  • Page 1 INSTRUKCJA OBSŁUGI Rekuperatorów HRU-SlimAIR-P -250/-300/-350/-400/-500/-800/-1000 USER MANUAL Heat and energy recovery ventilators HRU-SlimAIR-P -250/-300/-350/-400/-500/-800/-1000 wersja / ver. 0924...
  • Page 2: Table Of Contents

    11. Tryb kominka 12. Alarmy 13. Komunikacja Modbus 14. Aplikacja 15. Utylizacja 16. Rozwiązania problemów 17. Klasa energetyczna 18. Deklaracja zgodności Warunki gwarancji rekuperatora Karta gwarancyjna ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 3: Instrukcja Obsługi

    Przy pomocy panelu HRQ-BUT-PG15 lub wyświetlacza można ręcznie nastawiać jedną z prędkości wentylatorów (AWAY,HOME,HOME+). Jeśli urządzenie wyposażone jest w panel HRQ-BUT-PG15 oraz aktywne połączenie internetowe, można nastawiać te trzy prędkości poprzez aplikację mobilną lub domenę www.air.alnor.com.pl. Jeśli dodatkowo zamontowano czujniki CO i wilgotności względnej, prędkość można kontrolować automatycznie w zależności od stężenia CO...
  • Page 4: Bezpieczeństwo

    6. Filtry: ISO Coarse 70% (G4), opcjonalnie ISO ePM1 55% (F7) 7. Nagrzewnica wstępna: wbudowana (opcja) 8. Montaż: pionowy, poziomy, podwieszany poziomy - nie każda jednostka ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 5 Rys. 2 – Spadki ciśnienia dla HRU-SlimAIR-250-H-P Rys. 3 – Spadki ciśnienia dla HRU-SlimAIR-250E-H-P HRU-SlimAIR-250E 250m /h (przy 100 Pa) HRU-SlimAIR-250 ® ALNOR systemy wentylacji 250m /h (przy 100 Pa) jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 6 Przepływ powietrza [m Przepływ powietrza [m – – Rys. 8 Spadki ciśnienia dla HRU-SlimAIR-400-P Rys. 9 Spadki ciśnienia dla HRU-SlimAIR-400E-P przepływ  [m3/h] ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 7 Przepływ powietrza [m Przepływ powietrza [m3/h] Przepływ powietrza [m3/h] Przepływ powietrza [m – – Rys. 14 Spadki ciśnienia dla HRU-SlimAIR-1000-H-P Rys. 15 Spadki ciśnienia dla HRU-SlimAIR-1000E-H-P ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 8 Data Zatwierdzony przez Data Marcin Lipka 09.11.2020 Nazwa części Skala schemat budowy SlimAIR 1 : 10 Materiał Masa Format Rys. 16 – Schemat budowy dotyczy ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 9 Instrukcja obsługi HRU-SlimAIR 13. Schemat płyty gównej: ~230V ~230V Rys. 17 – Schemat płyty głównej ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 10 DIN), alarm SAP, progowe czujniki CO2,RH, PPM, temperatury Gruntowy wymiennik ciepła (opcja-nagrzewnica wtórna ON-OFF, OUT1 chłodnica wtórna ON-OFF) Nagrzewnica wtórna ON-OFF, chłodnica wtórna ON-OFF OUT3A ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 11: Instalacja

    • karton z nadrukowanym schematem stelażu (po wewnętrznej stronie pokrywy pudełka). Rys. 18 – Rozpakowanie centrali wentylacyjnej Zaprojektowany przez Data Sprawd Marcin Lipka 07.06.2022 Nazwa c Karto ® ALNOR systemy wentylacji Materia jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 12: Montaż Jednostki Pionowy

    SlimAIR-800-P 1465 SlimAIR-1000-P 1465 WYMIAR HRU-SlimAIR-250 HRU-SlimAIR-350 1117 1231 – Rys. 20 Wymiary otworów pod standardowe elementy mocujące ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone. Zaprojektowany przez Data Sprawdzony przez Data Zatwierdz...
  • Page 13: Montaż Jednostki Poziomy

    Zatwierdzony przez Kacper.Szykuła 25.02.2021 Nazwa części Skala montaż uniwersalny SlimAIR bez odsunięcia 1 : 10 Masa Format Materiał dotyczy – Rys. 22 Montaż jednostki poziomy ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 14: Montaż Jednostki Podwieszany

    HRQ-SlimAIR-HANG 1179 WYMIAR HRU-SlimAIR-250 HRU-SlimAIR-350 HRQ-SlimAIR-350-HANG 1283 1179 1283 HRQ-SlimAIR-500-HANG 1404 – Rys. 24 Montaż jednostki podwieszany na stelażu montażowym ® ALNOR systemy wentylacji Data Zaprojektowany przez Kacper.Szykuła 25.02.2021 jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 15 (niezależnie od rodzaju montażu) o max. 3° będzie miało pozytywny wpływ na usuwanie kondensatu z urządzenia. W przypadku braku miejsca na syfon odpływu skroplin zaleca się dokupienie pompki skroplin, którą można nabyć w hurtowniach HVAC. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 16: Instalacja Kanałów

    (np. kolanka, odsadzki, itp.). Złączka NSL jest montowana zatrzaskowo, a celem demontażu należy ściągnąć je przy użyciu odpowiedniej siły. Zastępcze złącza podłączone do centrali muszą mieć zakończenia nyplowe zgodnie z normami wymiarów firmy ALNOR (sprawdź tolerancje wymiarów w naszym katalogu systemu SPIRAL®). Aby zapewnić najlepszą szczelność, zalecamy stosowanie produktów firmy ALNOR z uszczelką.
  • Page 17: Rozruch

    Nawet, gdy dom jest pusty i brak jest czy wytwarzania wilgoci przez ludzi, i tak wszelkie materiały konstrukcyjne emitują liczne zanieczyszczenia. Zalecamy nastawianie prędkości na niską na czas nieobecności w domu. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 18: Pomiar Temperatury

    Tryb antyzamarzania zostanie wyłączony, gdy temperatura na wyrzutni (T ) osiągnie temperaturę wyższą niż skonfigurowaną temperaturę włączenia trybu antyzamarzania (T )+ histereza wyłączenia antyzamarzania (H >T ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 19: Nagrzewnice Wstępne

    Rysunek 28 przedstawia przykład podłączenia nagrzewnicy. Doradzamy założenie przed nagrzewnicą filtra, aby przeciwdziałać zabrudzeniu grzałek i przedłużyć eksploatację produktu. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 20 Zaprojektowany przez Sprawdzony przez Zatwierdzony przez Data Data Rys. 28 – Podłączenie nagrzewnicy wodnej przemyslaw.goworek 12.12.2023 ® Wydanie Arkusz Slimer_domeK 1 / 1 ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 21: Bypass

    • Bypass otwarty – niezależnie od warunków zawór bypass pozostaje otwarty • Bypass zamknięty – niezależnie od warunków zawór bypass pozostanie zamknięty • Auto – zawór bypass będzie sterowany według odpowiedniego algorytmu działania ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 22: Ogrzewanie Bierne

    1m. Istnieje możliwość wyprowadzenia zewnętrznego czujnika temperatury powietrza HRQ-SENS-500, który powinien być zamontowany w kanale nawiewnym za nagrzewnicą/chłodnicą. Dzięki temu możemy monitorować rzeczywistą temperaturę nawiewu za nagrzewnicą/chłodnicą. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 23: Podpięcie Wtórnej Nagrzewnicy, Chłodnicy Lub Nagrzewnico/Chłodnicy Wodnej

    Zasilane 230VAC Belimo TRY230 2Nm HDW-200 R3015-1P6-B1 (DN15, kvs-1,6) Zasilane 230VAC Aby układ działał prawidłowo należy podpiąć zawór z siłownikiem elektrycznym do złącza OUT1 w kolejności: ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 24 (w stronę otwarcia drożności A –> AB). Następnie należy dokonać zmian w płycie sterującej zgodnie z poniższą instrukcją: (zmian można dokonać z poziomu wyświetlacza HRQ-BUT-LCD, aplikacji AlnorAIR, lub domeny). ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 25: Podpięcie Wtórnej Nagrzewnicy Elektrycznej

    Termostat nagrzewnicy wtórnej musi zostać aktywowany w celu ochrony przed przegrzaniem poprzez zablokowanie pracy nagrzewnicy. W przypadku wielokrotnego zadziałania termostatu nagrzewnicy elektrycznej ( co najmniej 3 razy w ciągu ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 26: Ochrona Temperatury Nawiewu

    ) (domyślnie 3°C) Włączenie ochrony przed zbyt niską temperaturą nawiewu < T przez okres nawiew pgn Wyłączenie ochrony przed zbyt niską temperaturą nawiewu > T nawiew pgw ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 27: Filtry Powietrza

    Rys. 31 – Wymiana filtrów Data Data Data Zaprojektowany przez Sprawdzony przez Zatwierdzony przez Kacper.Szykuła 09.11.2020 Nazwa części Skala montaż filtrów powietrza 0,13 : Materiał Masa Format dotyczy ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 28: Czyszczenie Wymiennika Ciepła

    2 x śruba torx M4 zabezpieczenie wymiennika zabezpieczenie wymiennika Zaprojektowany przez Data Kacper.Szykuła 09.11.2020 Zaprojektowany przez Data Kacper.Szykuła 09.11.2020 Rys. 32 – Wymiana wymiennika ciepła ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 29: Podpięcie Gruntownego Wymiennika Ciepła

    (DATVTML). Przepustnice napędzane są siłownikiem elektrycznym DM-ML-06-230. Do szybkiego montażu siłowników polecamy specjalnie zaprojektowane podstawki DA-SUP-S oraz DA-SUP-M. Pasujące siłowniki do DA-SUP-S Pasujące siłowniki do DA-SUP-M DA4MU24-D/DS Alnor DM-ML-06 Alnor DM-ML-06 General Damper Actuator DA4MU230-D/DS 4Nm 6Nm Belimo CM...
  • Page 30: Podpięcie Przełącznika Sterowania / Okapu

    W tym celu wykorzystujemy wejścia DIN 2 oraz DIN 3. Możliwe jest równoległe podłączenie wielu przełączników, aby móc sterować z różnych pomieszczeń. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 31: Tryb Kominka

    11. Tryb kominka Tryb kominka jest trybem czasowym do którego mamy dostęp z poziomu aplikacji mobilnej oraz serwisu Air.Alnor.com.pl. Pozwala on na czasowe wysterowanie wentylatora wyciągowego poprzez ustalenie zadanej różnicy w stosunku do wentylatora nawiewnego. 12. Alarmy Praca w stanie awaryjnym dozwolona jest wyłącznie pod nadzorem użytkownika do czasu przyjazdu serwisu i usunięcia usterki.
  • Page 32 ALARM aktywne, procedura elektrycznej wtórnej - termostatu. Zbyt niski momentu odnotowania cyklicznego alarmu 3x zadziałanie przepływ powietrza, termostat przyczyny. nagrzewnicy elektrycznej. termostatu. nagrzewnicy może wymagać potwierdzenia alarmu. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 33 Sygnalizacja alarmu, wyjście akceptacji alarmu nawiewu. Wyłącz wyłączyć centralę wentylacyjną ALARM aktywne. następuje przejście do centralę i wymień filtr. i wymienić odpowiedni filtr. procedury wymiany filtrów. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 34 Podłączony czujnik ecoPRESS Błąd wewnętrzny Nieustannie po został uszkodzony bądź błędnie czujnika ecoPRESS Sygnalizacja alarmu. odnotowaniu skonfigurowany (każdy czujnik 1 – 4 przyczyny. generuje osobny alarm). ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 35: Komunikacja Modbus

    • polecenia (1 bajt, w przypadku polecenia odczytu – 0x03) • numeru pierwszego z odczytywanych rejestrów (2 bajty) • liczby odczytywanych rejestrów (2 bajty); CRC (2 bajty) ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 36 • liczby modyfikowanych rejestrów (2 bajty) • liczby modyfikowanych bajtów (2x liczba modyfikowanych rejestrów) • wartość do ustawienia (2 bajty) w rejestrze 1, 2, … • CRC (2 bajty). ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 37 1 – czujnik nawiewu, 2 – czujnik panelu Temperatura Tmain -40.0 60.0 nawiewu (T2) Temperatura Tsup -40.0 60.0 wywiewu (T3) Temperatura czerpni/ Texh -40.0 60.0 zewnętrzna (T4) ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 38 % control wtórnej (N2) Wysterowanie integer wysterowanie w % control chłodnicy (CH1) Siłownik gruntowego 0 – nieaktywne, integer wymiennika 1 – aktywne ciepła ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 39 °C wtórna (N2) Wysterowanie Temp_USER 4 nagrzewnicy integer jednostka: °C wtórnej (N2) Wysterowanie wysterowanie integer chłodnicy (CH1) Wentylator wysterowanie wywiewny, integer aktualne wysterowanie ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 40 Speed_W2_ Prędkość W2 dyn. dyn. wysterowanie integer w trybie ECO (25) (100) DATE_day Dzień miesiąca integer DATE_ Miesiąc integer month DATE_year integer TIME_hour Godzina integer ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 41 UID - znaki 11 i 12 12336 23130 ASCII UID7 UID - znaki 13 i 14 12336 23130 ASCII UID8 UID - znaki 15 i 16 12336 23130 ASCII ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 42 _USER1 Pressure_ UID - znaki 5 i 6 4000 integer jednostka: Pa _USER2 Pressure_ UID - znaki 7 i 8 4000 integer jednostka: Pa _USER3 ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 43 Pa analogowy 0 – nieaktywna, SAP_AL Alarm SAP integer 1 – aktywna Wymagany 0 – nieaktywna, Service_AL integer przegląd ogólny 1 – aktywna ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 44 Przegrzanie nagrzewnicy 0 – nieaktywna, N2_HT_AL integer elektrycznej 1 – aktywna wtórnej Uruchomienie wygrzewania 0 – nieaktywna, Frost_AL integer nagrzewnicy 1 – aktywna wtórnej ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 45: Aplikacja

    Producenci i importerzy spełniają swój obowiązek recyklingu, przetwarzania i zgodnej ze środowiskiem utylizacji bezpośrednio, albo uczestnicząc w programach zbiorowych. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 46: Rozwiązania Problemów

    Syfon jest pusty w rozdziale 4.2 Chłodzenie pasywne nie oznacza klimatyzacji (aktywnego chłodzenia). Aby Chłodzenie pasywne jest niewystarczające zwiększyć pasywną chłodzenia zwiększ prędkość pracy wentylatorów. ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 47: Klasa Energetyczna

    HRU-SlimAIR-300E-H-CF-P HRU-SlimAIR-350-H-P HRU-SlimAIR-350-H-CF-P HRU-SlimAIR-350E-H-P HRU-SlimAIR-350E-H-CF-P HRU-SlimAIR-400-H-P HRU-SlimAIR-400-H-CF-P HRU-SlimAIR-400E-H-P HRU-SlimAIR-400E-H-CF-P HRU-SlimAIR-500-H-P HRU-SlimAIR-500-H-CF-P HRU-SlimAIR-500E-H-P HRU-SlimAIR-500E-H-CF-P HRU-SlimAIR-800-H-P HRU-SlimAIR-800-H-CF-P HRU-SlimAIR-800E-H-P HRU-SlimAIR-800E-H-CF-P HRU-SlimAIR-1000-P 1000 HRU-SlimAIR-1000-CF-P 1000 HRU-SlimAIR-1000E-P 1000 HRU-SlimAIR-1000E-CF-P 1000 ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 48: Deklaracja Zgodności

    Deklaracja ta jest podstawą oznaczania wyrobu znakiem przeprowadzone testy i badania. Deklaracja ta jest podstawą oznaczania wyrobu znakiem Alnor Systemy Wentylacji Sp. z o.o. Alnor Systemy Wentylacji Sp. z o.o. POLSKA 05-552 Wola Mrokowska, Aleja Krakowska 10 POLSKA 05-552 Wola Mrokowska, Aleja Krakowska 10 Tel.: + 48 22 737 40 00...
  • Page 49: English Version

    11. Fireplace mode 12. Alarms 13. Modbus communication 14. App 15. Disposal 16. Troubleshooting 17. Energy rating 18. Declaration of conformity Recuperator warranty conditions Warranty Certificate ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 50: Information On Instructions

    Using the HRQ-BUT-PG15 panel or the display, one of the fan speeds (AWAY,HOME,HOME+) can be set manually. If the unit is equipped with the HRQ-BUT-PG15 panel and an active internet connection, the three speeds can be set via the mobile app or the www.air.alnor.com.pl domain. If CO and relative humidity sensors are additionally fitted, the speed can be controlled automatically depending on the CO concentration and relative humidity level (activate auto mode).
  • Page 51: Safety

    6. Filters: ISO Coarse 70% / ISO ePM1 55% (optional) 7.Pre-heatear: built-in (option) 8. Instalation: vertical, horizontal, overhead horizontal - not every unit ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 52 Fig. 2 - Pressure drops for HRU-SlimAIR-250-H-P Fig. 3 - Pressure drops for HRU-SlimAIR-250E-H-P HRU-SlimAIR-250E 250m /h (przy 100 Pa) HRU-SlimAIR-250 ® 250m /h (przy 100 Pa) ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 53 Air flow [m Air flow [m – – Rys. 8 Pressure drops for HRU-SlimAIR-400-H-P Rys. 9 Pressure drops for HRU-SlimAIR-400E-H-P przepływ  [m3/h] ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 54 Przepływ powietrza [m3/h] Przepływ powietrza [m3/h] Air flow [m Air flow [m – – Rys. 14 Pressure drops for HRU-SlimAIR-1000-P Rys. 15 Pressure drops for HRU-SlimAIR-1000E-P ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 55 Data Zatwierdzony przez Data Marcin Lipka 09.11.2020 Nazwa części Skala schemat budowy SlimAIR 1 : 10 Fig. 16 - Construction diagram Materiał Masa Format dotyczy ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 56 User manual HRU-SlimAIR 13. Diagram of the main board (PCB): Fig. 17 - Main board diagram ~230V ~230V ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 57 Preheater thermostat, control panel, canopy mode (needs 2 DIN inputs), SAP DIN5 alarm, threshold sensors for CO2, RH, PPM, temperature Ground heat exchanger (option: ON-OFF Preheater, OUT1 after-cooler ON-OFF) Preheater ON-OFF, secondary cooler ON-OFF OUT3A ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 58: Installation

    • cardboard box with printed frame diagram (on the inside of the box lid). Fig. 18 - Unpacking the air handling unit Zaprojektowany przez Data Marcin Lipka 07.06.2022 ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 59: Vertical Unit Installation

    WYMIAR HRU-SlimAIR-250 HRU-SlimAIR-350 SlimAIR-1000-P 1465 1117 1231 Fig. 20 – Dimensions of openings for standard mounts ® ALNOR ventilation systems Data Data Zaprojektowany przez Sprawdzony przez Zatwierdzony prze is a legally protected trademark and technical patent. All rights reserved. Kacper.Szykuła 25.02.2021...
  • Page 60: Horizontal Unit Installation

    Zatwierdzony przez Data Kacper.Szykuła 25.02.2021 Skala Nazwa części montaż uniwersalny SlimAIR bez odsunięcia 1 : 10 Materiał Masa Format dotyczy Fig. 22 – Horizontal unit installation ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 61: Suspended Unit Installation

    HRU-SlimAIR-350 HRQ-SlimAIR-350-HANG 1283 1179 1283 HRQ-SlimAIR-500-HANG 1404 Fig. 24 – Unit horizontally suspended on the installation frame ® ALNOR ventilation systems Data Zaprojektowany przez Sprawd Kacper.Szykuła 25.02.2021 is a legally protected trademark and technical patent. All rights reserved. Nazwa Materia...
  • Page 62 If there is no space for a condensate drain trap, it is recommended to purchase a condensate pump, which can be purchased from HVAC wholesalers. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 63: Channel Installation

    Replacement connectors connected to the control unit must have nipple ends according to ALNOR’s dimensional standards (check dimensional tolerances in our SPIRAL® system catalogue). To ensure the best seal, we recommend using ALNOR products with a gasket. We are not responsible for leakage if couplings are purchased from other companies.
  • Page 64: Start-Up

    We recommend setting the speed to low for times when you are away from home. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 65: Temperature Measurement

    The anti-freeze mode will be deactivated when the temperature at the outlet (T ) reaches a tempera- ture higher than the configured anti-freeze mode activation temperature (T )+ deactivation hysteresis antifreeze (H >T ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 66: Preheaters

    It consists in stopping the operation of the control panel and signalling the occurrence of a fault in the Alarms menu. The procedure can be deactivated by the user acknowledging the alarm. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 67: Outdoor Preheaters

    Along with the installation of the CHDW-G-200/CHDW-G-250 water preheater, it is recommended to remove the filter on the intake duct in the device. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 68 The heater is controlled by sending a signal to the pump responsible for circulating the medium. Slimer_domeK 1 / 1 The pump is powered directly from the recuperator motherboard. WAGO N WAGO PE WAGO N WAGO PE ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 69: Bypass

    Bypass operation is possible if the condition of no active winter control mode and the following conditions are met: 1. passive heating < T supply comfort ≥ T intake supply 2. passive cooling > T supply comfort ≤ T intake supply ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 70: Connecting The Post Heater, Post Cooler, Post Cooler With Heating Option

    Heat recovery unit controls the valve based on the readings of extraction temperature inside the rooms and comfort temperature, according to the formula: • Post heating: Extraction temperature < Comfort temperature -2 • Post cooling: Extraction temperature > Comfort temperature +2 ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 71: Connecting The Water Post Heater, Post Cooler, Post Cooler With Heating Option

    The three-way valve should be manually set in a position that allows liquid flow only in the B -> AB direction (diagram above). ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 72: Connecting The Electric Post Heater

    • Duct diameter 200 mm - HRQ-P-HDE-200-1.0 After connecting the wires, make changes to the control plate according to the following manual: (changes can be made from app AlnorAIR, or Alnor web) 6.6.3 Post heating/cooling PCB update Attention! Making changes to the device settings should be carried out by a qualified person. Making unsuggested changes may lead to improper operation of the device.
  • Page 73: Supply Air Temperature Protection

    Activation of protection against excessively high supply air temperature temperatures > T pgw supply Deactivation of protection against too high supply air temperature < T pgw supply ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 74: Protection Against Too Low Supply Air Temperature

    NOTE: Remember that additional filters may affect a major decrease of the pressure throughout the ventilation system. Fig. 31 - Changing the filters ® ALNOR ventilation systems Data Data Zaprojektowany przez Sprawdzony przez Zatwierdzony przez Kacper.Szykuła 09.11.2020 is a legally protected trademark and technical patent. All rights reserved.
  • Page 75: Cleaning The Heat Exchanger

    Zaprojektowany przez Data Kacper.Szykuła 09.11.2020 Zaprojektowany przez Data Sprawdzony przez Kacper.Szykuła 09.11.2020 Nazwa części SlimAIR - wy Materiał Fig. 32 - Heat exchanger replacement ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 76: Connection Of The Ground Heat Exchanger

    (DATVTML) must be installed. The dampers are driven by an electric actuator DM-ML-06-230. For quick mounting of the actuators, we recommend the specially designed DA-SUP-S and DA-SUP-M stands. Matching actuators for DA-SUP-S Matching actuators for DA-SUP-M DA4MU24-D/DS Alnor DM-ML-06 Alnor DM-ML-06 General Damper Actuator DA4MU230-D/DS 4Nm 6Nm...
  • Page 77: Connecting Control Switch / Kitchen Hood

    For this purpose, we use DIN 2 and DIN 3 inputs. It is possible to connect multiple control switches in parallel to control from different rooms. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 78: Fireplace Mode

    11. Fireplace mode Fireplace mode is a timed mode that can be accessed from the mobile application and Air.Alnor.com.pl website. It allows temporary control of the exhaust fan by setting a preset difference from the supply fan.
  • Page 79 ALARM active, electric heater moment of recording tripped. to have tripped. It may need to the cause alarm procedure. be reset. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 80 ALARM active. accepted, the filter replace the filter. replace the corresponding filter. replacement procedure proceeds. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 81 Internal error of sensor sensor has been damaged or Signalling of alarm. moment of recording ecoPRESS 1 - 4 misconfigured (each sensor the cause generates a separate alarm). ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 82: Modbus Communication

    • commands (1 byte, in the case of a read command - 0x03) • The number of the first register to be read (2 bytes) • number of registers read (2 bytes); CRC (2 bytes) ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 83 • The number of bytes to be modified (2x the number of modified registers) • The value to set (2 bytes) in register 1, 2, etc. • CRC (2 bytes). ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 84: Modbus Table

    - supply sensor, 2 - panel sensor Air supply Tmain temperature -40.0 60.0 (T2) Exhaust Tsup temperature -40.0 60.0 (T3) Intake/outlet Texh temperature -40.0 60.0 (T4) ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 85 (N2) Radiator control Y1 control integer steering in % (CH1) Ground Ground heat 0 - inactive, Heat exchanger integer 1 - active Exchanger actuator ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 86 % (CH1) Exhaust fan, integer steering in % current control Permission to 0 - inactive, W1_EN operate supply integer 1 - active fan (W1) ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 87 ECO mode (25) (100) DATE_day Day of the month integer DATE_ Month integer month DATE_year Year integer TIME_hour Time integer TIME_ Minute integer minutes ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 88 23130 ASCII 5 and 6 UID – characters UID4 12336 23130 ASCII 7 and 8 UID – characters 9 UID5 12336 23130 ASCII and 10 ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 89 4000 integer unit: Pa with BMS _USER2 Pressure_ 4000 integer unit: Pa _USER3 Pressure_ UID – characters 4000 integer unit: Pa 1 and 2 _USER4 ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 90 Starting level dyn. dyn. PSA_W2 integer steering in % of the exhaust fan (25) (100) Max. supply maxPres_AI pressure - 4000 integer unit: Pa analogue sensor ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 91 1 - active Electric reheater 0 - inactive, N2_HT_AL integer overheating 1 - active Start-up of 0 - inactive, Frost_AL integer reheater heating 1 - active ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 92: App

    Manufacturers and importers meet their obligation to recycle, treat and dispose of in an environmentally compatible manner either directly or by participating in collective schemes. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 93: Troubleshooting

    4.2 Passive cooling does not mean air Passive cooling is insufficient conditioning (active cooling). To increase passive cooling, increase the fan speed. ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 94: Energy Rating

    HRU-SlimAIR-300E-H-CF-P HRU-SlimAIR-350-H-P HRU-SlimAIR-350-H-CF-P HRU-SlimAIR-350E-H-P HRU-SlimAIR-350E-H-CF-P HRU-SlimAIR-400-H-P HRU-SlimAIR-400-H-CF-P HRU-SlimAIR-400E-H-P HRU-SlimAIR-400E-H-CF-P HRU-SlimAIR-500-H-P HRU-SlimAIR-500-H-CF-P HRU-SlimAIR-500E-H-P HRU-SlimAIR-500E-H-CF-P HRU-SlimAIR-800-H-P HRU-SlimAIR-800-H-CF-P HRU-SlimAIR-800E-H-P HRU-SlimAIR-800E-H-CF-P HRU-SlimAIR-1000-P 1000 HRU-SlimAIR-1000-CF-P 1000 HRU-SlimAIR-1000E-P 1000 HRU-SlimAIR-1000E-CF-P 1000 ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 95: Declaration Of Conformity

    Deklaracja ta jest podstawą oznaczania wyrobu znakiem przeprowadzone testy i badania. Deklaracja ta jest podstawą oznaczania wyrobu znakiem Alnor Systemy Wentylacji Sp. z o.o. Alnor Systemy Wentylacji Sp. z o.o. POLSKA 05-552 Wola Mrokowska, Aleja Krakowska 10 POLSKA 05-552 Wola Mrokowska, Aleja Krakowska 10 Tel.: + 48 22 737 40 00...
  • Page 96: Warunki Gwarancji Rekuperatora

    Działania siły wyższej np. uderzenia pioruna, powodzi, wania poprawek jest nieważna. Gwarancja bez pieczęci przepięć sieci elektrycznej, ekstremalnych warunkach firmy instalującej urządzenie jest nieważna. atmomosferycznych, uszkodzeń wynikłych w wyniku ® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 97: Karta Gwarancyjna

    Dodatkowa regulacja Inne ..................................................Proszę zakreślić właściwą odpowiedź: Czyszczenie filtrów rekuperatora Czyszczenie kratki wyrzutni/czerpni Kontrola stanu przewodów miesiące Dodatkowa regulacja Inne ..................................................® ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
  • Page 98: Recuperator Warranty Conditions

    Damage resulting from inadequate protection of the installations while other construction work is being ® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.
  • Page 99: Warranty Certificate

    Please circle the correct answer Cleaning the recuperator filters Cleaning of ejector/exhaust grille After 24 Checking the condition of the hoses months Additional adjustment Other ..................................................® ALNOR ventilation systems is a legally protected trademark and technical patent. All rights reserved.