dol sensors iDOL 139 LoRa Technical User Manual

Co2, humidity and temperature sensor

Advertisement

Technical User Guide
iDOL 139 LoRa
CO2, Humidity and
Temperature Sensor
dol-sensors a/s
– Agro Food Park 15
– DK-8200 Aarhus N
– T: +45 7217 5888
– F: +45 7217 5959
– www.dol-sensors.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iDOL 139 LoRa and is the answer not in the manual?

Questions and answers

Summary of Contents for dol sensors iDOL 139 LoRa

  • Page 1 Technical User Guide iDOL 139 LoRa CO2, Humidity and Temperature Sensor dol-sensors a/s – Agro Food Park 15 – DK-8200 Aarhus N – T: +45 7217 5888 – F: +45 7217 5959 – www.dol-sensors.com...
  • Page 2: Product Description

    4 pcs. standard M12 male with 5 pins. Supplied with 2 m cable with plug. 140355 iDOL 64 Gateway modem wireless Receives wireless, LoRa-based sensor data and forwards it to the dol-sen- sor cloud service. Supplied with 2 m cable with plug. www.dol-sensors.com iDOL 139 LoRa...
  • Page 3: Spare Parts

    140261 DOL 119/139 Protection cap plug 5 pcs. Protection cap for DOL 119/139 for protection of the sensor during, for ex- ample, cleaning. 140269 Cable 2 m M12 plug incl. sealing plug 2 meter cable with M12 plug and sealing plug. www.dol-sensors.com iDOL 139 LoRa...
  • Page 4: Led Indication

    Sensor status on LED. State Description Green ON The sensor is connected to gateway and operation ok. Green flash The sensor is attempting to connect to the gateway. Red ON Sensor fault. Red flash Measurement outside the specified range. www.dol-sensors.com iDOL 139 LoRa...
  • Page 5: Maintenance

    It must be possible for customers to deliver the products to local collection sites/recycling stations in accor- dance with local instructions. The recycling station will then arrange for further transport to a certified plant for reuse, recovery and recycling. www.dol-sensors.com iDOL 139 LoRa...
  • Page 6: Technical Data

    Technical User Guide 6 Technical data iDOL 139 LoRa Specification Parameter Unit LoRa modul LoRaWAN version 1.0.2 Regional parameters version Revision B Radio frequency plan Europe – 863-870 Spreading factor 7–12 (Depends on noise and obstacles) Transmission frequency 1 (SF 7)
  • Page 7: Connection Terminal

    Technical User Guide 6.1 Connection terminal Pin connection in Digital signal Color M12 plug (sensor output) 24 V Brown Pin 1 Reserved White Pin 2 Reserved Black Pin 4 Blue Pin 3 6.2 Dimensions Dimensions in mm. www.dol-sensors.com iDOL 139 LoRa...
  • Page 8 Technical User Guide dol-sensors a/s – Agro Food Park 15 – DK-8200 Aarhus N – T: +45 7217 5888 – F: +45 7217 5959 – www.dol-sensors.com...

This manual is also suitable for:

140356

Table of Contents