  • Page 2: Table Of Contents

    Replacement Parts 16-17 Harness EUR402M Schematics - Water and Introduction The EUR402 and EUR412 unit is a shelf cooler which includes an option of a cold carbonation incorporating soda recirculation system. This self contained, compact unit has serviceability at the forefront of design.
  • Page 3: Removal, Transport & Disposal

    It is illegal to simply scrap a refrigeration unit. Before a unit can be scrapped it must first have the gas removed by a specialist using specialist equipment. Please contact Booth Dispensers Ltd, who will be happy to provide a quotation for disposal.
  • Page 4: Specifications

    Specifications EUR402M Dimensions 300mm (H) NUY45RAa 600mm (W) Compressor 4.5cc 400mm (D) Dry Weight 34Kg This product contains Propane Refrigerant gas with a GWP of 3 in a hermetically sealed system. Wet Weight 50Kg Supply 230V/AC - 50Hz Refrigerant R290, 80g...
  • Page 5: Installation And Commissioning

    Installation and Commissioning Installation and Commissioning • The unit must be installed by a competent person, on a firm level surface capable of supporting the weight of the machine when the bath is filled, and all connections made. Please ensure that the unit is positioned at least 100mm from any other surfaces, as it is important that the ventilation openings in the machine are not blocked and allow the free movement of air for both the carbonator &...
  • Page 6 1ltr – 2litres of carbonated water per dispense point to allow for full circulation around the system. • Product lines can be connected as intended dependant on demand of the unit, ensure that syrup coils not in use are capped off so no debris may accumulate. EUR402M EUR412M...
  • Page 7: Eur402M Schematics - Wiring

    EUR402M Schematics - Wiring Harness...
  • Page 8: Eur402M Schematics - Water And

    EUR402M Schematics - Water and Gas...
  • Page 9: Eur412M Schematics - Wiring Harness

    EUR412M Schematics - Wiring Harness...
  • Page 10: Soda

    EUR412M Schematics - Water & Soda...
  • Page 11: Fault Finding

    Fault Finding Prior to any fault finding, please ensure all water and gas connections to the chiller are sound and that the incoming water and gas supplies are turned on. Also ensure that all electrical connections to the chiller and in the chiller are secure and in good condition, the power is on.
  • Page 12 Fault Finding CO2 pressure (check by Check CO2 bottle, regulator and non-re- turn valve. Supply pressure should be 55 operating pressure relief psi, adjust or replace as necessary. valve on carbonation can) Check carbonation probe for possible short circuit to ground. Including moisture No Carbonated on the can lid.
  • Page 13: Cleaning

    Fault Finding Possible overheat. Allow unit to cool. The Compressor not compressor will start once the unit has cooled running sufficiently. If the problem persists investigate possible causes. Check that the condenser is not blocked. Insufficiant air flow Warm Drinks Check that the air filter is not blocked.
  • Page 14 Cleaning Prepare the Unit Disconnect the electrical power to the unit and isolate from the water supply. Carefully following the manufacturer’s instructions, prepare a solution of proprietary sanitizing fluid. Sanitize the Water System Disconnect flexible water inlet tube from the water supply and place the end into a container of sanitizing fluid.
  • Page 15 Cleaning Deep Clean - Parts in contact with food products. Important: It is recommended that the deep clean procedure be per- formed at least monthly. Remove dispense components, pre clean using a damp multi-purpose disposable cleaning cloth soaked in warm water. Soak cloth in cleaning agent solution, remove excess water and clean dispense components.
  • Page 16: Replacement Parts

    Replacement Parts Part Image Part No. Part Description 1B7102 1/2” - 3/8” Reducer 1B3961 1/2” Bulkhead 1B5604 3/8”” - 3/8” Stem Elbow 1B8108 5/16” - 3/8” Stem Elbow 1B4080 3/8” Bulkhead 1B7278 5/16” - 3/8” Reducing Elbow 1B3656 3/8” Equal Elbow 1B3824 3/8”...
  • Page 17 Replacement Parts Part Image Part No. Part Description 4A0012 Agitator Assembly 4A0002 Can Fill Pump Assembly 1A5417 4A0022 Recirculation Pump Assembly 4B0179 Fan Assembly...
  • Page 18 Notes...
  • Page 19 Notes...
  • Page 20 Booth Dispensers Limited, 101 Moor Park Avenue, Blackpool, Lancashire, FY2 0LZ, UK. +44 1253 501800 Website: www.booth-dispensers.co.uk/...

This manual is also suitable for:

Eur412m

Table of Contents