Diagnosing Power Problems With The Leds; Power And Cooling Problems; Installation; Table A-2 Power/Rpu Leds - SMC Networks 8748L2 - annexe 1 Installation Manual

L2 gigabit standalone switch
Table of Contents

Advertisement

T
ROUBLESHOOTING

Diagnosing Power Problems with the LEDs

The Power and RPU LEDs work in combination to indicate power status
as follows.
Power LED RPU LED Status
Green
Green
Green
Amber
Green
Off
Amber
Green
Off
Off

Power and Cooling Problems

If the power indicator does not turn on when the power cord is plugged in,
you may have a problem with the power outlet, power cord, or internal
power supply. However, if the unit powers off after running for a while,
check for loose power connections, power losses or surges at the power
outlet. If you still cannot isolate the problem, the internal power supply
may be defective.

Installation

Verify that all system components have been properly installed. If one or
more components appear to be malfunctioning (such as the power cord or
network cabling), test them in an alternate environment where you are sure
that all the other components are functioning properly.
A-2

Table A-2 Power/RPU LEDs

Internal power functioning normally; RPU is present.
Internal power functioning normally; RPU plugged in but
faulty.
Internal power functioning normally; RPU not plugged in.
Internal power faulty; RPU delivering power.
Both internal power and RPU unplugged or not functioning.