Dear Customer! We wish to thank you for choosing the UNGARO product! Our pellet stoves represent continuous innovation in biomass heating. From design to production, every step of the manufacturing process is carried out entirely at our premises, including rigorous testing aimed at assessing and certifying the reliability and sustainability of each model, according to the most stringent European standards regulating emissions and safety.
(Bory model) This symbol is used to highlight in- Ungaro stoves has one or two fans for bet- formation which is important for The Ungaro’s stoves efficiency may vary ter distribution of hot air.
liability; • Do not wash the appliance with water. The appliance must be connected to • Check the chimney for obstructions The water could get inside the unit an electrical system which is equip- before lighting the appliance; and damage the electrical insulation ped with an earth conductor, as laid •...
200 mm lity of the installer. The technical documentation includes: 500 mm 200 mm Ungaro S.r.l. will not be held responsible for 2000 mm 1500 mm • Reference to the current standards; damage to persons or things in the event •...
Page 6
- c = 1300 mm 3.5 Flue gasses discharge Ungaro S.r.l. will not accept any liability in case of fire for failure to comply with the safety clearance. To discharge the flue gas outside, make a hole of an adequate size to the flue pipe.
INSTALLATION AND OPERATION MANUAL placed at the bottom of the vertical section 3.6 Air intake Clearance Symbol Description (mm) of the chimney. (mm) For proper functioning, the appliance should Height Existing flue (fig. 6) be positioned in a location where it is able X ≤...
4. Display • The combustion chamber and the (fig. 8) burning pot are clean; • The tecnical door and the glass door Led Chrono / Ignition Resistance / are closed; Auger / Fan blown hot air • The ash pan and the inspection box are closed;...
INSTALLATION AND OPERATION MANUAL 5.5 Ignition To start the stove, hold the button 3 for few seconds. At he beginning of the ignition the display shows “Ignite” and the led ON/ OFF blinks. An eventual anomaly during this phase will be shown on the display with a relative code (see chap.
The stove performs electronic cleaning of 5.11 Modulation Do not disconnect power supply until the burning pot. On the display appears the stove is completely cooled down. “Burner Cleaning”. As the room temperature nears its set point the stove calorific power automatically goes to the minimum.
Page 11
INSTALLATION AND OPERATION MANUAL Level 1 Level 2 Level 3 Value M1 - Set Clock 01- Day of week L-M-M-G-V-S-D 02- Hour 0-23 03 - Minute 0-59 04 - Day 1-31 05 - Month 1-12 06 - Year 00-99 M2 - Set Chrono M2-1 - Enable chrono 01 - Enable Chrono on/off...
M5– Buzzer 01– Buzzer On/off M6 - First Feeding 01 - First Feeding 90” M7 - Stove State 01 - Auger State info 02 - T minutes info 03 - Thermostat info 04 - Exhaust gasses info 05 - Exhaust Fan speed RPM info M8 - Calibration 01 - Access...
Page 15
INSTALLATION AND OPERATION MANUAL It’s possible to set two time slots, the first of hour is set OFF, the clock will ignore the comand. The following tables explain with the “START1 Day” and “STOP1 Menu Select Action Setting weekly program function. To confirm and to Day”, the second with START2 Day and go to the next function push the button 3.
Page 16
PROGRAM 2 PROGRAM 3 PROGRAM 4 Menu Select Action Setting Menu Select Action Setting Menu Select Action Setting START Activation START Activation START Activation M2-3-20 M2-3-29 M2-3-11 PRG 2 Hour 0-23:50 PRG 3 Hour 0-23:50 PRG 4 Hour 0-23:50 STOP Disactivation STOP Disactivation...
Page 17
INSTALLATION AND OPERATION MANUAL 4 - Week end Program 6.3 Menu M3 - Choose Language State Meaning 3,1” Auger State The menu enables/disables and sets week To set display language, select menu M3 end chronothermostat function (days 6 52’ Time out with the button 3, choose language with and 7).
7. Alarms 7.3 Exhaust Over-temperature Alarm turns off. If the exhaust probe detects overtempera- ture, on the display appears “Al 3 alar al 3 If a fault occurs on the stove, an error code Hot Fumes” and the stove turns off. will be shown on the display with an alarm led and acoustic signal on.
INSTALLATION AND OPERATION MANUAL 7.9 Troubleshooting ve re-starts normal work. Please remember that manual burner cleaning is absolutely necessary before each ignition. Error Cause Solution Faulty stove and flue pipe mainte- Power supply interrup- Al 1 Alar al 1 nance can alternate proper functio- ted in phase of opera- Empty the burner pot and re-start the stove Blac-out...
Page 20
fig. 17 - Ash box TAF fig. 13 - Burning pot TAF fig. 15 - Burning pot Bory 8.3 Ash Box Cleaning Empty the ash box when it is full or each 15 days. Carefully replace the box (fig. 16,17,18,19) and fix with the screws. fig.
Page 21
INSTALLATION AND OPERATION MANUAL fig. 19 - Gally Ash collectors 8.4 Inspection Cleaning Clean the inspection compartment when it is full or each 20 days. Remove the lid, empty the inspection with an ash vacuum (fig. 20, 21, 22, 23), close the lid. fig.
cleaned each 10/20 refills, depends on the quantity of dust in the pellets. Faulty hop- per cleaning can void the warranty, with the manufacturer declining all related liability. 8.7 Annual service Annually contact the local Technical Support to perform annual service: •...
2. Invoice for the used spare parts for out of warranty interventions. Bory Model UC10 pellet logs Ungaro S.r.l. reminds that the Heat manufacturer is the holder of Input the rights provided by Leg. D. 02/06/2002 and the guarantee does not affect these rights.
12. Technical Drawings Ø60 Ductable Ø80 Posterior Ø60 uscita aria Ø80 Uscita fumi Hot Air Smoke Exhaust canalizzata posteriore Ø80 Smoke Exhaust Ø80 Uscita fumi top view front view back view side view ORCHIDEA (TF9-TF12) All dimensions are in millimeters...
Page 27
INSTALLATION AND OPERATION MANUAL Ø60 Ductable Ø60 Uscita aria Ø80 Posterior Hot Air Ø80 Uscita fumi canalizzata Smoke Exhaust posteriore Ø80 Smoke Exhaust Ø80 Uscita fumi back view top view front view side view MARIQUITA (TF9-TF12) All dimensions are in millimeters...
Page 28
Ø80 Smoke Exhaust Ø80 uscita fumi top view front view side view LA TONDA (TF9) All dimensions are in millimeters...
Page 29
INSTALLATION AND OPERATION MANUAL Ø80 Smoke Exhaust Ø80 uscita fumi 599,5 back view top view front view FAGIOLO ARIA (TF9-TF12) All dimensions are in millimeters...
Page 30
Smoke Exhaust Ø 80 Smoke Exhaust Ø 80 Primary Air Ø 50 Ductable Hot Air Ø 60 back view front view top view side view ZEFY (TF9-TF12) All dimensions are in millimeters...
Page 31
INSTALLATION AND OPERATION MANUAL Smoke Exhaust Ø 80 Smoke Exhaust Ø 80 back view front view top view side view OSTRY (TF9-TF12) All dimensions are in millimeters...
Page 32
Smoke Exhaust Ø 80 Primary Air Ø 50 Smoke Exhaust Ø 80 Forced Hot Air Ductable Hot Air Ø 60 back view top view front view side view LIBY (AR7) All dimensions are in millimeters...
Page 33
INSTALLATION AND OPERATION MANUAL Smoke Exhaust Ø 80 Smoke Exhaust Ø 80 Primary Ø 50 Ductable Hot Air Ø 60 front view back view top view side view SOLE (AR7) All dimensions are in millimeters...
Page 34
Ductable Hot Air Ø 60 Smoke Exhaust Ø 80 top view front view side view back view FOGLIA (AR7) All dimensions are in millimeters...
Page 35
INSTALLATION AND OPERATION MANUAL front view Smoke Exhaust Ø 80 Primary Air Ø 50 back view top view side view GALLY (UC10) All dimensions are in millimeters...
Page 36
Smoke Exhauste Ø 150 Uscita fumi Ø 150 Air Inlet Ø 50 Entrata aria Ø 50 Entrata Air Inlet Ø 50 Aria convettiva Ductable hot air Ø aria Ø 50 canalizabile Ø 60 front view back view top view side view BORY All dimensions are in millimeters...
Page 37
INSTALLATION AND OPERATION MANUAL 304,5 335,5 Ø100 1019 Air Inlet Ø 50 Ø50 front view 104,5 303,6 89,4 back view top view side view V Serie All dimensions are in millimeters...
Page 38
The Customer is in charge of eventual costs (re- The warranty is valid under conditions: pair, transport) arising from improper exercise of This is the only guarantee Ungaro S.r.l. gives for warranty rights. the product. No one else may give any guarantee, •...
Page 39
Ungaro S.r.l. - Via S. Mango 2 - 88040 S. Mango D’Aquino - CZ. Providing my personal data is voluntary: in the lack of them Ungaro S.r.l. cannot provide services mentioned above.
Page 40
Under no circumstances shall Ungaro S.r.l assume liability for imprecise contents or eventual errors in this manual. In order to improve the product, to keep this publication up to date the Ungaro S.r.l reserves the right to make modifications without any advance notice.
Need help?
Do you have a question about the V Series and is the answer not in the manual?
Questions and answers