VEVOR 2402-UV18 Original Instruction
VEVOR 2402-UV18 Original Instruction

VEVOR 2402-UV18 Original Instruction

Hvac air purifier

Advertisement

Technical Support and E-Warranty Certificate www.vevor.com/support
HVAC AIR PURIFIER
MODEL:2402-UV18/2402-UV25
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only
represents an estimate of savings you might benefit from buying certain tools
with us compared to the major top brands and does not necessarily mean to cover
all categories of tools offered by us. You are kindly reminded to verify carefully
when you are placing an order with us if you are actually Saving
Half in comparison with the top major brands.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2402-UV18 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VEVOR 2402-UV18

  • Page 1 Technical Support and E-Warranty Certificate www.vevor.com/support HVAC AIR PURIFIER MODEL:2402-UV18/2402-UV25 We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us.
  • Page 2 This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS 1.Please read and understand this manual carefully before using the HVAC Air Purifier . 2.The installation should be done by an adult, and children should not use it without supervision. 3.UV lights are harmful to exposed skin and eyes, causing temporary or permanent blindness.
  • Page 4: Parameter List

    List of kit parts Magnetic UV tube*1pc bracket*1pc UV Unit *1pc M5*12 M5 nut*2pcs ST4*25 screw *4pcs bolt*2pcs PARAMETER LIST 2402-UV18 2402-UV25 Model Power Lights tube length 356mm 436mm Light wavelength 254nm 254nm UV lifetime 8000hours 8000hours Assembly lamp tube...
  • Page 5: Product Size

    Product size 2402-UV18 2402-UV25 Model 435mm 515mm About 345mm About 425mm 80mm 80mm 50mm 50mm Note:Please note whether the interior space of the HVAC pipe can accommodate the product.
  • Page 6: Installation Instructions

    Installation Instructions Selecting Mounting Location 1.The unit can be mounted in any orientation, but cannot be installed where people can see the UV lights. 2. Choose a location that will make changing/cleaning of the UV bulb(s) easy. 3. Install unit on a flat surface of the duct work ABOVE the air conditioning cooling coil (“A Coil”) if your HVAC system has air conditioning.
  • Page 7: Installation Steps

    Installation steps 1 . Pass the power cord through the circular hole of the magnetic bracket and connect the coupler of the power cord to the lamp base. 2 . Attach the lamp tube to the magnetic holder with two M5 bolts and nuts.
  • Page 8 3. Product fixed: A. The machine holds the inner wall of the pipe to be installed through a magnet B. The product can install the bracket in the pipe through two screws. C. Products can also be installed from the outside to the pipeline; First cut an installation hole according to the picture, put the product into the pipe, The two screw holes of the magnetic support shall be aligned with the two 3mm drilled screw holes,need to reserve a position of a power cord,...
  • Page 9 and then fix the product on the pipe with screws. After the installation, it is necessary to close the excess incision with aluminum foil tape or other insulation material to avoid UV light exposure and cause damage to people. Open hole size diagram Schematic diagram of installation...
  • Page 10 4.The ballast can be secured to the pipe wall by two screws. Bulb Cleaning and Replacement 1. Disconnect the power to the HVAC system, unplug unit, and allow UV bulb(s) to cool for at least 15 minutes before attempting to remove the unit. 2.
  • Page 11 4. Re-install the unit into the duct work and re-install the 2 screws. Tighten the screws evenly until unit is securely in place. DO NOT OVERTIGHTEN SCREWS. 5. Reconnect the power to the HVAC system and plug the unit back into a grounded power outlet.
  • Page 12 Technical Support and E-Warranty Certificate www.vevor.com/support...

This manual is also suitable for:

2402-uv25

Table of Contents