Advertisement

Quick Links

EN
EASY CORE C 400
USER MANUAL v1.4(1.0)EN
ul. Wojkowicka 21, 41-250 Czeladź, Poland
tel. +48 32 763 77 77
fax: +48 32 763 75 94
mikster.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EASY CORE C 400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mikster EASY CORE C 400

  • Page 1 EASY CORE C 400 USER MANUAL v1.4(1.0)EN ul. Wojkowicka 21, 41-250 Czeladź, Poland tel. +48 32 763 77 77 fax: +48 32 763 75 94 mikster.eu...
  • Page 2: Table Of Contents

    User manual EASY CORE C 400 v1.4(1.0)EN CONTENTS CONTENTS ......................................2 TECHNICAL SPECIFICATIONS ..............................3 INSTALLATION DATA ................................4 ENTRY......................................4 OPERATION DESCRIPTION ..............................4 CONSTRUCTION DESCRIPTION .............................. 5 5.1. CONNECTION PT100 ............................... 5 5.2. CONNECTION THERMOCOUPLE ............................ 6 KEYBOARD WITH DISPLAY ..............................6 6.1.
  • Page 3: Technical Specifications

    User manual EASY CORE C 400 v1.4(1.0)EN 1. TECHNICAL SPECIFICATIONS 24 V DC ±10 % Power supply: 1,5 W (max 100 mA) Power consumption: Display: OLED 0,96" Inputs: Analog AI: 4x PT100 (3-wire) / thermocouples K,J; Digital DI: 1x 24 V DC;...
  • Page 4: Installation Data

    User manual EASY CORE C 400 v1.4(1.0)EN 2. INSTALLATION DATA 3. ENTRY The EasyCoreC400 module has been designed to measure temperatures from up to 4 external measurement probes. The device converts the temperature measurement(s) into a current signal that is calculated based on the average, minimum or maximum value of the active temperature channels.
  • Page 5: Construction Description

    User manual EASY CORE C 400 v1.4(1.0)EN 5. CONSTRUCTION DESCRIPTION 5.1. CONNECTION PT100 How to connect the PT-100 probe. Recommended 3-wire probes: www.mikster.eu...
  • Page 6: Connection Thermocouple

    User manual EASY CORE C 400 v1.4(1.0)EN 5.2. CONNECTION THERMOCOUPLE How to connect thermocouple probes. Supported types: K or J: 6. KEYBOARD WITH DISPLAY Display OLED „Back/Exit” button „Down” button „UP” button „Enter/OK” button 6.1. KEYBOARD DESCRIPTION The keyboard consists of 4 buttons: “Back/Exit”...
  • Page 7: Display Description

    User manual EASY CORE C 400 v1.4(1.0)EN 6.2. DISPLAY DESCRIPTION Active channel Inactive channel Channel number Time Date Using button we open the information screen: Pressing again we open a screen with configuration information: 7. CONFIGURATION FUNCTIONS (MENU) To enter the MENU, press button from the main screen.
  • Page 8: Outputs

    User manual EASY CORE C 400 v1.4(1.0)EN To ensure proper operation of the device, the following parameters must be configured: • „Name” – sensors name „Type” – selection of the sensor type: • Pt100 - resistive; TC-J - J type thermocouple;...
  • Page 9: Inputs

    User manual EASY CORE C 400 v1.4(1.0)EN 7.3. INPUTS 7.3.1. CONFIGURATION INPUT DI1 DI1 is a binary input. Applying or losing voltage to the input causes the module to start or stop recording the measured temperatures. Triggering the registration process via input must be previously defined in the registration configuration (MENU/Regist.).
  • Page 10: Registration

    8. CONNECTION TO A PC To connect the recorder to a PC, use a USB-485 converter. It is recommended to use the MCU-01 converter from MIKSTER. The converter should be connected to the device on the port (marked "RS485") with a 2-wire cable in the following places: •...
  • Page 11: Configurator Easy Core

    MIKSTER Sp. z o.o. Disclaimer The company MIKSTER Sp. zoo. makes no representations or warranties, express or implied, with respect to this publication, including without limitation any implied warranties or conditions of merchantability or fitness for a particular purpose. Moreover, MIKSTER Sp. z o.o.

Table of Contents