User manual EASY CORE C 400 v1.4(1.0)EN 1. TECHNICAL SPECIFICATIONS 24 V DC ±10 % Power supply: 1,5 W (max 100 mA) Power consumption: Display: OLED 0,96" Inputs: Analog AI: 4x PT100 (3-wire) / thermocouples K,J; Digital DI: 1x 24 V DC;...
User manual EASY CORE C 400 v1.4(1.0)EN 2. INSTALLATION DATA 3. ENTRY The EasyCoreC400 module has been designed to measure temperatures from up to 4 external measurement probes. The device converts the temperature measurement(s) into a current signal that is calculated based on the average, minimum or maximum value of the active temperature channels.
User manual EASY CORE C 400 v1.4(1.0)EN 5. CONSTRUCTION DESCRIPTION 5.1. CONNECTION PT100 How to connect the PT-100 probe. Recommended 3-wire probes: www.mikster.eu...
User manual EASY CORE C 400 v1.4(1.0)EN 5.2. CONNECTION THERMOCOUPLE How to connect thermocouple probes. Supported types: K or J: 6. KEYBOARD WITH DISPLAY Display OLED „Back/Exit” button „Down” button „UP” button „Enter/OK” button 6.1. KEYBOARD DESCRIPTION The keyboard consists of 4 buttons: “Back/Exit”...
User manual EASY CORE C 400 v1.4(1.0)EN 6.2. DISPLAY DESCRIPTION Active channel Inactive channel Channel number Time Date Using button we open the information screen: Pressing again we open a screen with configuration information: 7. CONFIGURATION FUNCTIONS (MENU) To enter the MENU, press button from the main screen.
User manual EASY CORE C 400 v1.4(1.0)EN To ensure proper operation of the device, the following parameters must be configured: • „Name” – sensors name „Type” – selection of the sensor type: • Pt100 - resistive; TC-J - J type thermocouple;...
User manual EASY CORE C 400 v1.4(1.0)EN 7.3. INPUTS 7.3.1. CONFIGURATION INPUT DI1 DI1 is a binary input. Applying or losing voltage to the input causes the module to start or stop recording the measured temperatures. Triggering the registration process via input must be previously defined in the registration configuration (MENU/Regist.).
8. CONNECTION TO A PC To connect the recorder to a PC, use a USB-485 converter. It is recommended to use the MCU-01 converter from MIKSTER. The converter should be connected to the device on the port (marked "RS485") with a 2-wire cable in the following places: •...
MIKSTER Sp. z o.o. Disclaimer The company MIKSTER Sp. zoo. makes no representations or warranties, express or implied, with respect to this publication, including without limitation any implied warranties or conditions of merchantability or fitness for a particular purpose. Moreover, MIKSTER Sp. z o.o.
Need help?
Do you have a question about the EASY CORE C 400 and is the answer not in the manual?
Questions and answers