Fujitsu AIRSTAGE UTY-SPWX Installation Manual
Fujitsu AIRSTAGE UTY-SPWX Installation Manual

Fujitsu AIRSTAGE UTY-SPWX Installation Manual

Pressure sensor kit

Advertisement

Quick Links

UTY-SPWX
INSTALLATION MANUAL
For authorized service personnel only.
INSTALLATIONSANLEITUNG
Nur für autorisiertes Fachpersonal.
MANUEL D'INSTALLATION
KIT DE CAPTEUR DE PRESSION
Pour le personnel agréé uniquement.
MANUAL DE INSTALACIÓN
KIT DE SENSORES DE PRESIÓN
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
KIT SENSORI DI PRESSIONE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
KIT DE SENSOR DE PRESSÃO
Apenas para técnicos autorizados.
РУКОВОДСТВО ПО УСТАНОВКЕ
КОМПЛЕКТ ДАТЧИКА ДАВЛЕНИЯ
Только для авторизованного обслуживающего персонала.
MONTAJ KILAVUZU
Yalnızca yetkili servis personeli için.
仅针对授权的专业维修人员。
PRESSURE SENSOR KIT
DRUCKSENSOR SATZ
ΚΙΤ ΑΙΣΘΗΤΗΡΑ ΠΙΕΣΗΣ
BASINÇ SENSÖRÜ KİTİ
安装说明书
安装说明书
压力传感器组件
[Original instructions]
PART No. 9374707218-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIRSTAGE UTY-SPWX and is the answer not in the manual?

Questions and answers

Summary of Contents for Fujitsu AIRSTAGE UTY-SPWX

  • Page 1 INSTALLATION MANUAL PRESSURE SENSOR KIT For authorized service personnel only. INSTALLATIONSANLEITUNG DRUCKSENSOR SATZ Nur für autorisiertes Fachpersonal. MANUEL D’INSTALLATION KIT DE CAPTEUR DE PRESSION Pour le personnel agréé uniquement. MANUAL DE INSTALACIÓN KIT DE SENSORES DE PRESIÓN Únicamente para personal de servicio autorizado. MANUALE DI INSTALLAZIONE KIT SENSORI DI PRESSIONE UTY-SPWX...
  • Page 2: Table Of Contents

    INSTALLATION MANUAL This mark indicates procedures which, if improperly CAUTION performed, might possibly result in personal harm PART NO. 9374707218-02 to the user or damage to property. PRESSURE SENSOR KIT Pay abundant care when transporting this product because it is a preci- Contents sion device.
  • Page 3: About This Product

    98 (3-7/8) sure in the refrigeration cycle will be- come abnormally high and prevent the 117 (4-5/8) unit from exerting its full performance. All Fujitsu General products Apply nitrogen gas while brazing the are manufactured to metric Nitrogen gas pipes.
  • Page 4: Wiring

    CAUTION 45° or 45° or The refrigerant less less pressure sensor Do not bind transmission cable, remote controller cable and sensor cable always installing together with or parallel to the power supply cable of the indoor and the connecting part outdoor units.
  • Page 5: Unit Wiring

    7.2. Unit wiring 8.1. Connecting the cables 7.2.1 Cable stripping (1) Turn off the system con- (2) Open nected to this product. Remote controller cable ( 2-wire) (2) Insert a screwdriver, etc., The remote controller cable length between this product and the indoor into the hole and open unit should be 10 m (32 ft) or less.
  • Page 6: Connecting The Cable To The Indoor Unit

    (b) When connecting to the exclusive terminal block 9. CONNECTING THE CABLE TO THE IN- Connect the end of remote controller cable directly to the exclusive terminal DOOR UNIT block. If there is the 2WIRE/3WIRE switch on the PC board of the indoor unit, set it CAUTION to match the connection method of the connected remote controller cable.
  • Page 7: 11. Turning On The Power

    11. TURNING ON THE POWER (1) Check this product wiring and setting of the switches on the circuit board. (2) Check the wiring and setting of the switches for the VRF system. For the wiring and switch settings method, refer to the installation instruc- tion sheet of each unit.