select Volt/Curr calibrate through the left/right direction button, and then press the Enter button to enter the Volt/Curr calibration interface. Select a channel that you want to Calibrate by pressing the channel control button. Press...
SPD4000X Series User Manual 10 Remote Control The SPD4000X supports communication with a computer via USB and LAN interfaces using a SCPI (Standard Commands for Programmable Instruments) compliant command set. This chapter will introduce how to build a programming environment and explain the SCPI commands supported by the SPD4000X.
SPD4000X Series User Manual 10.2 Grammatical Conventions SCPI commands are a tree-like hierarchical structure, including multiple subsystems. Each subsystem is composed of a root keyword and one or several hierarchical keywords. Command keywords are separated by colons ‘ : ’, keywords are followed by optional parameter settings, commands and parameters are separated by ‘...
SPD4000X Series User Manual 10.4 Command Description 10.4.1 IEEE Common Command Subsystem *IDN? Command format *IDN? Query the manufacturer, device model, device serial port number, Description software version number Example *IDN? Response Siglent\sTechnologies,SPD4306X,0123456789,4.1.2.4\n *RST Command format *RST Description Restore the state of the device to the initial state...
Page 57
SPD4000X Series User Manual *ESR? Command format *ESR? Description Query and clear the event value of the standard event status register Example *ESR? Response *OPC Command format *OPC Description Operation complete Example *OPC *OPC? Command format *OPC? Description Query whether the current operation is complete...
SPD4000X Series User Manual 11. *STB? Command format *STB? Description Query the event value of the status byte register Example *STB? Response 12. *TST? Command format *TST? Description Query the result of instrument self-test Example *TST? Response 13. *WAI Command format...
Page 59
SPD4000X Series User Manual Set OVP value Command format [:SOURce]:OVP (CHn),{<value> | MINimum | MAXimum |DEFault} Description Set the OVP value of the selected channel Example :SOURce:OVP CH1,8 Description Set the OVP value of CH1 to 8V Command format [:SOURce]:OVP? (CHn)
Page 60
SPD4000X Series User Manual Set OCP value Command format [:SOURce]:OCP (CHn),{<value> | MINimum | MAXimum |DEFault} Description Set the OCP value of the selected channel Example :SOURce:OCP CH1,8 Description Set the OCP value of CH1 to 8A Command format [:SOURce]:OCP? (CHn)
Page 61
SPD4000X Series User Manual Set OCP switch state Command format [:SOURce]:OCP:STATe (CHn),{ON | OFF | 0 | 1} Description Set the OCP switch state of the selected channel Example :SOURce:OCP:STATe CH1, 1 Description Set the OCP switch state of CH1 to ON...
Page 62
SPD4000X Series User Manual 11. Set output ON delay value of the channel [:SOURce]: OUTPut:ON:DELay (CHn) ,{<value> | MINimum | Command format MAXimum |DEFault} Description Set output ON delay value of the selected channel Example OUTPut:ON:DELay CH1,3 Description Set output ON delay value of CH 1 to 3s...
Page 63
SPD4000X Series User Manual Command format [:SOURce]:OUTPut:TRACK? Description Query the selected output mode of CH2/3 Example OUTPut:TRACK? Response 14. Set working mode Command format [:SOURce]:MODE {CH2|CH3},{0 | 1| 2W| 4W} Description Set the working mode of the selected channel Example...
Page 64
SPD4000X Series User Manual 16. Set list current Command format [:SOURce]:LIST:CURRent (CHn),<value1>,<value2>,…,<valuen> Description Set the current value of the first n steps of the selected channel Example LIST:CURR CH1,0.1,0.2,0.3,0.4,0.5 Set the current value for the first 5 steps of CH 1 to 0.1A, 0.2A, 0.3A, Description 0.4A, 0.5A...
Page 65
SPD4000X Series User Manual 19. Set the number of cycles [:SOURce]:LIST:CYCLes [:COUNt] (CHn),{<value> | MINimum | Command format MAXimum |DEFault} Description Set the number of cycles Example LIST:CYCLes CH1,1 Description Set the number of cycles of the list for CH 1 to 1...
Page 66
SPD4000X Series User Manual Command format [:SOURce]:LIST:RUN[:State]? (CHn) Description Get the running state of the list for the channel Example LIST:RUN? CH1 Response 22. Set the running state of the list for all channels Command format [:SOURce]:LIST:RUN:ALL[:State] {OFF | ON | 0 | 1}...
Page 67
SPD4000X Series User Manual 25. Query the running state information of the list for a channel Command format [:SOURce]:LIST:INFOrmation[:State]? (CHn) Get the running state information of the list for a channel, include the number of steps currently running, the running state, the wait state, the...
SPD4000X Series User Manual 10.4.3 WAVE Subsystem Set waveform drawing state for a channel Command format WAVE:DRAW[:STATe] (CHn),{VOLT | CURR },{ OFF | ON | 0 | 1} Description Set the channel waveform drawing state Example WAVE:DRAW[:STATe] CH1,VOLT,1 Description Set the CH 1 voltage waveform drawing state to ON...
Page 69
SPD4000X Series User Manual Set waveform sampling period Command format WAVE:SAMPle[:PERIod] <value> Description Set waveform sampling period Example WAVE:SAMPle 200 Description Set waveform sampling period to 200ms Command format WAVE:SAMPle[:PERIod]? Description Query waveform sampling period Example WAVE:SAMPle[:PERIod]? Response 200\n Set waveform saving switch state...
SPD4000X Series User Manual 10.4.4 SYSTEM Subsystem Set key sound Command format [:SYStem]:SOUNd:KEY {OFF | ON | 0 | 1} Description Set the key sound switch state Example SOUNd:KEY 1 Description Set the key sound switch state to ON Command format...
Page 71
SPD4000X Series User Manual Set DHCP Command format [:SYStem]:DHCP {OFF | ON | 0 | 1} Description Set to obtain IP address dynamically or manually Example DHCP 1 Description Set to obtain IP address dynamically Command format [:SYStem]:DHCP? Description Get the switch state of DHCP...
Page 72
SPD4000X Series User Manual Set gateway Command format [:SYStem]:LAN:GATeway <value> Description Set the gateway Example LAN:GATeway 10.11.13.1 Command format [:SYStem]:LAN:GATeway? Description Get the gateway Example LAN:GATeway? Get MAC address Command format [:SYStem]:LAN:MAC? Description Get MAC address Example LAN:MAC? Set GPIB address Command format [:SYStem]:GPIB:ADDRess <value>...
SPD4000X Series User Manual 10.4.5 STORAGE Subsystem Get whether the specified universal data file is valid Command format [:STORage]:UNIVersal:FILE:STATe? Description Get whether the specified universal data file is valid Example :STORage:UNIVersal:FILE:STATe? 1 Response Exist\n Recall the specified universal data file...
SPD4000X Series User Manual Recall the specified list data file Command format [:STORage]:LIST:FILE:RECAll Description Recall the specified LIST data file Example :STORage:LIST:FILE:RECAll 1 Description Recall the specified LIST data file with serial number 1 Save the current list data to the specified list data file...
SPD4000X Series User Manual 10.4.7 MEASURE Subsystem Get the measured voltage value Command format MEASure:VOLTage? (CHn) Description Get the voltage measurement value of the selected channel Example MEASure:VOLTage? CH1 Response 2.991442\n Get the measured current value Command format MEASure:CURRent? (CHn)
SPD4000X Series User Manual 10.5 Web Service 10.5.1 Web Connection Method The SPD4000X can be remotely controlled through its embedded web control interface. The first connection method: The computer is not connected to the network, and the SPD4000X and the PC computer are directly connected through a network cable (cross-over cable).
Page 77
SPD4000X Series User Manual Select "Use the following IP address" to set the IP address, subnet mask and default gateway, and click "OK" after setting. A. Set an IP address different from SPD B. Set the same subnet mask as SPD C.
SPD4000X Series User Manual Set the SPD3004X: Refer to the previous chapter "9.2.2 LAN Setting", manually set SPD4000X to be the same as the PC computer subnet mask and default gateway, and set a different IP address. At this point, the PC and SPD4000X settings are completed, and the web page can be opened for remote control.
SPD4000X Series User Manual Click "About" in the left column to view device information. 10.5.3 List Operation Method Select the channel for which you want to set the list. Add the number of list steps and set whether to loop the list. If the cyclic list is used, you need to set the number of cycles.
SPD4000X Series User Manual Turn on the "Output" switch of the channel and click "Submit". The SPD4000X will output according to the settings of the list steps. 10.5.4 Import/Export List File The SPD4000X supports exporting the settings of the voltage and current of the list steps to the outside storage in the form of .csv, and click "Export "to start the export operation.
SPD4000X Series User Manual 11 Troubleshooting The following lists the power supply in the use of the process of possible failures and troubleshooting. When you encounter these faults, please follow the corresponding steps to deal with them. If you can't handle them, please contact SIGLENT in time.
Page 82
SPD4000X Series User Manual About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended...
Need help?
Do you have a question about the SPD4000X Series and is the answer not in the manual?