VT Series PTAC Replacement Chassis INSTALLATION, OPERATION & MAINTENANCE MANUAL Cold Point Corporation, Rome, New York 13440 | Phone 315.339.2331 Fax 315.339.2358 | www.ColdPointCorp.com...
Page 2
Only auxiliary electric heaters approved by Cold Point shall be Only auxiliary electric heaters approved by Cold Point shall be who meet local, state, and federal proficiency requirements.
Page 3
Adirondack Aire VT series - IOM Attentions, Cautions, and Warnings CAUTION CAUTION CAUTION CAUTION DO NOT store or install units in corrosive environments or in DO NOT store or install units in corrosive environments or in For duct connected appliances containing A2L refrigerants, false For duct connected appliances containing A2L refrigerants, false locations subject to temperature or humidity extremes (e.g., attics,...
Adirondack Aire VT series - IOM General Information Inspection: Preparation of Units for Installation: Upon receiving your equipment, carefully check the 1. Verify Unit Shipment: Confirm that the electrical shipment against the bill of lading. Make sure you specifications on the unit’s nameplate match the have received all units.
Page 5
Adirondack Aire VT series - IOM General Information intrinsically safe. • Refrigerant piping or components are installed in Presence of Fire Extinguisher: a position where they are unlikely to be exposed In the event that hot work is to be performed on...
Adirondack Aire VT series - IOM General Information Repair to intrinsically safe components: Table 1: Altitude Adjustment Intrinsically safe components must be replaced. ft (m) Cabling: 0 (0) 1.00 Ensure that the cabling is protected from wear, 656 (200) 1.00...
Adirondack Aire VT series - IOM Refrigerant System Servicing to avoid using compressed air or oxygen for purging The following leak detection methods are acceptable refrigerant systems. for all refrigerant systems: For appliances with flammable refrigerants, the Electronic leak detectors can be employed to purging process involves breaking the vacuum with locate refrigerant leaks;...
Page 8
Adirondack Aire VT series - IOM Refrigerant System Servicing special cylinders for the recovery of refrigerant). • All personal protective equipment is accessible Cylinders shall be complete with pressure-relief and utilized properly. valve and associated shut-off valves in good working order.
Adirondack Aire VT series - IOM Ambient Air Limitations Minimum OUTDOOR [Ambient air temperature °F (°C)] Model serviceable COOLING COOLING HEATING area (ft2) Minimum Maximum Maximum VT-12 25.6 Dry bulb Dry bulb Dry bulb VT-18 28.9 67 (19) 115 (46) 75 (24) INDOOR [Ambient air temperature °F (°C)]...
Page 10
Adirondack Aire VT series - IOM Dimensional Detail ‘VT’ CHASSIS 54 ½ VT Series Electric Heat Specifications Heater Min CKT Max. Volts Watts BTU / H Amps Amps Amps Fuse VT Series Cooling Only Performance Data* 14.4 15.7 19.3 Cooling...
Page 11
Adirondack Aire VT series - IOM Compatibility: Pre-installation safety instructions: These Adirondack-Aire replacement models are designed to be direct replacements for ACP/ Failure to follow these instructions can result in Climate Master ‘VT’ series. The Adirondack-Aire fire or electrical shock causing serious personal unit is dimensionally identical to the originals injury or death and property damage.
Adirondack Aire VT series - IOM The chassis is to be used only with metal wall sleeves INSTALLATION: and room cabinets. Work with a helper to avoid personal injury or property damage if the chassis is too heavy or awkward to All wiring must comply with ‘nec’...
Page 13
Adirondack Aire VT series - IOM are employed must be approved by the factory in thermostat set point to the coldest setting. The advance of replacement chassis installation. The compressor, condenser fan, and evaporator blower chassis condenser coil must align with and contact should all turn on.
Adirondack Aire VT series - IOM Set the thermostat temperature to a setting warmer than the room temperature. The compressor & than the room temperature. The compressor & condenser fan does not run during the heating cycle. condenser fan does not run during the heating cycle.
Page 15
Adirondack Aire VT series - IOM are not maintained properly. 3). Gain access to the coil section of the unit (both sides). CONDENSATE DRAINS Condensate drains can pick up lint and dirt, especially 4). Using a soft brush, remove loose debris from both with dirty filters.
Page 16
Adirondack Aire VT series - IOM Before Calling for Factory Assistance A call to the factory is sometimes necessary for technical support or service/troubleshooting. We are happy to help! Before calling please gather and record the following information so that we are best able to help.
Adirondack Aire VT series - IOM TROUBLESHOOTING CHART The troubleshooting chart that follows is provided to serve as an aid for identifying malfunctions that may occur. Within the chart are three columns. 1. The Problems column describes what the unit is doing.