  • Page 1 RLT-24 Veterinary Laser Therapy User Manual...
  • Page 2: Intellectual Property

    RWD reserves the right to keep this User Manual as confidential information. No individual or organization may disclose all or part of the User Manual by any means without the written permission of RWD, nor should it allow others or organizations to obtain all or part of the User Manual by any means.
  • Page 3: Table Of Contents

    Contents 1-Introduction....................... 1 1.1 Overview .......................... 1 1.2 Safety ..........................1 1.3 Product introduction ....................... 1 1.4 Product features ......................2 1.5 Product parameters ......................2 1.6 Product list ........................3 1.7 Device environmental requirements ................3 2- Important information and safety ..............4 2.1 Product identification and safety symbols ..............
  • Page 4 7-Maintenance ....................25 7.1 Overview ........................25 7.2 Daily maintenance ......................25 7.3 Routine inspection on device ..................25 7.4 Annual inspection ......................26 8-Waste disposal ....................26 9-Electromagnetic compatibility ................27 9.1 Radio-frequency (RF) emission ..................27 9.2 Electromagnetic immunity .................... 28 10-Product warranty ....................
  • Page 5: 1-Introduction

    1-Introduction 1.1 Overview First of all, thank you for choosing RWD RLT-24 Veterinary Laser Therapy! Before the installation and application of this product for the first time, please read all attached materials to help you use this product in a better way.
  • Page 6: Product Features

    1.4 Product features  Intelligence solution: more than 1,300 recommended treatment built in, featured by easy operation and easy control by veterinarians;  Multiple modes: support three laser emission modes: CW mode, Pulse mode and ISP mode. The combination of multiple modes can improve the treatment efficiency, reduce thermal burns, and intensify laser treatment;...
  • Page 7: Product List

    1.6 Product list Configuration Name Quantity Description Veterinary Laser Standard configuration Laser therapy Therapy Standard configuration Optical fibre handpiece 1 Laser transmission and control Change the beam size to realize optimal Standard configuration Lens treatment and diversity 3 for staff and 3 for animals for eyes Standard configuration Protective goggles protection...
  • Page 8: 2- Important Information And Safety

    2- Important information and safety 2.1 Product identification and safety symbols The identifications and safety symbols of the Veterinary Laser Therapy are as follows. If you have any questions or suggestions on safety, please contact us for after-sales service support. Symbol Description Safety warning: laser hazard;...
  • Page 9: Safety Precautions

    5) If the device fails to work properly, please contact the after-sales personnel of RWD immediately. Do not open the shell of the device without authorization. Unauthorized disassembly of the device may result in electric shock, serious personal injury or device damage.
  • Page 10: Therapy Room Safety

    3) All personnel and animals on the site must wear protective goggles specified by RWD during the operation of the Veterinary Laser Therapy. Protective goggles other than those specified may cause injury to eyes.
  • Page 11: Safety Classification

    8) Please power off the device and disconnect the cable to keep the device properly when the device is not in use or there is no person on the site. 9) The device is provided with a four-digit login password (see the user manual), which can be customized by users and can only be saved by designated and authorized personnel.
  • Page 12: Safety Functions

    2.4 Safety functions Veterinary Laser Therapy have a series of safety monitoring and safety functions for monitoring the system operating status and the emergency stop of laser output. When using the device, users should know the funtion and operation of these safety configurations. Safety configuration Function and operation Power switch...
  • Page 13: 3- Product Structure And Interface Introduction

    3- Product structure and interface introduction Figure 3-1 Figure 3-2 Part name Function USB port Software update Finger switch During normal operation, start/pause laser emission Optical fibre handpiece Laser transmission and control Lens Change the size of the laser beam Laser aperture Connect optical fibre Finger switch interface...
  • Page 14: 4- Product Installation

    4- Product installation Before unpacking, please check the outer packaging carefully. For any damage or bumps found, please contact RWD as soon as possible. After confirmation, you can proceed to the next step; Take all items out of the shipping box and properly keep the original packaging for future transportation;...
  • Page 15  Optical fibre handpiece and lens connection Select the required lens and insert it into the bottom of the optical fibre handpiece.  Optical fibre and laser aperture connection The laser aperture is used to connect the optical fibre and is located on the rear panel of the device.
  • Page 16 Note: Do tighten it up!  Finger switch and finger switch interface connection Use the finger switch interface to connect the finger switch to the device. Align the red dot on the finger switch with that on the finger switch interface, and then insert it into the interface.
  • Page 17  Power adaptor connection This product has two power: external power adaptor and internal battery. When the internal battery is low, insert the power adaptor horizontally into the power interface. Internal battery: When users use the internal battery, the device can be started directly. When the battery capacity is below 20% and 5%, users will receive a prompt to connect the power adaptor.
  • Page 18: 5-Operation Instruction

    5-Operation Instruction 5.1 Initial start After device startup, the system first enters the enter password interface. The default password for the first boot is 0000. Please refer to 5.9 System settings for the password change. Figure 5-1 Enter the correct password to enter the main interface, as shown in Figure 5-2. Figure 5-2...
  • Page 19: Selection Of Treatment

    Button name/icon Description Feline. Click to enter the [Treatment selections]; the operation of other species of buttons: Canine, Equine, and exotic pets Click to enter [Custom treatment] for users to add custom treatment Click to enter [Patient List] Click to enter [Video Tutorial]. It includes many types of tutoring videos for users to learn and refer Click to enter [System Settings].
  • Page 20: Treatment Preparation

    Select [Musculoskeletal] and enter the interface as shown in Figure 5-4. Figure 5-4 Select [PostOp], then select Body Part, Coat Color, Chronicity, Weight and Treatment Area. After selecting all the steps for this species, users will finally enter the interface as shown in Figure 5-5.
  • Page 21 Parameter Description button can increase or decrease the power of all treatment phases for Avg Power current body part by 25% or 25%, and button can only be clicked twice in a row button can increase or decrease total time of all treatment phases for Total Time current body part by 25% or 25%, and button can only be clicked twice...
  • Page 22: Start Treatment

    Parameter Description Laser Mode CW mode, Pulse mode, ISP mode are available for one choice Click [Phase Time] to edit, and click [Store] / [Store to all Stages] to make the Phase Time Time applicable to all phases of the current body part. Time ranges from 00:00- (60: 00- total time of other phases) Click [Avg Power] to edit, with setting range between 0.5-24.0W (CW mode), Avg Power...
  • Page 23 Figure 5-8 Users select the corresponding lens in the interface as shown in Figure 5-8 according to the lens currently assembled on the device, and the following interface pops up. Warning: Be sure to wear protective goggles! Do not turn the laser emitting surface toward the eyes.
  • Page 24: Pause Treatment

    Figure 5-10 5.5 Pause treatment Users can click or press the finger switch to pause the current laser emission. The interface is shown in Figure 5-11. Figure 5-11 Users can click to continue treatment. 5.6 Complete treatment 1) When the current body part treating is finished, the laser emission is paused and the interface is as shown in Figure 5-13.
  • Page 25: Custom Treatment

    Figure 5-12 2) After the treatment of all the body parts is finished, the [Treatment Complete] as shown in Figure 5-13 will pop up, and users can click the button as needed. Figure 5-13 5.7 Custom treatment Users can click in Figure 5-2 to enter [Custom Treatment] to view the built-in treatment, as shown in Figure 5-14, and search, select, create, delete, edit, rename, and apply any custom treatment.
  • Page 26: Patient List

    Figure 5-14 When user's treatment is finished, the treatment can be saved to a new custom treatment or an existing custom treatment, as shown in Figure 5-13. 5.8 Patient list Users can click in Figure 5-2 to enter the [Patient List] as shown in Figure 5-15, and search, add, edit, delete and view any patient.
  • Page 27: System Settings

    Figure 5-16 After users’ treatment is finished, the treatment records can be saved as an existing patient or a new patient, as shown in Figure 5-13. 5.9 System settings Click to enter [System settings] as shown in Figure 5-17 Figure 5-17 Function item Description Brightness...
  • Page 28: 6- Alarm/Fault

    6- Alarm/Fault This product has a built-in monitoring system that monitors the laser temperature, emergency stop button, interlock, finger switch and optical fibre status in real time, and provides warnings through acoustic and optic graphic texts on the display to remind users that of such device abnormality or fault.
  • Page 29: 7-Maintenance

    Try to keep the device stable and prevent vibration or collision when moving it;  Do not disassemble the device without permission, and do not open the device shell without the authorization of RWD, otherwise it may cause electric shock or damage to the device; ...
  • Page 30: Annual Inspection

    7.4 Annual inspection RWD recommends an overall annual inspection of the device. Contact RWD for details. Annual inspection is helpful to keep the device in good working condition. It is recommended to record the maintenance process, including the maintenance time, location, and process for future reference.
  • Page 31: 9-Electromagnetic Compatibility

    Do not stack the laser therapy with other devices, otherwise it may interfere with the normal work of the device.  Users must use the accessories provided by RWD. Use of other accessories may lower the electromagnetic compatibility of the laser therapy. 9.1 Radio-frequency (RF) emission...
  • Page 32: Electromagnetic Immunity

    9.2 Electromagnetic immunity Immunity test GB9706 test level Compliance level Electrostatic discharge (ESD) EN 61000-4-2 ±8kV contact discharge ±8kV contact ±15kV air discharge discharge ±15kV air discharge Electrical fast transient burst EN 61000-4-4 ±2kV to power cord Applicable ±1kV to input/output line Surge EN 61000-4-5 ±1kV line to line Applicable...
  • Page 33: 10-Product Warranty

    In this case, expenses for maintenance or parts replacement will be borne by users. When the device to be reworked arrives, if it has been dismantled without authorization from RWD, RWD will not provide after-sales services such as warranty, free maintenance and parts replacement.
  • Page 34 RWD Life Science Co., Ltd. Web: www.rwdstco.com Add: 850 New Burton Road, Suite 201, Dover, DE 19904, Kent, Delaware, USA Add: 19/20F, Building 9A, Vanke Cloud City III, Liuxin 4 Street, Nanshan District, Shenzhen518000, Guangdong, P.R. China Tel: +001-858-900-6602 +86-755-86111286 After-sales Service: +86-755-86111281 After-sales E-mail: service@rwdstco.com...