Page 1
READ ALL INSTRUCTIONS CONTAINED IN THIS MANUAL BEFORE USING THIS PRODUCT. Save these instructions for future reference. Failure to read and follow the warnings and instructions within this instruction manual could result in property damage, serious injury or death. FloodStop® Pump Tech Support: 1-833-786-7779...
WARNING! The FloodStop® System has not been investigated for use in or around swimming pools, marine areas, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common.
It is also not engineered to be run continuously as a “fountain” or “waterfall” pump. • Do not use where water re-circulates. • Not designed for use as a swimming pool drainer. • Operating water depth: minimum 1in. NOTE: Parts are not shown to scale. FloodStop® Pump Tech Support: 1-833-786-7779...
CAUTION: This hole is for anti-airlock purposes only. Leakage of air or water is normal and necessary. DO NOT REMOVE OR PLUG THIS HOLE! FloodStop® Pump Tech Support: 1-833-786-7779...
Page 5
• Unscrew the stainless screws, and remove the volute and gasket • Use a flathead screwdriver to hold the shaft, then turn the impeller counterclockwise to release the impeller. Remove debris from around the shaft and on/under the impeller. • Reassemble. FloodStop® Pump Tech Support: 1-833-786-7779...
3. There is airlock. 4. Use a shorter hose. 4. The hose length is too 5. Reassemble the impeller. long. 6. Replace the impeller. 5. The impeller is loose on the shaft. 6. The impeller is broken. FloodStop® Pump Tech Support: 1-833-786-7779...
Need help?
Do you have a question about the FSDSKIT and is the answer not in the manual?
Questions and answers