Advertisement

Note: When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver's door pin
switch in order to begin the passive arming sequence.
RF Programmable Features:
Feature Selection
1st Door L/UL
2nd Accy Lock
3rd Accy. UL
4th Passive Locks
5th Passive/Active Arm
6th Voltage Sense
7th Siren/Horn
8th Horn Chirp
9th Override Method
10th Two Step Unlock
11th Chirp Delete From Tx On
To program these selectable features;
Turn ignition on No response
Press and release the valet switch 3 times
Within 3 seconds, turn ignition Off
First
Then On
Press transmitter Lock button to change
Press transmitter Lock button to change
Second
Press and release the valet switch
Press transmitter Lock button to change
Third
Press and release the valet switch
Press transmitter Lock button to change
Press transmitter Lock button to change
Fourth
Press and release the valet switch
Press transmitter Lock button to change
Fifth
Press and release the valet switch
Press transmitter Lock button to change
Sixth
Press and release the valet switch
Press transmitter Lock button to change
Seventh
Press and release the valet switch
Press transmitter Lock button to change
Press transmitter lock button to change

SELECTABLE FEATURES

1 Chirp
2 Chirps
1 Sec.
3.5 Sec.
Auto Lock On
Auto Lock Off
Auto UL Dr.
Auto UL All
Passive
Active
Passive Arm
Active Arm
Voltage Sense Hardwire
Siren/Horn
Siren Only
10mS
16mS
Custom Code
Valet
On
Off
Off
Action
or
or
o r
o r
o r
o r
Model AX-200
Installation Manual
3 Chirps
4 Chirps
1 Sec L, Dbl. U/L
Auto UL Off
Horn Only
30mS
System Response
1 Chirp - LED 1 flash
Short chirp, then long chirp
1 chirp = 1 second door locks
2 chirps = 3.5 second door locks
3 chirps = 1 sec. lock, dbl 1 sec. unlock
2 chirps = auto locks off
1 chirp = auto locks on
3 chirps = auto unlock off
1 chirp = auto unlock dr.
2 chirps = auto unlock all
2 chirps = active locks
1 chirp = passive locks
2 chirps = active arming
1 chirp = passive arming
2 chirps = hardwire
1 chirp = voltage sense
1 chirp = siren and horn output
2 chirps = siren output only
3 chirps = horn output only
Default
1 Sec.
Auto Lock Off
Auto UL Off
Active
Active Arm
Hardwire
Siren/Horn
16mS
Valet
Off
Off
128-6994
1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1286994 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Audiovox 1286994

  • Page 1 Model AX-200 Installation Manual SELECTABLE FEATURES Note: When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin switch in order to begin the passive arming sequence. RF Programmable Features: Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps Default...
  • Page 2 Eight Press and release the valet switch 2 chirps = horn chirp output 16mS Press transmitter Lock button to change 3 chirps = horn chirp output 30mS Press transmitter Lock button to change 1 chirp = horn chirp output 10 mS Ninth Press and release the valet switch 2 chirps = valet switch override operation...
  • Page 3 Be sure to check behind the dash for adequate clearance for the body of the switch and to confirm that the drill will not damage any existing components as it passes through the dash. You should also make certain that the back of the switch is accessible for wiring later in the installation. Shock Sensor: Select a solid mounting surface for the shock sensor on the firewall inside the passenger compartment and mount the sensor using the two screws provided.
  • Page 4 Green Wire: - DOOR TRIGGER If the vehicle’s courtesy light switches have a ( - ) ground output when the door is opened (GM and most Imports), you must connect this wire to the negative output from one of the door switches. WARNING: Do not use the green wire if the vehicle has + 12 volt output type door switches.
  • Page 5 NOTE: When wiring this feature in vehicles with factory equipped delay lighting circuits, it is best to connect to the output of the timer which feeds the dome light, rather than at the door switch. This will ensure that the dome light pulses when the alarm is triggered. Blue/White Wire: ( - ) Instant Trigger Zone 1 This is an instant on ground trigger wire.
  • Page 6 These applications require the use of additional components which may include relays, fixed resistors, or for convenience, the AS 9159 Door Lock Interface. Refer to the AUDIOVOX Door Lock Wiring Supplement and or the Audiovox fax back service for information on your particular vehicle for properly connecting to these types of circuits.
  • Page 7 Antenna Wire: Be sure to extend the thin black antenna wire to it’s full length and cable tie into place where it cannot be damaged. Avoid wrapping this wire around major, high current wire looms. Adjusting the Shock Sensor: If used, the sensitivity of the pre - detect circuit is automatically set 30% less sensitive than the full trigger circuit.
  • Page 8 © 2003 Audiovox Electronic Corp. 150 Marcus Blvd., Hauppauge, N.Y. 11788 128-6994 128-6994 8 of 8...

This manual is also suitable for:

Ax-200

Table of Contents