Superior Fireplaces DRT3000-E Series Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Quick Links

P/N 901275-00 REV. B 08/2024
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 901275-02
P901275-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certi ed kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by
a quali ed installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRT3000-E Series Direct-Vent Gas Fireplaces
Models
DRT3035DEN-E
C
US
DRT3035DEP-E
Report No. F13-094
DRT3035DMN-E
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRT3035DMP-E
DRT3040DEN-E
DRT3040DEP-E
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides in ammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien quali é
ou par le fournisseur de gaz.
DRT3040DMN-E
DRT3045DEP-E
DRT3040DMP-E
DRT3045DMN-E
DRT3045DEN-E
DRT3045DMP-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRT3000-E Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior Fireplaces DRT3000-E Series

  • Page 1 Installation and Operation Instructions DRT3000-E Series Direct-Vent Gas Fireplaces P/N 901275-00 REV. B 08/2024 Models Ce manuel est disponible en francais, simplement DRT3035DEN-E DRT3035DMP-E DRT3040DMN-E DRT3045DEP-E en faire la demande. Numéro de la pièce 901275-02 DRT3035DEP-E DRT3040DEN-E DRT3040DMP-E DRT3045DMN-E Report No. F13-094...
  • Page 2: Safety And Your Fireplace

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 SAFETY AND YOUR FIREPLACE See attached color yer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 35” Log Set 40” / 45” Log Set THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your replace.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en...
  • Page 6: Appliance Installation, Service, And Maintenance Notices

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a quali ed installer, service agency or the gas supplier.
  • Page 7: Appliance Operation Notices

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 APPLIANCE OPERATION NOTICES These replaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Installation

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 INSTALLATION PACKAGING All models include The assembled vented gas replace heater is packaged with: • Literature Kit (bag in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Btu Input

    Innovative Hearth Products General Information DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 35” Models 20.000 15,000 17,000 14,000 40”...
  • Page 10 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sections 4.00 through 8.00.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 6” minimum Mantel depth side wall clearance, 16 (407) Top View of a combustible wall Fireplace can project to any length.
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 18 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 10 - Fireplace Framing Speci cations Model Framing NOTE: Dimension “D” is the construction to be 10-1/2 35-7/8 36-1/4 38-3/4 18-1/2 23-3/8 required framing depth when 2 x 4, or larger.
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the replace cabinet are shipped at. Remove the screw adjacent to the detached end (Figure 7A).
  • Page 20: Installing Non-Combustible Front Fireboard Standoff And Header Shield

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing Non-Combustible Front Fireboard Standoff and Header Shield A non-combustible standoff board is provided with the replace to prevent overlap of drywall or other material of portions of the replace that may be prone to the buildup of heat.
  • Page 21 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 9A Figure 9D Install Vent Cover Plates after connecting the Vent Insulation Piece 1 Insulation Piece 2 Vent Cover Plates Outer Rear Flue Cover Insulation Piece 2 Insulation Piece 1...
  • Page 22: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Rough in the Electrical Supply, if Needed As necessary, rough in the replace electrical supply per NEC and local codes. Place the Fireplace in the Framing and Secure NOTE: Nailing anges, combustible members, and screw heads in areas directly adjacent to the nailing anges are EXEMPT from the 1/2”...
  • Page 23: Vent System Preparation

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 VENT SYSTEM PREPARATION Select a Horizontal or Vertical Vent System 1. With the replace secured in the framing, determine the vent route and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved vent components.
  • Page 24: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 12 and 13B.
  • Page 25 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Connecting the Vent Pipe Secure Vent ® SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist lock connections (Figures 15 - 16). All of the replaces covered in this document are tted with collars having locking inclined channels.
  • Page 26 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Elbow/Wall Heat Shield If using a 90 degree rigid elbow or ex venting directly off top of replace, an Elbow Heat Shield is required. Install per instructions in Figure 17.
  • Page 27 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent con guration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter.
  • Page 28: Clearance To Combustibles

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, • 1” (26 mm) from all sides attic, ceiling insulation, etc.). For all vertical runs: • 3” (77 mm) from the top NOTE: Attic insulation shield (H3907, see Page 52) must be •...
  • Page 29 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 25 and 27 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 30 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 25 for more information.
  • Page 31 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Vertical Vent Figures/Tables NOTE: Secure Vent ® rigid vent pipe is shown in the gures; Secure Flex ® exible vent pipe may also be used. NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 32 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex ® , use ceiling restop/ Ceiling restop/ spacer SF4.5VF.
  • Page 33 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the...
  • Page 34 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 25 Figure 25A Bent inserted tabs Slots Two (2) outside tabs 90 degree bent Center tab Center tab 9. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections.
  • Page 35 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 26 - Installing the Horizontal Termination Installing the Horizontal Termination, SV4.5HT-2 To help minimize water in ltration Firestop/Spacer (SV4.5HF) shown Typical (all models) or SV4.5HTSS (35” models only)
  • Page 36 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 37 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Min. One...
  • Page 38 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall restop/spacer 1.524 0.610 0.305 Wall Firestop/Spacer SV4.5HF ** SV4.5HF**...
  • Page 39 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 ® Vertical or Horizontal Venting Using Secure Flex Kits and Components When Secure Flex ® kits are used in a rear ue, horizontal termination installation, at least 1 ft of vertical rise is required.
  • Page 40: Complete The Field Wiring

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 f. Install three (3) sheet metal screws 120° apart through the exible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection.
  • Page 41 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 1. If installing an ON/OFF wall switch or thermostat, mount it in a convenient location on a wall near the replace. 2. Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with the unit (Figure 28).
  • Page 42 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 See the Operation section on Page 54 for more details. NOTE: Electronic models must be connected to the main power supply. 1. Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the replace junction box.
  • Page 43: Connect The Gas Line

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Connect the Gas Line All codes require a shutoff valve mounted in the supply line. Figure 31 illustrates two methods for connecting the gas supply. The ex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality.
  • Page 44: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Test Factory and Field Connections for Gas Leaks WARNING Never use an open ame to check for leaks. Turn on gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution.
  • Page 45: Optional Accessory: Install The Firebox Liners

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Install the Firebox Liners (Optional Kits) 1. Install the Firebox Liners (see Page 57). Install the Logs, and Glowing Embers 1. See Pages 59 - 65 for instructions on Installing the logs, and glowing embers.
  • Page 46 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 33 - Air Shutter Adjustment Rod Table 28 - Air Shutter Adjustment Guidelines Adjustment Amount of Primary Air Flame Color Air Shutter Adjustment Set-Screw If air shutter is...
  • Page 47: Install The Hood

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Install the Hood after replace is cool NOTE: All models must have a hood installed prior to operation, and is provided with required facade. NOTE: Hood is slotted and has some adjustment. It is suggested that the center screw should be installed rst and the ends last.
  • Page 48: Required Accessory: Facade Installation And Barrier Replacement

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 36B - Facade Installation Facades NOTE: A Facade / Barrier shall be purchased separately and installed prior to operation (see Page 49). Facade (with barrier) Vista Frame Install the Facade (with barrier).
  • Page 49: Install The Finishing Materials

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Figure 36E - Bend Retaining TAB UP Barrier Assembly Replacement (Craftsman and Re ection) - See Figure 36D through 36F If the screen mesh barrier gets damaged it shall be replaced prior Retaining Tab to operation of the replace.
  • Page 50: Installer - Attaching Safety-In-Operation Warnings

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly af xed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 51: Installation Accessories

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent ®...
  • Page 52 Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Listed Secure Vent ® Components Cat. No. Model Description Cat. No. Model Description 96K93 SV4.5SU Support Strap 77L76 SV4.5E45 45° Elbow, Corrugated Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 750146M) Horizontal Riser Kit, 36”...
  • Page 53: Gas Conversion Kits

    Innovative Hearth Products Installation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a quali ed service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a re, explosion, or the production of carbon monoxide may result;...
  • Page 54: Operation

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 55 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN...
  • Page 56: Burn-In Period

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Burn-in Period The rst few times this replace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 57: Tools / Supplies Needed

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the Firebox Liners (Optional Kit) KIT CONTENTS Affected Fireplace Models 1 ea. Set of 4 Hand Bend Brackets 35" , 40" and 45" direct- 1 ea. Set of Optional Fiber Panels vent replace models offered with 1 ea.
  • Page 58 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Bracket Bracket Figure 39C - Insert Bent Bracket Bracket Example of Pre-Bent Bracket Before Insertion Insert Top Leg Of Bracket Between Lintel And Top Panel Bottom Figure 39D Figure 39F - Brackets Installed...
  • Page 59 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Install the Logs and Glowing Embers WARNING • Turn OFF all gas and electricity to the appliance before installing the embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been con rmed.
  • Page 60 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 35 Series Log Set The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between ame peaks, so they do not impinge the ames. Follow the log placement instructions precisely.
  • Page 61 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 35 Series Log Set (continued) 3. Place rear log (1) on the tab (b) on the right and rotate log until it contacts the left tab (a).(Figures 40 and 42).
  • Page 62 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 40 Series Log Set The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between ame peaks, so they do not impinge the ames. Follow the log placement instructions precisely.
  • Page 63 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 40 Series Log Set (continued) 4. Place the bottom left log (2) on to the left oor tab (a) (Figures 47 and 49). 5. Place the Middle Ember Log(3) on to the two small tabs (c & d) on the burner with the small side pointing to the left (Figure 50).
  • Page 64 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 45 Series Log Set The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between ame peaks, so they do not impinge the ames. Follow the log placement instructions precisely.
  • Page 65 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the DRT3000-E 45 Series Log Set (continued) 4. Place the Bottom Left Log (2) on to the left oor tab (a). (Figures 55 and 57). 5. Place the Middle Ember Log (3) on to the two small tabs (c & d) on the burner with the small side pointing to the left. (Figure 58).
  • Page 66: Installing And Removing The Glass Door

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 67 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated rmly. Ensure it is properly located.
  • Page 68: Maintenance

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 MAINTENANCE Refer to the Maintenance Schedule on Page 70 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper replace operation after servicing.
  • Page 69 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated rmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 70: Maintenance Schedule

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and...
  • Page 71: Accessory Components

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 ACCESSORY COMPONENTS Firebox Liner Kits Termination Shroud ( ts H1968) Bag of Glowing Embers Replacement ember materials are available for use with these appliances. Order kits Blackstone as part of the periodic maintenance of the appliance.
  • Page 72 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 Cost Effective Solution Unit-Mountable Rocker Switch Kit Thermostatic or Manual modes • Simple On/Off operation This rocker switch kit can be installed directly • LCD Display • Works with millivolt and low voltage electronic in the control compartment to provide ON/OFF •...
  • Page 73 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 ACCESSORY COMPONENTS (continued) Facade Kits (Required Option) Cat. No. Model Description Used on F5025 FVFBK35T Facade - Vista Black, 35 Trad F3570 FRBK35T Facade - Re ection, Black 35 Trad 35”...
  • Page 74: Lighting Instructions

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 75 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 76: For Your Safety Read Before Operating

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 LIGHTING INSTRUCTIONS, ELECTRONIC - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 77 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 LIGHTING INSTRUCTIONS, ELECTRONIC - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 78: Troubleshooting

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 TROUBLESHOOTING Before troubleshooting, ensure that the replace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the replace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 79 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 TROUBLESHOOTING Before troubleshooting, ensure that the replace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the replace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 80: Replacement Parts

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 REPLACEMENT PARTS Cat. No. Fireplace Models Description F4995 DRT3035DEN-E 35” DV Elec, NG F4996 DRT3035DEP-E 35” DV Elec, LP F4993 DRT3035DMN-E 35” DV MV, NG F4994 DRT3035DMP-E 35” DV MV, LP...
  • Page 81: Burner Orifices

    Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 35” Models 40” Models 45” Models REPLACEMENT PARTS (continued) Cat. No. Cat. No. Cat. No. Millivolt Parts --- Millivolt Pilot Assembly, Natural Gas 69L17 69L17 69L17 --- Millivolt Pilot Assembly, Liquid Propane...
  • Page 82 Innovative Hearth Products Operation DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 83: Warranty

    Innovative Hearth Products Superior ® Brand Gas Fireplaces, Stoves and Inserts 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior ® Brand gas replace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture.
  • Page 84 Innovative Hearth Products Installation and Operation Instructions DRT3000-E Series Direct-Vent Gas Fireplaces 901275-00B, 08/2024 SuperiorFireplaces.us.com Record the following important information about your replace: Fireplace model number Fireplace serial number Date replace was Installed Type of gas replace uses Dealer name...

Table of Contents