Download Print this page
Haier 1U25S2SM1FA Installation Manual
Hide thumbs Also See for 1U25S2SM1FA:

Advertisement

Quick Links

Please read this manual carefully before installation.
This appliance is filled with R32.
Keep this operation manual for future reference.
Manufactured: Qingdao Haier Air Conditioner General Co, Ltd.
ROOM AIR CONDITIONER
INSTALLATION MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1U25S2SM1FA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Haier 1U25S2SM1FA

  • Page 1 ROOM AIR CONDITIONER INSTALLATION MANUAL Please read this manual carefully before installation. This appliance is filled with R32. Keep this operation manual for future reference. Manufactured: Qingdao Haier Air Conditioner General Co, Ltd.
  • Page 3 Warning ..........................1 Indoor/Outdoor Unit Installation Drawings.................. 12 Safety Precautions ........................13 Read Before Installation ......................17 Installation Procedure.......................20 Outdoor Unit Troubleshooting....................25...
  • Page 5: Disposal Requirements

    CAUTION Do not install the air conditioner at any place where there is danger of flammable gas leakage. In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. Tighten the flare nut according to the specified method such as with a torque wrench.If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
  • Page 6: Installation Instructions

    Loading and Unloading/Transporting Management/Storage Requirements The products shall be carefully handled during loading and unloading. Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not allowed. The workers engaged in loading and unloading must be subject to necessary trainings on the potential hazards caused by barbarous handling.
  • Page 23 Air outlet Wind direction Cushion rubber 4.Installation dimension(Unit:mm) Power Wiring Terminal Power Wiring Distribution Hole The values of The installation dimension are shown in table 3...
  • Page 24: Connection Of Pipes

    The values of The piping size are shown in table 4 Connection of pipes To bend a pi pe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side rst makes working easier.
  • Page 27 table6 ceramic type of T 25A/250V. The explosion-proof breaker of the air conditioner should be all-pole switch. The distance between its two contacts should not be no A explosion-proof breaker must be installed.
  • Page 28 Haier...
  • Page 29 Appendix English Español Italiano Français Deutsch Português Appendix Apéndice Appendice Apéndice Blinddarm Apêndice Tabelle 1 - Die Werte Tabela 1 - Os valores table 1-The values of tabla 1-Los valores de tabella 1-I valori di co2 tableau 1-Les valeurs des CO2-Äquivalents de equivalente de CO2 co2 equivalent (t) co2 equivalente (t)
  • Page 30 Appendix Polski Türkiye Hrvatski Nederlands dodatek dodatak Bijlage tabela 1 - Warto ci tablo 1-CO2 e de eri tablica 1-Vrijednosti tabel 1-De waarden ekwiwalentu CO2 (t) de erleri (t) CO2 (t) co2 ekvivalenta (t) van co2-equivalent (t) 2 (t) Model Model Model Model...
  • Page 31 1U20YEEFRA 1U25YEEFRA 543.8 440 120/140 1U25YEMFRA 1U35YEMFRA 1U25YEFFRA-C 1U35YEFFRA-C 1U42S2SM1FA 1U50MEGFRA 1U35MEEFRA 1U50MEEFRA 1U50MEMFRA 1U50MEMFRA-C 1U25JEJFRA 1U25MECFRA-3 510 130/160 1U35JEJFRA 1U35MECFRA-3 1U25S2SM1FA 1U25S2SM1FA-NR 1U35S2SM1FA 1U35S2SM1FA-NR 1U50S2SJ2FA 1U50S2SJ2FA-NR 114.2 1U50JECFRA-3 1U68REEFRA 1U68REMFRA 1U68RENFRA 1U50REJFRA 355.5 1U68RENFRA-C 1U25BEEFRA table4-piping size 1U25S2SM1FA 1U35MEEFRA...
  • Page 32 Switch Leak Model size(minimu protector rated breaker(A) breaker(A) current(mA) m mm²) capacity (A) 1U20YEEFRA 1U25BEEFRA 1U25JEJFRA 1U25MECFRA-3 1U25S2SM1FA 1U25S2SM1FA-NR 1U25YEEFRA 1U25YEFFRA-C 1U25YEGFRA 1U25YEMFRA 1U35JEJFRA 1U35MECFRA-3 1U35MEEFRA 1U35S2SM1FA 1U35YEGFRA 1U35S2SM1FA-NR 1U35YEMFRA 1U35YEFFRA-C 1U42S2SM1FA 1U50MEEFRA 1U50JECFRA-3 1U50MEGFRA 1U50MEMFRA-C 1U50MEMFRA 1U50S2SJ2FA-NR 1U50REJFRA 1U50S2SJ2FA...
  • Page 33 Appendix Figure 1 1U25S2SM1FA 1U50MEMFRA 1U25YEMFRA 1U35S2SM1FA 1U25BEEFRA 1U35YEMFRA 1U42S2SM1FA 1U25S2SM1FA-NR 1U25JEJFRA 1U25YEGFRA 1U35S2SM1FA-NR 1U35JEJFRA 1U35YEGFRA 1U25YEFFRA-C 1U50REJFRA 1U50MEGFRA 1U35YEFFRA-C 1U20YEEFRA 1U50MEMFRA-C 1U25YEEFRA 1U25MECFRA-3 1U35MEEFRA 1U35MECFRA-3 1U50MEEFRA 1U50JECFRA-3 Outdoor unit Outdoor unit To Indoor unit To Indoor unit POWER 1U50S2SJ2FA...