Summary of Contents for UNGARO FAGIOLO PLUS

  • Page 1 PLUS INSTALLATION AND OPERATION MANUAL...
  • Page 2: Table Of Contents

    Dear Customer! We wish to thank you for choosing the UNGARO product! Our pellet stoves represent continuous innovation in biomass heating. From design to production, every step of the manufacturing process is carried out entirely at our premises, including rigorous testing aimed at assessing and certifying the reliability and sustainability of each model, according to the most stringent European standards regulating emissions and safety.
  • Page 3: Product Description

    • EN 14785 • Incorrect installation or faulty maintenan- The Ungaro stove is a heat generator for • EN 13240 ce (not conforming to the requirements domestic use running on wood pellet, in- •...
  • Page 4: Installation

    2.2 Operating Warnings lity of the installer. mage the electrical insulation and cause Ungaro S.r.l. will not be held responsible for electric shocks; • During the first operating cycles, regularly damage to persons or things in the event •...
  • Page 5 100 mm round; fig.3. Then must the ductable ait function • It must be resistant to heat, mechani- Ungaro S.r.l. will not accept any must be activated in the control panel. This cal stress, heat, combustion residues liability in case of fire for failure to modification can be made only by an au- and related condensate;...
  • Page 6 caldoungaro.it Pa (UNI 10683). Flue gasses discharge on the wall is In the case of the flues close to each other, not permitted by current regulations. refer to fig.5 e tab.1. Failure to comply can lead to the ter- The proper draught conditions in the mination of the guarantee and of the flue is critical for the efficient wor- manufacturer’s responsibility for the...
  • Page 7 INSTALLATION AND OPERATION MANUAL Outdoor Chimney (fig. 6) Existing flue (fig. 7) 3.6 Air intake For proper functioning, the appliance should Insulated Insulated Chimney Chimney be positioned in a location where it is able Outdoor Outdoor Cowl Cowl Section to take in the air necessary for combustion. Section Provide an air intake hole Ø100 mm²...
  • Page 8: Display

    caldoungaro.it 4.2 Messages entry of foreign bodies and animals. In case Button Description Function of air intake from adjacent non-external Exit from menu environment, the duct connected to the Message Description submenu generator must terminate in the first room ON / OFF, different from the room of installation.
  • Page 9 INSTALLATION AND OPERATION MANUAL 4.3 User Menu N 1 User Menu N 1 In this menu can be modified the combustion power. The menu can be seen only if in the menu “Service” the submenu “Automatic power” is set to “OFF”. In the menu “Combustion” if set to “Auto” (recommended) it balan- ces the combustion power to the difference between the settings of the “Room thermostat”...
  • Page 10 caldoungaro.it Three types of programming are available: Daily, Weekly, Week-end. After having chosen the Monday program: • with the arrow buttons 6 or 4 select the time slot to program 09:30 11:15 √ • enter in modification mode by pressing the button 3 (the time slot starts to blink) Chrono Program 00:00...
  • Page 11 Ungaro S.r.l. recommends to modify this para- meter only if indicated by an authorised technician and however varying one step at a time and eventually repeating if necessary.
  • Page 12: Operation

    OFF when this option must be enabled. After the loading has stopped, clean the burn pot with ash vacuum cleaner before starting the ignition. Service Test Loading This menu is for the exclusive access of Ungaro Technical Support List nodes This menu is for the exclusive access of Ungaro Technical Support Contrasto...
  • Page 13 INSTALLATION AND OPERATION MANUAL phase, on the display will appear “Igni- room temperature. If the fan power is set It is recommended to set “Auto” in tion” (“PA1”). The pellet starts falling in “Auto, the fan will be autoamtically syncro- the menu “Power”...
  • Page 14: Maintenance

    caldoungaro.it 6. Maintenance the lid pushing down the handle. To ensu- re proper combustion, close tightly the in- spection compartment. To ensure smooth operation and maintain high performance, clean the stove regu- larly. The frequency of cleaning is determi- ned by the length of time the appliance has been running and by the type of pellet.
  • Page 15: Notifications And Alarms

    INSTALLATION AND OPERATION MANUAL conds the button SET. per cleaning can void the warranty, with the manufacturer declining all related liability. 7.1 Service 6.4 Annual service When on the display appears “Service”, Annually contact the local Technical Support clean carefully the stove and the pellet tank for service and check up of the following (see chap.
  • Page 16 caldoungaro.it 7.3 Troubleshooting Error Description Solution Let the stove cool and check the pellet tank. Check if the space where the stove is installed is correctly ventila- Overheated pellet hopper ted. Disarm the thermal security thermostat, it can be found below the power cable. Unscrew the black cap that Er01 covers a white button, press the button until hearing a click.
  • Page 17: Motherboard

    INSTALLATION AND OPERATION MANUAL 8. Motherboard 9. After Sale Service For any information or problem please contact your Seller. Line (250V - 50Hz) Burner Cleaner 9.1 Technical intervention Switch Room Combustion thermostat Please read this manual carefully before contacting technical support. The customer support will ask the following data: Ductable Air 1.
  • Page 18: Technical Data

    93,1 92,8 out of warranty interventions. P.max kg/h Consumption P.min kg/h Ungaro S.r.l. reminds that the manufacturer is the holder of Pellet tank the rights provided by Leg. D. 02/06/2002 and the guarantee Flue pipe does not affect these rights.
  • Page 19: Technical Drawings

    INSTALLATION AND OPERATION MANUAL 11. Technical Drawnings FAGIOLO PLUS 6/9/12 602,5 ZEFY PLUS 6/9/12 15,6 212,5...
  • Page 20 The Customer is in charge of eventual costs (re- rized personnel. pair, transport) arising from improper exercise of This is the only guarantee Ungaro S.r.l. gives for the product. No one else may give any guarantee, warranty rights. The warranty is valid under conditions: warranty, or condition on Ungaro’s behalf.
  • Page 21 Ungaro S.r.l. - Via S. Mango 2 - 88040 S. Mango D’Aquino - CZ. Providing my personal data is voluntary: in the lack of them Ungaro S.r.l. cannot provide services mentioned above.
  • Page 22 Under no circumstances shall Ungaro S.r.l assume liability for imprecise contents or eventual errors in this manual. In order to improve the product, to keep this publication up to date the Ungaro S.r.l reserves the right to make modifications without any advance notice.

This manual is also suitable for:

Zefy plusV special plus

Table of Contents