EXTERIOR ACTUATOR
(MS42 family)
double-gang or single-gang
+
double-gang or single-gang
+
Wall Decal - exterior
(74.0017)
VACANT WHEN GREEN
OCCUPIED WHEN RED
75.0086.02 MAGIC SWITCH RESTROOM KIT Installation Guide 20250119
MAGIC SWITCH
INTERIOR ACTUATOR - opening
(MS42 family)
double-gang or single-gang
+
COMPATIBLE MOUNTING BOXES
(MAGIC SWITCH Surface-Mount Boxes)
double-gang or single-gang
COMPATIBLE WALL DECALS
not required
RESTROOM KIT
®
Touchless restroom kit for single occupancy,
normally locked/unlocked restrooms
Power Supply Cabinet + Logic Module
(10PS-RR)
Door Position Switch
(50.5283)
INTERIOR ACTUATOR - locking
double-gang or single-gang
double-gang or single-gang
Wall Decal - interior
(MS42 family)
+
+
(74.0019)
UNOCKED WHEN GREEN
LOCKED WHEN RED
Page 1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BEA MAGIC SWITCH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Halma BEA MAGIC SWITCH

  • Page 1 MAGIC SWITCH RESTROOM KIT ® Touchless restroom kit for single occupancy, Visit website for normally locked/unlocked restrooms available languages of this document. Power Supply Cabinet + Logic Module (10PS-RR) Door Position Switch (50.5283) EXTERIOR ACTUATOR INTERIOR ACTUATOR - opening INTERIOR ACTUATOR - locking (MS42 family) (MS42 family) (MS42 family)
  • Page 2: Installation Tips

    PRECAUTIONS ‰ Shut off all power going to header before attempting any wiring procedures. ‰ Maintain a clean and safe environment when working in public areas. ‰ Constantly be aware of pedestrian traffic around the door area. ‰ Always stop pedestrian traffic through the doorway when performing tests that may result in CAUTION unexpected reactions by the door.
  • Page 3 MOUNT CABINET If necessary for the application, run site power and all device cabling through the appropriate knockout on the power supply cabinet. Holding the power supply cabinet in the desired location, mark mounting holes and then drill pilot holes, insert wall anchors (if necessary), and then fasten screws* 75% into the anchors.
  • Page 4 INSTALL ACTUATORS Determine appropriate mounting locations for all three actuators. IMPORTANT: Ensure that the two interior actuators are spaced at least 12” apart (measured center-point to center-point) to avoid radar interference. MOUNTING BOX (optional) Install the mounting box using the pilot hole locations. Do not drill outside of the pilot hole locations (see images, right).
  • Page 5: Terminal Locations

    CHECKPOINT CAUTION LOGIC MODULE OUTPUT Be sure that the BR3-X WET/DRY jumpers available at Relay 1 are set appropriately for your application before applying power to the system. PRECAUTIONS TO OBSERVE WHEN USING A ‘WET’ OUTPUT • Never change the jumper settings when the module has power connected to it or when a load is applied.
  • Page 6 PROGRAMMING COMPONENTS ACTUATORS Following power-on, check functionality for all actuators. If adjustments are needed, remove the faceplate from the actuator by using a flathead screwdriver to loosen the assembly at the top or bottom set of snap fittings.* This allows access to the PCBA in order to make adjustments to the DIP switches and potentiometer.
  • Page 7 PROGRAMMING COMPONENTS LOGIC MODULE 1. The BR3-X is defaulted to the “00” function. Based on the restroom application, you must change this setting to either “nL” or “nU”. 2. Once the BR3-X function is set, select the hold time (h1, h2) and delay time (d1). •...
  • Page 8 MS42 SETTINGS VIA REMOTE CONTROL When all actuators are disengaged RANGE To change these settings by remote control, the potentiometer must be set to minimum. small > > > > > > > > large OUTPUT To change these settings by remote control, DIP 2 (Output/Buzzer bank) must be set to OFF. MODE pulse toggle...
  • Page 9 BUZZER To change these settings by remote control, DIP 3 (Output/Buzzer bank) must be OFF. short long BUZZER TONE MS42 SETTINGS VIA REMOTE CONTROL When the locking actuator is engaged COLOR LOGIC* Discard wall decals for actuators if LED color green blue yellow...
  • Page 10: Technical Specifications

    Specifications are subject to change without prior notice. TECHNICAL SPECIFICATIONS All values measured in specific conditions. POWER SUPPLY ENCLOSURE Agency listings UL Listed for Access Control Systems (UL294*) - file #BP6714 cUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment CSFM - California State Fire Marshal Approved MEA - NYC Dept.
  • Page 11 MS42 TECHNICAL SPECIFICATIONS Technology microwave motion sensor Radiated frequency 24.150 GHz Radiated power < 20 dBm EIRP Radiated power density < 5mW/cm Detection range 4 – 24” (adjustable) Detection mode motion (bidirectional) Speed of target to create 5Hz (min) or ± 1 in/s detection 200Hz (max) or ±...
  • Page 12: Troubleshooting

    TROUBLESHOOTING Door does not open or Bad or no power supply Check power supply. If LED switches on or lock upon hand wave flashes, power connection is OK. Detection range is too short Adjust the detection range. Remove any metal plates in front of the sensor. Incorrect wiring / connection Check wiring and relay connection.