Page 1
Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw upon more than 25 years of DEWETRON expertise in measurement engineering. CUSTOMIZED MODULAR COMPETENT...
Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office. Support For any support please contact your local distributor first or DEWETRON directly.
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these requirements.
DO NOT substitute parts or modify equipment: Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained.
Calibration certificate according to ÖKD (equivalent to DKD) This manual contains no calibration information. For self calibration, there is a separate Calibration Manual available. DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
For internal usage only Filter connector +5 V DGND DGND n.c. +15 V Power connector RS-485 -15 V n.c. DGND RS-232 FLT (GND) 3 1 4 5 DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ series overview MDAQ Series overview Address settings If you use DEWE-ORION-16xx cards, each MDAQ Module is controlled directly via the RS-485 interface of the associated card. When using DEWE-ORION-32xx cards each card controls and converts two MDAQ modules. Set all address selectors to 0. An additional EPAD module has to be connected to the first MDAQ Module.
Page 15
A/D converter card module address PCB for CH 240 to CH 255 cross wiring Optional EPAD Modules For special wiring see DEWE-xxxx systems manual appendix B3. DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ series overview MDAQ Series overview MDAQ channel addressing Each MDAQ-V-xx module has 16 analog input channels, which can be independent configured. Since only the base address of the MDAQ-V-xx is changeable the access to the input channel configuration is in the range between (Module address x 16) to (Module address x 16) +15.
MDAQ-SUB-V-200-D only! For safety reasons max. 50 V may be applied to modules with BNC input-connectors! Refer to the regulation of maximum allowable touch potential. DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-SUB-V-200-x Internal signal processing The picture below shows the block diagram of the MDAQ-SUB-V-200-xx MDAQ-SUB-V-200-xx MDAQ-BASE-x opt. MDAQ-FILT-x TEDS TEDS CONTROL divider Differential Amplifier with Offset and 950 k IN + CMR control divider + 15 V 50 k 50 mA Sub+ Sig Out Sub-...
MDAQ-SUB-V-200-x Common mode voltage range In contrast to isolated amplifiers the input common voltage range is limited at differential amplifiers. The measurement configuration below shows the possibilities to measure the current of a 24 V supplied system. 0.1 Ω 24V Battery Load 0.1 Ω...
MDAQ-SUB-ACC Input connection The picture below shows the principal configuration of the amplifier circuit. If no filter board is installed, this field shows the analog bandwidth MDAQ-SUB-ACC MDAQ-BASE-x MDAQ-FILT-x 24 V PGA: 0.5, 1, 2, 4, 5, 10, 20 and 40; Programmable Programmable offset and common AC/DC couling...
68-pin Amplimite series (AMP Nr. 174339-6) Dimensions (W x D x H) 175 x 61 x 30 mm (6.9 x 2.4 x 1.2 in.) DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-SUB-ACC-A-BNC Input connection The picture below shows the principal configuration of the amplifier circuit. If no filter board is installed, this field shows the analog bandwidth MDAQ-SUB-ACC-A MDAQ-BASE-x MDAQ-FILT-x 24 V 8 mA AC 3.4 Hz 4 mA PGA: 0.5, 1, 2, 4, 5, 10, 20 and 40; Programmable offset 47 nF AC 0.15 Hz...
Connectors Connectors IEPE® Voltage output Sensor Measurement: IEPE Measurement: Voltage ® Pin assignment of the input connectors MDAQ-SUB-ACC-A-BNC Hot: IN + Shield: IN - DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
LED to shine ® green. The sensor check unit isn’t able to check if the sensor measures correct values! DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-SUB-ACC-A-MD Input connection The picture below shows the principal configuration of the input multiplexer and the sensor check function. To MDAQ-ACC-x amplilfier Sensor Input Input + Ref.Sig + Sensor check Input - Ref.Sig - Ref.Volt. Ctrl. Pin assignment The table below shows the pin assignment of the control connector. 1 Ref.
120 Ohm @ 15 W Standard operating temperature 0 °C to 70 °C ( 32 °F to 158 °F) MDAQ-BASE-10A has the half offset adjustment range DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-SUB-BRIDGE-D Internal signal processing MDAQ-SUB-BRIDGE MDAQ-BASE-xA MDAQ-FILT-x 50 mA +15V out (optional) Sense+ Differential Amplifier with Offset and 0 .. 7 CMR control +Uref Exc+ (0..6V) AC/DC G 1, G 50 Sub+ 1µF Sig Out Sub- G = (-1) 8 gains Exc- MDAQ-BASE-5: 0.5, 1, 2, 4, 8, 10, 20, 40...
Measurement: Voltage The table on the next page shows how the mV/Vranges are calculated. The ranges depend on the gain and the excitation voltage. DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
350 Ohm 16 Channels typ. 15 W Standard operating temperature 0 °C to 70 °C ( 32 °F to 158 °F) MDAQ-BASE-10A has the half offset adjustment range DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-SUB-STG-D Internal signal processing PROG MDAQ-SUB-STG-D Sense+ MDAQ-BASE-x MDAQ-FILT-x (optional) Exc+ Differential Amplifier with Offset and CMR control G 1, G 50 Sub+ Sig Out Sub- G = (-1) Exc- Sense- TEDS TEDS Controller...
Sense leads (SUB-D: pin 3 and 6) have to be connected! 'R+' has to be connected only if shunt calibration is required, otherwise it can be left unconnected. DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
±7.5 V to ±15 V direct via MDAQ-BASE or -V Power consumption Typ. 3 W Dimensions (W x D x H) 175 x 61 x 14 mm (6.9 x 2.4 x 0.9 in.) DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
±7.5 V to ±15 V direct via MDAQ-BASE or -V Power consumption Typ. 3 W Dimensions (W x D x H) 175 x 61 x 25 mm (6.9 x 2.4 x 1 in.) DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
MDAQ-AAF4-5-Bx Step response of 100 Hz filter Butterworth 4 order Butterworth - maximally flat in the pass band frequency response - There is some overshoot in the time domain - Butterworth rolls off faster than the Bessel filter...
EN 55011 Class B Immunity EN 61000-6-2 Group standard Graz, October 14, 2008 Dipl.-Ing. Roland Jeutter / Managing director Place / Date of the CE-marking DE-M080402E • DEWE-MDAQ series • Technical Reference Manual • Printing version 1.0.2 • January 16, 2011...
Need help?
Do you have a question about the DEWE-MDAQ Series and is the answer not in the manual?
Questions and answers