3. If you notice any errors or omissions in this instruction manual, please do not hesitate to contact KOKEN. 4. KOKEN is not liable for any damages or other consequences resulting from the use of the product in a manner...
Index 1. Outline and Features ............................2. Components ..................................3. Set up ........................................ 4. Maintenance ..................................5. Specifications ................................6. Options .....................................
1. Outline and Features Outline The optional kit for the Obstetric Assistant Model Set (Hiroko) enables trainees to examine the status of the postpartum uterus. Features ・ Used together with the Obstetric Assistant Model Set, this kit can reproduce the status of the uterus and abdomen immediately after delivery.
3. Set up 3-1. Fitting the Uterine Involution Observation Kit to the Obstetric Assistant Model Complete the following steps before training begins: (1)Set the Uterus Model to the Fixation Base. Ensure that the Uterus Model has been fi xed till the line shown in the picture above.
Page 7
(3)Remove the Abdominal Wall of the Obstetric Assistant Model. (4)Insert the Kit prepared in the step (2) into the model. Ensure that the Fixation Base has been fi xed till the end.
Page 8
(5)Cover the Abdominal Wall over the model and attach the metal plates and magnets such that they are connected to each other. Please rest assured that the wrinkles on the Abdominal Wall will not aff ect the training.
Page 9
3-2. Fitting the Uterine Involution Models (Optional) to the Obstetric Assistant Model Subinvolution, Normal, Normal, Normal, Day 1 Day 1 Day 3 Day 5 (1)Uncover half of the Abdominal Wall and remove the provided Uterus Model. (2)Insert an optional Uterine Involution Model.
Page 10
(3) Cover the Abdominal Wall over the model and attach the metal plates and magnets such that they are connected to each other. Please rest assured that the wrinkles on the Abdominal Wall will not aff ect the training.
4. Maintenance 4-1. Abdominal Wall Wipe off dirt with a damp towel, cloth, or alcohol swab and let it dry. After drying, apply baby powder (commercially available) all over the model. Do not wash the magnetic areas with water to prevent rusting. 4-2.
5. Specifications Uterus Model Quantity Length Width Height Weight Approx. 18 cm Approx. 11 cm Approx. 10 cm Approx. 1 kg Fixation Base Quantity Length Width Height Weight Approx. 23 cm Approx. 38 cm Approx. 13 cm Approx. 1.4 kg Abdominal Wall Quantity Length...