Summary of Contents for Immergas MAGIS HERCULES MINI HYDRO 5
Page 1
MAGIS HERCULES Instructions and recom- MINI HYDRO mendations Installer 5/8/12 User Control Panel Maintenance technician Heat pump comprising: Technical Data - indoor unit UI MHMH - outdoor unit UE HYDRO HP 5/8/12...
Parameters menu, information and P.C.B. programming ........................53 Fault and anomaly signals ..................................81 Instructions for maintenance and initial check ........................91 General recommendations ..................................91 4.2 Initial check ........................................92 4.3 Yearly appliance check and maintenance ..............................92 Finned air coil maintenance ..................................93 ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 3
Technical data ..................................119 Technical data table ....................................119 Product fiche Magis Hercules Mini Hydro 5 (in compliance with Regulation 811/2013) ..............122 Table 2 Regulation 813/2013 ..................................123 Product fiche Magis Hercules Mini Hydro 8 (in compliance with Regulation 811/2013) ..............124 Table 2 Regulation 813/2013 ..................................125...
Dear Customer Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Im- mergas customer you can also count on a Qualified Authorised After-Sales Technical Assistance Centre, prepared and updated to guarantee the constant efficiency of your products.
Law. • Improper installation or assembly of the Immergas device and/or components, accessories, kits and devices can cause unex- pected problems for people, animals and objects. Read the instructions provided with the product carefully to ensure proper installation.
The user must not dispose of the appliance at the end of its service life as municipal waste, but send it to appropriate collection centres. PERSONAL PROTECTIVE EQUIPMENT SAFETY GLOVES EYE PROTECTION SAFETY FOOTWEAR ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- UE Hydro HP 5/8/12 outdoor unit (hereinafter called, outdoor unit or UE Hydro HP 5/8/12). The product Magis Hercules Mini Hydro 5/8/12 is perfectly operational only if the two units are correctly powered and interconnected. The UI MHMH indoor unit was designed solely for floor installation for heating and air conditioning and to produce domestic hot water for domestic use and similar purposes.
Page 8
The manufacturer declines all liability in the event of damage caused by appliances removed from other systems or for any non-conformities with such equipment. Only a professionally enabled company is authorised to install Immergas appliances. Check the environmental operating conditions of all parts relevant to installation, referring to this booklet.
Page 9
For correct operation of the system, check that the minimum flow rate in operating conditions never drops below 500 l/h for Magis Hercules Mini Hydro 5-8 models and 750 l/h for Magis Hercules Mini Hydro 12 models without system integrative resistance and 1000 l/h if there is the system integrative resistance (optional).
Power Supply 2 / Optional electric resistance CH - Max Temp / Max Press Maximum temperature / Maximum pressure in CH mode DHW - Max Temp / Max Press Maximum temperature / Maximum pressure in DHW mode ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 11
Configuration plate At the end of installation, use a permanent marker to Magis Hercules Mini Hydro 5 mark the configuration label with installed indoor unit (UI MHMH + UE HYDRO HP 5) + outdoor unit combination. Magis Hercules Mini Hydro 8...
Electrical connections MHT - Flow from heat pump Filling System return System flow Wall-mounted hydraulic connection with Immergas tem- Domestic hot water outlet plate (*) DHW (Domestic hot water) water inlet Direct hydraulic connection in heat pump (*) Pump (optional)
UCS - EFS G 1" G 3/4" G 3/4" G 3/4" G 1" G 3/4" MINIMUM INDOOR UNIT INSTALLATION DISTANCES Key (Fig. 4): 800 mm 300 mm 30 mm 30 mm 10 mm (maximum 150 mm) ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
In order to meet the system requirements established by EN 1717 in terms of pollution of drinking water, we recommend installing the IMMERGAS anti-backflow kit to be used upstream of the cold water inlet connection of the Indoor Unit. We also recommend using category 2 heat transfer fluid (ex: water + glycol) in the Indoor Unit primary circuit (heating and/or cooling circuit), as defined in stand- ard EN 1717.
1. Remove the protection caps (a) and loosen the screws (b) to remove the aesthetic profile (c) (Fig. 6). 2. Open the cover door (f) to make it tilt. Remove the protection caps (d), loosen the two upper front screws and the lower screws (e) to remove the cover (f) (Fig. 7). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 16
• Phase fuse for DHW integrative resistance (F2, Fig. 43): 12 A aM 500V CH10. If fuses in the main electrical panel are to be replaced, this must also be done by qualified personnel. The power supply cable (l) must be laid as shown (Fig. 11). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 17
X108 and X109 terminal blocks of the control panel must be separated from the power cables and secured outside the corrugated duct of the power supply cable (1, fig. 11) using the specific openable cable ties supplied with the product. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 18
- Connection between the control panel and main panel • Zone 1 pump; 10 - Heat pump flow probe connection • Zone 2 pump; - Cable gland • Zone 2 Mixing Valve; • Power connection of the expansion kit. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 19
(Fig.15). The power supply of the outdoor unit must be independent from the indoor unit. Configure the parameter "HP Model" as indicated in the paragraph (Par. 3.3) according to the type of connected outdoor unit. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Zone 1 = 41 Slave address: Address to configure according to the zone where the device is installed Zone 2 = 42 Zone 3 = 43 Baud Rate 9600 Parity bit Even Stop bits Heat pump control ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Modbus 1 - 8 - E - 1 (Type) DIP 8 9600 bit/s (Speed) In the same zone, only one of the two optionals between Zone remote panel and Modbus temperature and humidity room probe can be installed. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
The Indoor Unit is prepared for the application of room chrono-thermostats, which are available as optional kits. A maximum of 3 temperature controllers can be applied directly to the appliance. All Immergas chrono-thermostats are connected with 2 wires only. Carefully read the user and assembly instructions contained in the accessory kit.
2-relay kit (optional). Connect as shown in the kit’s instructions sheet. With the installation of a Immergas dehumidifier, it is possible to activate either the dehumidification function in neutral air or in cooled air (see dehumidifier kit manual for more details on the function).
For further information, consult the relative instruction sheet. 1.17 KITS AVAILABLE ON REQUEST Check the complete list of kits available and which can be combined with the product, consult the Immergas website, the Im- mergas Price List or the technical-commercial documentation (catalogues and data sheets).
Key (Fig. 18, 19, 20, 21) C.H. flow temperature offset Maximum flow set Central heating / C.H. flow set Minimum flow set Cooling flow temperature offset External minimum temperature Cooling flow set External maximum temperature ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
The antifreeze liquid must not be harmful to one's health. The materials used for the central heating circuit of Immergas units resist ethylene and glycol based antifreeze liquids (if the mixtures are prepared perfectly). Adding glycol lowers the freezing point of water.
1.21 SYSTEM MINIMUM WATER CONTENT In versions Magis Hercules Mini Hydro 5 and Magis Hercules Mini Hydro 8, the water content sufficient for proper operation of the sys- tem (30l) is provided by the hydraulic manifold with the primary water inertial storage tank functions.
= Storage tank temperature TB (°C) = With integration electrical resistance = Without electrical resistance enabled = For outdoor temperatures below -20°C, the capacity of the heat pump is not guaranteed. TE (°C) -25 -20 ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Using a screwdriver and inserting it in the groove, turn the shaft of the pump in its direction of rotation until it blocks. After this, reapply the screw and power the pump back up. Hot water could escape. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 32
Refer to the relative instruction manual for head losses of the outdoor unit only. It is recommended to install the indoor unit at least 10 metres from the outdoor unit. Magis Hercules Mini Hydro 5 Indoor unit (UI MHMH) + Outdoor unit (UE HYDRO HP 5)
Page 33
= Head available to the PWM system 50% = Power absorbed by pump PWM 50% = Power absorbed by pump PWM 80% = Flow rate (l/h) = Head (kPa) = Circulator pump absorbed power (W) ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 34
= Head available to the PWM system 50% = Power absorbed by pump PWM 50% = Power absorbed by pump PWM 100% = Flow rate (l/h) = Head (kPa) = Circulator pump absorbed power (W) ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- Unscrew the bracket screws (9) and remove the expansion vessels (10). - Loosen the bracket (2) fixing screws (1) and remove the bracket itself. - Slide the storage tank (3) to the front. Work in reverse order to assemble the storage tank unit. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 36
Connect the supplied flexible hose to the drainage elbow (1) and pull it out at the bottom of the unit as shown in figure 29 (pos. 2 or 3). Make sure dust, debris and/or insects cannot enter this hose. Also make sure that the liquid contained in it cannot freeze. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
8 bar safety valve D.H.W. probe Electrical connection compart- Flow from heat pump Solar probe ment Return to heat pump Sacrificial anode System manometer 3-way valve (motorised) DHW electrical resistance System expansion vessel System return fitting ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
– in the event of damage to the cable, switch off the appliance and contact exclusively qualified staff for replacement; – if the appliance is not to be used for a certain period, disconnect the main Indoor Unit external switch. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
“annual check and maintenance of the appliance”, in compliance with national, regional, or local standards in force. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
4. At the end, close the draning valve. 5. Close all previously opened vent valves. If fluid containing glycol was added to the system circuit, make sure it is recovered and disposed of in accordance with standard EN 1717. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Never use abrasive or powder detergents. 2.8 PERMANENT SHUTDOWN Should the system be shut down permanently, have professional staff carry out the procedures, making sure that the electrical and water supply lines have been previously shut off. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Depending on the system's configuration, the main screen displays various information regarding the system itself, amongst which: ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 43
Activated Summer with Enabled Enabled Disabled Activated Cooling Winter Enabled Disabled Enabled Activated Stand-by Disabled Disabled Disabled Activated The Anti-legionella function is NOT active in the following modes: Off, Standby and Active holiday mode ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 44
At the end of the modification, press “OK” to confirm the change and go back to the previously selected menu item. • Exit without saving If at the end of the modification you press “RESET”, you will return to the previously selected menu item without confirming the mod- ification. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
In this mode the system allows the production of domestic hot water and room central heating / C.H. and ensures protection (Fig. 33). List of functions The following functions can be set on the internal unit: – DHW (Domestic hot water); – Central heating / C.H.; – Cooling; – Dehumidify. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 46
DHW / Boost Function = On DHW (Domestic hot water) operation takes place with the contribution of both the heat pump and the electrical resistance, with a logic that minimises storage tank charging time. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 47
- request from TA (Room Thermostat); - request from Immergas Remote Control (Temperature Humidity Probe or Remote Panel). To check which device was set during configuration, verify the type of information under the zone symbol of the panel, as described in paragraph 3.1.
Page 48
Zone / Settings / Dehumidification. In central heating or cooling request mode, if the temperature of the water in the system meets the request, the system can work simply by activating the circulator pump. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 49
Clock and programs / Time slots IMPOSTA DATA E ORA Calendars Calendar 8 10 12 14 16 18 20 22 24 [1] 06:15 - 08:30 [3] 17:45 - 23:00 [2] 11:30 - 13:45 [4] 24:00 - 24:00 ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 50
User / Disable HP = Yes and the start and end times of disabling. Integration Disabling The use of the integration electrical resistances can be permanently disabled by setting User / Disable Integration = Yes ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 51
'Special Parameters' menu, the heat pump is switched on until the set antifreeze protection temperature increased by 1°C is reached. To enable this function, a zone remote panel or a zone humidity temperature probe is required. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 52
If the temperature of the storage tank drops below 4°C, the system automatically switches on one of the generators available based on the environmental conditions, heat pump or electric resistance, to heat the storage tank until it reaches a temperature of 5°C. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Anti-legion.cycle day None function. - Sunday / All Time after which an alarm is signalled for incomplete Max antilegion. time 1 - 48 (h) anti-legionella cycle. S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 54
DHW or to the system. Time after which an alarm is signalled for incomplete DHW Max time DHW 1 - 48 (h) (Domestic hot water). S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 55
Comfort = zone in comfort mode Manual = zone in manual mode Yes = Zone TA contact closed Room Thermostat Stat. No = TA contact open S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 56
0-23h Hourly disable end Time of dehumidification request disabling phase end 0-23h Dehum. flow set Flow setpoint for zone 1 in dehumidification mode 5-50°C 20°C S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 57
Maximum flow set calculated, acceptable by the dehumidifi- Dehum. alarm set 10 - 50 °C 25 °C Ext. probe modul. Thermoregulation with external probe No / Yes S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 58
With the external probe present, it defines at what minimum Max. outside temp. external temperature the system must operate at the 20 ÷ 45 °C 35 °C maximum flow temperature S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 59
Off / Manual / Operation mode Auto Auto = Zone in Automatic mode Auto Manual = zone in manual mode C.H. Cooling Dehumidification S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 60
Hourly disable end Time of dehumidification request disabling phase end 0-23h Dehum. flow set Flow setpoint for zone 2 in dehumidification mode 5-50°C 20°C S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 61
Ext. probe modul. Thermoregulation with external probe No / Yes Determines the type of zone Zone type Direct = DIR MIX/DIR mixed = MIX S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 62
With the external probe present, it defines at what minimum Max. outside temp. external temperature the system must operate at the 20 ÷ 45 °C 35 °C maximum flow temperature S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 63
Off / Manual / Operation mode Auto Auto = Zone in Automatic mode Auto Manual = zone in manual mode C.H. Cooling Dehumidification S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 64
Hourly disable end Time of dehumidification request disabling phase end 0-23h Dehum. flow set Flow setpoint for zone 3 in dehumidification mode 5-50°C 20°C S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 65
Ext. probe modul. Thermoregulation with external probe No / Yes Determines the type of zone Zone type Direct = DIR MIX/DIR mixed = MIX S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 66
20 ÷ 45 °C 35 °C maximum flow temperature Determines the type of zone Zone type Direct = DIR MIX/DIR mixed = MIX S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 67
R + D = Cooling and dehumidification requests in neutral air R + A R + A = Cooling and dehumidification requests in cool air S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 68
Zone 1: Thursday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Friday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Saturday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Sunday CAL1 CAL3,CAL4 S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 69
CAL3,CAL4 CAL1, CAL2, Zone 3: Friday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 3: Saturday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 3: Sunday CAL1 CAL3,CAL4 S = menu entry only visible with "Service" access. (*) if present. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 70
Off / 1 day - 30 Holiday Program functions. At the end of the set days, the previously active days functions will be reset. S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 71
Defines the maximum delivery temperature of the Maximum flow set 25 ÷ 55 °C 45 °C screed heater function Activation Activation of the screed heater function Yes / No S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 72
System resistance System resistance active control DHW resistance 1 Standard DHW (Domestic hot water) resistance active control System state Technical parameter (only for Immergas Assistance) Integration state Technical parameter (only for Immergas Assistance) Output status Technical parameter (only for Immergas Assistance)
Page 73
EU interface rev. date Communication board firmware data Expans.board rev. (H) Revision of the expansion board (top part) Expans.board rev. (L) Revision of the expansion board (bottom part) S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 74
Accessing the menu Faults management / Anomalies log, allows you to consult the type and date on which the last 10 errors were detect- Only an Authorised Technical Service Centre can reset the faults history in order to collect and assess all the diagnostic infor- mation useful for evaluating the operational condition of the system. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 75
Heat pump Heat pump operating parameters sub-menu Integration System integration setting sub-menu Manual drives Submenu for load operation check Special parameters Parameters for various uses S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 76
Enabling frost protection with anti-freeze liquid Yes / No S = menu entry only visible with "Service" access. (*) It is not possible to use the external probe IU (optional) when using DHW recirculation. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 77
Heat pump circulator speed 50 – 100 % 70 % Temperature delta to be maintained with modulating Pump T Delta operation. Automatic vent Not used No / Yes S = menu entry only visible with "Service" access. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 78
If an additional electric resistance is installed and enabled for heating the system, it is necessary to check and, if necessary, change the pump settings to ensure a minimum flow rate of 1000 l/h. Flow rate values below this limit can damage the resistance. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 79
Yes / No tion Menu S = menu entry only visible with "Service" access. (*) If you are within the "Manual drives" menu, the 4-minute time-out for exiting the "Support" menu is not taken into account. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 80
Do not use -1000÷1000 Parameter 15 Do not use -1000÷1000 S = menu entry only visible with "Service" access. (*) It is not possible to activate the recirculation function when using the external probe IU (optional). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- pdc pump blocked; free the pump; Press the Reset button (1). - damaged flowmeter. (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 82
(1). Zone 1 offline device The device connected to zone 1 is offline alarm (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 83
Anomaly coming from the dehumidifier (optional) in The system does not dehumidify in fault alarm zone 2 the relative zone (1) (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 84
An excessively high temperature is detected on the heat High flow temp. block Check the hydraulic circuit (1). pump flow circuit (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 85
Check the settings in the Integration The system does not start. DHW integration menu. absent alarm (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 86
Check the position of the sensor. Check the relative wiring Outdoor unit air temperature sensor error Replace the sensor (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 87
Check the compressor connections. Compressor start-up error (Inverter) Check the resistances between the different phases of the compres- (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 88
Check that the fan is powered. Error of outdoor unit fan no.2 (where present) Check the fuses in the main electrical panel. (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 89
Inverter board error Replace the main board Not present Not present Not present Not present Not present Not present (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 90
Check indoor unit Indoor unit error Not used Check indoor unit Indoor unit error Not used Check indoor unit (1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
These will also compromise the product’s compliance, and the said product may no longer be valid and fail to meet the current regulations. in regard to the above, only use original Immergas spare parts when replacing components. If additional documentation needs to be consulted for extraordinary maintenance, contact the Authorised After-Sales Service.
- Check the integrity of the internal insulation. In addition to yearly maintenance, one must also check the energy efficiency of the thermal system, with frequency and proce- dures that comply with the indications of the technical regulations in force. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- Concentrated and/or rotating water jets are strictly prohibited. Never use fluid with a temperature above 45°C to clean the air heat ex- changers. - Proper and frequent cleaning (approx. every three months) prevents 2/3 of corrosion problems. Clean the air coil using suitable products. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
TECHNICAL DATA MAINTENANCE TECHNICIAN CONTROL PANEL USER INSTALLER 35 36...
Page 95
2 direct zones kit (Optional) DHW recirculation one-way valve (Optional) 2 zone kit (1 direct and 1 mixed) (Optional) Domestic hot water expansion vessel Solar kit (Optional) DHW expansion vessel valve Storage tank draining valve ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
TECHNICAL DATA MAINTENANCE TECHNICIAN CONTROL PANEL USER INSTALLER X200 X203 X109 63-1 64-1 59-1 40-1 41-1 60-1 Key (Fig. 39): Black Orange Supervision board Blue Pink Main panel Brown White Control panel Grey Diagram X102 Diagram X108...
Page 97
Rx-/Tx- Rx+/Tx+ +Vdc 24 Vdc Vout Rx-/Tx- Rx+/Tx+ +24Vdc DIC1 X203 X200 X108 Key (Fig. 40): Diagram X109 Orange Display board Diagram X102 Purple Supervision board Black Pink Condensing unit interface board Blue Touch keyboard Brown White Control panel Cyan Yellow Main panel Green...
Page 98
X105 Terminal board connections diagram 82-2 81-2 83-2 84-2 85-2 82-1 81-1 A(L) B(N) X105 X201 Key (Fig. 41): Blue Supervision board Brown Orange Main panel Purple Electric power supply 1 diagram Pink Yellow ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 99
X102 64-2 63-2 X203 40-2 41-2 X200 59-2 60-2 B1-HP B5-HP Key (Fig. 42): Electric power supply 1 diagram Grey Supervision board Diagram X108 Orange B1-HP - Flow probe Diagram X109 Purple D.H.W. probe Black Pink B5-HP - Return probe Blue System flow-meter Brown...
Page 100
TECHNICAL DATA MAINTENANCE TECHNICIAN CONTROL PANEL USER INSTALLER X204 14 11 24 21 X101 ELECTRIC POWER X100 SUPPLY 1 3.15 A 12 A X210 X201 Key (Fig. 43): Main panel Blue Supervision board 230 Vac, 50 Hz Brown Domestic hot water integration resistance Diagram X102 Cyan Control Phase Fuse (3,15A F 250V 5x20)
Page 101
Interface board - setting switch Key (Fig. 44): Factory setting: do not change ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
During normal operation, the display shows “A0” for 1 second, followed by“30” for 1 second: SEGMENTS VALID COMMUNICATION In case of an error of the Outdoor Unit, a sequence of two digits at a time is displayed: "E" plus Outdoor Unit error code: ERROR CODES SEGMENTS E101 ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Make sure the system pressure and expansion tank factory-set pressure values are within the set limits. The factory-set pressure values of the expansion vessel must be 1.0 bar, the value of system pressure must be between 1 and 1.2 bar. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- with simultaneous mode, the resistance and heat pump are activated simultaneously after the heating wait time. The first served operating mode, in case of contemporaneity, is decided with the parameter: Configuration / Priority ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 105
The system flow temperature drops (it rises in case of cooling) when the room temperature approaches the room setpoint. Modulation with room probe can only be enabled in the presence of a zone remote device. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
It is possible to activate the function only with DHW el. resistance and eventually a thermostatic valve must be installed at the DHW outlet to prevent burns. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
System definition / Multifunction relay 1 o Multifunction relay 2 o Multifunction relay 3 = 7 The operation of the circulator can be further reduced by setting the time slots as desired in the menu: Menu / Clock and programs / Recirculation Program ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
System definition / Max Cool. adjust with a value > 0°C. Following a demand, the correction begins after a time equal to System definition / Activation time and continue by 1°C each System definition / Increase time minutes. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
- with simultaneous mode, the resistance and heat pump are activated simultaneously after the heating wait time. The first served operating mode, in case of contemporaneity, is decided with the parameter: Configuration / Priority ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
For the electrical connection see the reference wiring diagram (Fig. 14). If one or more external electric resistances are installed in combination with one of the two-zone kits (supplied by Immergas), integration must be installed between the UI MHMH indoor unit and the distribution kit.
4.21 DEHUMIDIFICATION BOOST FUNCTION If there is a Immergas remote control, zone remote panel or modbus temperature - humidity probe and a Immergas dehumidifier, it is possible to configure the device to increase the cooling capacity of the zone by activating the dehumidifier in cooled air mode if the ambi- ent temperature read by the probe exceeds the set value by 2°C by modifying the parameter Special parameters / Parameter 4.
Max pump speed and Min pump speed with control logics aimed at minimising consumption and guaranteeing the temperature delta between flow and return defined by the parameter Pump T Delta and corresponding to fixed 5°C. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
The appliance can be configured so that it can be controlled by the external supervision devices such as Dominus or other types of home automation systems (not supplied by Immergas). For the configuration, it is necessary to modify the parameter System definition / System supervision It is not possible to configure both devices simultaneously.
- Remove the plastic protection caps (2) and loosen the screws (3) to remove the aesthetic profile (1). - Open the cover door (4) to make it tilt. - Remove the rubber protection caps (5), loosen the two upper front screws and the lower screws (6) to remove the cover (4) ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 115
- Unscrew the 3 fixing screws (7) on the control panel. - After which, pull the control panel (8) towards you and turn it as shown in the figure 49. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 116
- Unscrew the 4 screws (9). - Open the main panel (10) c as shown in figure 51. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Disassembling the front casing (7) (Fig. 52) - Disassemble the front casing (7) by loosening the two screws (8) and pushing it upwards in order to free it from the fixing slots and pulling it towards you (Det. A). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 118
- Remove the left and right sides (9 and 10) by unscrewing the screws (11 and 12) present; then push slightly upwards to release the sides from their seats and pull upwards (Det. A). ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Outside Air Temperature 35°C - Water Temperature 23°C/18°C Output power 5,00 7,50 12,00 Absorbed power 1,14 1,90 2,77 4,39 3,95 4,33 Outside Air Temperature 35°C - Water Temperature 12°C/7°C Output power 3,90 5,70 9,00 Absorbed power 1,15 1,88 2,73 3,39 3,03 ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 120
DHW maximum operating temperature °C DHW maximum operating pressure kPa (bar) 800 (8) DHW minimum operating pressure kPa (bar) Expansion vessel: Total volume 11,0 Expansion vessel: Pre-charge kPa (bar) 350 (3,5) Sound power and pressure Sound power ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 121
(working range) DHW external temperature without integration °C -25 ÷ +35 (working range) DHW adjustable temperature with integration °C +10 ÷ +65 (working range) DHW external temperature with integration (working °C -25 ÷ +46 range) ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
PRODUCT FICHE MAGIS HERCULES MINI HYDRO 5 (IN COMPLIANCE WITH REGULATION 811/2013) Supplier's name or trademark Immergas S.p.A MAGIS HERCULES Supplier's model identifier MINI HYDRO 5 For space heating Application temperature Average temperature For water heating Stated load profile Average temperature...
Page 123
Contact information: Immergas S.p.A. via Cisa Ligure n.95 (*) For heat pump appliances for space heating and heat pump mixed heating appliances, the nominal heat output Pnominal is equal to the design load for central heating Pdesignh and the nominal heat output of an additional heater Psup is equal to the additional central heating capacity sup(Tj).
Annual energy consumption for water heating (warmer climate condition) Average temperature Seasonal energy efficiency of room heating (colder climate condition) Low temperature Average temperature Seasonal energy efficiency of room heating (warmer climate condition) Low temperature Lwa sound power level outdoors ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 125
Contact information: Immergas S.p.A. via Cisa Ligure n.95 (*) For heat pump appliances for space heating and heat pump mixed heating appliances, the nominal heat output Pnominal is equal to the design load for central heating Pdesignh and the nominal heat output of an additional heater Psup is equal to the additional central heating capacity sup(Tj).
Annual energy consumption for water heating (warmer climate condition) Average temperature Seasonal energy efficiency of room heating (colder climate condition) Low temperature Average temperature Seasonal energy efficiency of room heating (warmer climate condition) Low temperature Lwa sound power level outdoors ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 127
Contact information: Immergas S.p.A. via Cisa Ligure n.95 (*) For heat pump appliances for space heating and heat pump mixed heating appliances, the nominal heat output Pnominal is equal to the design load for central heating Pdesignh and the nominal heat output of an additional heater Psup is equal to the additional central heating capacity sup(Tj).
< 30 % ≥ 30 % ≥ 34 % ≥ 36 % ≥ 75 % ≥ 82 % ≥ 90 % ≥ 98 % ≥ 125 %≥ 150 % ter climate conditions Colder: - ‘V’ = Hotter: + ‘VI’ = the heat loss in the distribution system and the size of the products compared to the size and features of the building. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 129
Parameters to fill in the low temperature package fiche (30/35) Magis Hercules Mini Hydro 5 Parameter Colder zones Average zones Hotter zones "I" "II" "III" 5,94 4,86 5,35 "IV" 2,32 2,09 Magis Hercules Mini Hydro 8 Parameter Colder zones Average zones Hotter zones "I"...
Page 130
< 30 % ≥ 30 % ≥ 34 % ≥ 36 % ≥ 75 % ≥ 82 % ≥ 90 % ≥ 98 % ≥ 125 %≥ 150 % Colder: - __ = Hotter: + ___ = the heat loss in the distribution system and the size of the products compared to the size and features of the building. ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 131
ST.008372/000 Magis Hercules Mini Hydro 5/8/12...
Page 132
Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 immergas.com This instruction booklet is made of ecological paper.
Need help?
Do you have a question about the MAGIS HERCULES MINI HYDRO 5 and is the answer not in the manual?
Questions and answers