Advertisement

Quick Links

Document No.: YF.SMS231201
Model: C411W
Version: A2
User Manual
C411W
LCD Monitor
Page 1 of 32
en-US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C411W and is the answer not in the manual?

Questions and answers

Summary of Contents for Beacon C411W

  • Page 1 Document No.: YF.SMS231201 Model: C411W Version: A2 User Manual C411W LCD Monitor Page 1 of 32 en-US...
  • Page 2: Change History

    Document No.: YF.SMS231201 Model: C411W Version: A2 Change History Version Date Author Modification 2024.01.29 Li Bo release. 2024.03.15 Li Bo Page 25, update user manual icon instructions. Add information and references to PIPS and Philips, add content on operational environment 2024.11.22...
  • Page 3: Table Of Contents

    Document No.: YF.SMS231201 Model: C411W Version: A2 Table of contents 1 Introduction ............................. 4 1.1 About the product .........................4 1.2 About the user manual .........................5 1.3 Packing list ........................... 5 2 Safety information ...........................7 3 Security Measures for the Operating Environment ................12 4 View and connectors ..........................
  • Page 4: Introduction

    Version: A2 1 Introduction 1.1 About the product C411W is a 27-inch TFT color medical display, with high resolution, high contrast, and specialized tuning, specially developed for pathological diagnosis, pathological research analysis, and pathological consultation. The product complies with DICOM 3.14 and sRGB color gamut standards, and undergoes professional calibration and inspection before leaving the factory.
  • Page 5: About The User Manual

    Please read these safety information and product information so that you can operate the machine safely and effectively. This user manual is only suitable for C411W. Please save this manual for future use.
  • Page 6 1 PCS For Philips, the one pager includes the link to download this manual the One Pager C411W LCD Monitor User manual, the QA Manager User manual and 1 PCS the actual QA Manager software. Note: Please keep the packing material for future transport.
  • Page 7: Safety Information

    Document No.: YF.SMS231201 Model: C411W Version: A2 2 Safety information This monitor is Class II equipment (Display with external power supply: Class II equipment), to ensure personal safety and proper maintenance, please read this section and the caution statements on the unit.
  • Page 8 Document No.: YF.SMS231201 Model: C411W Version: A2 FCC Statements This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: 1. this device may not cause harmful interference 2. this device must accept any interference received,including interference that may cause undesired operation.
  • Page 9 Document No.: YF.SMS231201 Model: C411W Version: A2 The equipment must be connected to a grounded main outlet. To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Handle the power cord with care.
  • Page 10 Document No.: YF.SMS231201 Model: C411W Version: A2 CAUTION Handle with care when carrying the unit. Disconnect the power cord and signal cables and remove the optional unit. Moving the unit with the cord or the option attached is dangerous. It may result in injury.
  • Page 11: Lcd Panel

    Document No.: YF.SMS231201 Model: C411W Version: A2 LCD PANEL When the monitor is cold and brought into a room or the room temperature goes up quickly, dew condensation may occur inside and outside the monitor. In that case, do not turn the monitor on and wait until dew condensation disappears, otherwise it may cause some damages to it.
  • Page 12: Security Measures For The Operating Environment

    Document No.: YF.SMS231201 Model: C411W Version: A2 3 Security Measures for the Operating Environment The following measures represent a non-exhaustive list of potential security controls to safeguard the operating environment. It is critical that the operating environment neither obstructs the application of these controls nor forces the product to operate at a reduced security level.
  • Page 13: View And Connectors

    Document No.: YF.SMS231201 Model: C411W Version: A2 4 View and connectors 4.1 Front view 4.2 Back view Page 13 of 32 View and connectors...
  • Page 14: Connector Pin Assignments

    Document No.: YF.SMS231201 Model: C411W Version: A2 4.3 Connector pin assignments 4.3.1 DVI-D Connector DL-DVI(Dual link) Signal Signal Signal TMDS Data 2- TMDS Data 1- TMDS Data 0- TMDS Data 2+ TMDS Data 1+ TMDS Data 0+ TMDS Data 2/4 Shield...
  • Page 15: Usb Upstream Port

    Document No.: YF.SMS231201 Model: C411W Version: A2 4.3.3 USB Upstream port USB Upstream port USB-Type B connector Signal 4.3.4 USB Downstream port USB-Type A connector, USB 2.0 compliant USB Downstream port USB-Type A connector, USB 2.0 compliant Signal Computer USB expansion interface, it can identify U disk, mouse, etc.
  • Page 16: Connection And Quick Start

    2. the packaging has not been exposed to environmental conditions outside of those specified in the chapter “Technical specification”. In case of doubts, please contact Beacon. To prevent damage of the product, do not use a knife to open the box.
  • Page 17: Quick Start

    Resolution: 2560 x 1440, Refreshing frequency: 60 Hz. If there is no image visible, please refer to the section “Troubleshooting” of this manual for help. 3. Make sure the monitor is calibrated, refer to the “Beacon QA manager User Manual”(Download URL: https://en.beacon-display.cn/manual).
  • Page 18: Keys Function And Menu

    Document No.: YF.SMS231201 Model: C411W Version: A2 6 Keys function and menu 6.1 Power indicator Color Display mode Green Operating mode Orange Standby mode None Power off mode 6.2 Keys function When OSD menu is closed: Keys Function OSD menu function key.When selecting Native mode in the color gamut, long press the shortcut menu status to switch between grayscale/color modes.
  • Page 19: Osd Menu

    Document No.: YF.SMS231201 Model: C411W Version: A2 6.3 OSD Menu All adjustments and settings for OSD menu are listed in the following table. Menu Function Option Description Color sRGB/Native Default sRGB. Gamut sRGB mode : 1.8/1.9/2.0/2.1/2.2/2.4/2.6/2.8/3.0/Standard Gamma Default 2.2. Native mode: 2.0/2.2/2.4/2.6/DICOM Switchable only under DICOM.
  • Page 20: Front Sensor Qa Function

    Note : The greyed out settings cannot be selected and have no functionality. 6.4 Front Sensor QA Function For the specific operation steps of this function, please refer to the “Beacon QA manager User Manual(Download URL: https://en.beacon-display.cn/manual)”. Page 20 of 32...
  • Page 21: Technical Specification

    Document No.: YF.SMS231201 Model: C411W Version: A2 7 Technical specification For Display performance testing information, please refer to Appendix A. Monitor characteristics : Screen technology 27”, TFT, color, LCD screen, AG type Active area(H x V) 596.74 x 335.66 mm Pixel pitch 0.2331 mm (H) x 0.2331 mm (V)
  • Page 22 Document No.: YF.SMS231201 Model: C411W Version: A2 Mechanical characteristics : Housing components Plastic Ventilation openings Natural heat radiation Degree of protection IP20 Climatic conditions : Working temperature 0°C - 40°C Working humidity 20% - 80% Relative humidity, no condensation Transport and storage temperature -20°C - 60°C...
  • Page 23: Electromagnetic Emission

    Document No.: YF.SMS231201 Model: C411W Version: A2 Electromagnetic Emission The LCD Monitor is intended to be used in professional healthcare facility environments such as clinics, labs and hospitals. EMC and during installation require special precautions. You need to carefully read the EMC Information and the “PRECAUTIONS”...
  • Page 24: Timing

    Document No.: YF.SMS231201 Model: C411W Version: A2 8 Timing DP/DL-DVI input signal format Horizontal Vertical Display Mode Pixel Clock (MHz) Frequency (KHz) Frequency (Hz) 640 x 480 31.5 59.9 25.2 1024 x 768 48.4 60.0 65.0 1280 x 1024 64.0 60.0...
  • Page 25: Cleaning And Disinfection

    Document No.: YF.SMS231201 Model: C411W Version: A2 9 Cleaning and Disinfection Periodic cleaning is recommended to keep the monitor clean and to prolong its operation lifetime. Note:  Be sure to unplug the power cable from the machine when cleaning your LCD monitor.
  • Page 26: Troubleshooting

    Document No.: YF.SMS231201 Model: C411W Version: A2 10 Troubleshooting If a problem persists even after applying the suggested remedies, contact the manufacturer. Problems Points to Check with Possible Solutions Check that the power cord is correctly connected. If the problem 1.
  • Page 27: Performance Data

    11 Appendix A 11.1 Performance Data The C411W display performance was evaluated according to FDA`s guidance “Technical Performance Assessment of Digital Pathology Whole Slide Imaging Devices”, April 20, 2016, (TPA guidance), section IV(A)(11)(b). The results are summarized in the table below.
  • Page 28 Document No.: YF.SMS231201 Model: C411W Version: A2 Beacon C411W Display Performance Data 12. Color gamut Measurement of the color gamut 2D color gamut area with respect to volume IDMS v1.03, section sRGB: 110.4% 5.18.1 Relative Gamut Area 2D color gamut area overlapped with sRGB: 98.5%...
  • Page 29: Markings And Symbols

    Document No.: YF.SMS231201 Model: C411W Version: A2 11.2 Markings and symbols The markings and symbols on the monitor, power supply and packing have the following meanings(nonrestrictive list). Caution Earth(ground) Warning Batch number This symbol indicates the need for the user to consult the instructions...
  • Page 30: Conformity Declaration

    Document No.: YF.SMS231201 Model: C411W Version: A2 11.3 Conformity declaration This equipment satisfies the following conditions: 1. To avoid interference with radio or TV receiving, please use the provided power adapter and cable; Using other cable and power adapter may interfere the other electronic equipment.
  • Page 31: Rohs Information

    Document No.: YF.SMS231201 Model: C411W Version: A2 11.4 RoHS information Explanation of Pollution Control Label This symbol indicates the product contains hazardous materials in excess of the limits established by the Chinese standard SJ/T11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products. The number in the...
  • Page 32 Distributed by: Philips Medical Systems Nederland B.V. Veenpluis 6 5684 PC Best The Netherlands Shenzhen Beacon Display Technology Co., Ltd 15F, Building 6, Hengda Shishang Huigu(East), Fulong Road, Dalang Subdistrict, Longhua, Shenzhen, 518109, P.R. China Published in China Tel:+86 755 3686 8363...

Table of Contents