Cold Point Adirondack Aire 816 Installation, Operation & Maintenance Manual

Water source replacement unit

Advertisement

816 Slant Coil
Water Source Replacement Unit
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Cold Point Corporation, Rome, New York 13440 | Phone 315.339.2331 Fax 315.339.2358 | www.ColdPointCorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Adirondack Aire 816 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cold Point Adirondack Aire 816

  • Page 1 816 Slant Coil Water Source Replacement Unit INSTALLATION, OPERATION & MAINTENANCE MANUAL Cold Point Corporation, Rome, New York 13440 | Phone 315.339.2331 Fax 315.339.2358 | www.ColdPointCorp.com...
  • Page 2 Only auxiliary electric heaters approved by Cold Point shall be Only auxiliary electric heaters approved by Cold Point shall be who meet local, state, and federal proficiency requirements.
  • Page 3 Adirondack Aire 816 Slant Coil - IOM Attentions, Cautions, and Warnings CAUTION CAUTION CAUTION CAUTION DO NOT store or install units in corrosive environments or in DO NOT store or install units in corrosive environments or in For duct connected appliances containing A2L refrigerants, false For duct connected appliances containing A2L refrigerants, false locations subject to temperature or humidity extremes (e.g., attics,...
  • Page 4 Adirondack Aire 816 Slant Coil - IOM General Information Inspection: ordering and shipping documentation to ensure the Upon receiving your equipment, carefully check the correct unit has been delivered. shipment against the bill of lading. Make sure you have received all units. Inspect each unit and it’s 2.
  • Page 5 Adirondack Aire 816 Slant Coil - IOM General Information Presence of Fire Extinguisher: • Refrigerant piping or components are installed in In the event that hot work is to be performed on a position where they are unlikely to be exposed...
  • Page 6 Adirondack Aire 816 Slant Coil - IOM General Information Repair to intrinsically safe components: Table 1: Altitude Adjustment Intrinsically safe components must be replaced. ft (m) Cabling: 0 (0) 1.00 Ensure that the cabling is protected from wear, 656 (200) 1.00...
  • Page 7: Refrigeration System

    Adirondack Aire 816 Slant Coil - IOM Refrigerant System Servicing to avoid using compressed air or oxygen for purging The following leak detection methods are acceptable refrigerant systems. for all refrigerant systems: For appliances with flammable refrigerants, the Electronic leak detectors can be employed to purging process involves breaking the vacuum with locate refrigerant leaks;...
  • Page 8 Adirondack Aire 816 Slant Coil - IOM Refrigerant System Servicing special cylinders for the recovery of refrigerant). • All personal protective equipment is accessible Cylinders shall be complete with pressure-relief and utilized properly. valve and associated shut-off valves in good working order.
  • Page 9: Operating Limits

    Adirondack Aire 816 Slant Coil - IOM OPERATING LIMITS Minimum Model serviceable Cold Cooling Heating area (ft2) Start 816-10 11.7 Min. Ambient Air 816-12 16.6 Min. EWT Min. EWT 816-15 12.3 Max. Ambient Air 95/78 Max. EWT Normal = 3.0 Max = 4.2...
  • Page 10 Adirondack Aire 816 Slant Coil - IOM Compatibility: immediately. Any evidence of rough handling or This Adirondack-Aire model was designed to be apparent damage should be noted on the delivery direct replacements for Climate Master model ‘816’ receipt and the material inspected in the presence Slant Coil vertical stacked water source heat pump of the carrier’s representative.
  • Page 11: Warranty

    Adirondack Aire 816 Slant Coil - IOM personal injury or death the unit must be used on a grounded power supply only. 5). Adirondack-Aire 816 Slant Coil units are rated for Model Weight 208/230V power supply circuits. Unit performance and...
  • Page 12 Adirondack Aire 816 Slant Coil - IOM the return and a gate or ball valve be installed at the Pre-Start Quick Check List: supply. The return valve can be adjusted to obtain the • Before proceeding with the start-up of individual proper water flow.
  • Page 13 Adirondack Aire 816 Slant Coil - IOM WARNING: Bodily injury can result from high constant temperature. voltage electrical components. If operating checks must be performed with the unit operating, it is IMPORTANT! Wait at least 3 minutes after turning the technician’s responsibility to recognize there the air conditioner off before trying to restart it.
  • Page 14 Adirondack Aire 816 Slant Coil - IOM 4). Microbial growth can occur in water source heat 1). Disconnect all electrical power to the unit. pumps anywhere in the air stream where moisture 2). Wear the appropriate personal protective exists. ASHRAE standards 62-89 recommends equipment.
  • Page 15 Adirondack Aire 816 Slant Coil - IOM 1). Disconnect all electrical power to the unit. 14). Be careful that the contaminated material does not come into contact with other areas of her unit 2). Wear the appropriate personal protective or building. Properly dispose of all contaminated equipment.
  • Page 16 Adirondack Aire 816 Slant Coil - IOM Before Calling for Factory Assistance A call to the factory is sometimes necessary for technical support or service/troubleshooting. We are happy to help! Before calling please gather and record the following information so that we are best able to help.
  • Page 17: Troubleshooting Chart

    Adirondack Aire 816 Slant Coil - IOM TROUBLESHOOTING CHART The troubleshooting chart that follows is provided to serve as an aid for identifying malfunctions that may occur. Within the chart are three columns. 1. The Problems column describes what the unit is doing.