PowerSpin
HXV
Series Centrifuge
(Models## C8306, C8608 and C8312)
OPERATION MANUAL
Dayton, NJ 08810, USA
732-274-1155 * www.unicosci.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the PowerSpin HXV Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unico PowerSpin HXV Series

  • Page 1  PowerSpin Series Centrifuge (Models## C8306, C8608 and C8312) OPERATION MANUAL Dayton, NJ 08810, USA 732-274-1155 * www.unicosci.com...
  • Page 2 HXV series centrifuges are designed with features to meet the safety and ™ functionality needs in today’s medical and health care industries. Description/ Intended Use: The UNICO ® PowerSpin HXV series centrifuge features a 0-99-minute electronic timer, digital time ™...
  • Page 3 1. Remove the centrifuge from its packaging and place it on a sturdy flat, dry surface. Special packing cushion foam is packed inside the rotor chamber of the centrifuge to protect the rotor and shields during shipping. 2. Turn on the centrifuge and press OPEN to open the lid. Remove the foam securing the rotor. You may open the lid via the emergency lid-opening hole: Locate the small hole on the front center of the centrifuge.
  • Page 4 Stop/Open Button: Press STOP/OPEN button to stop the centrifuge at anytime. Press this button to open the lid when the rotor is not spinning. Emergency Lid-opening: The lid features an electronically controlled safety system to prevent it from being opened accidentally while the centrifuge is spinning.
  • Page 5: Warranty

    Simple problems may be resolved over the telephone. If the instrument needs to be returned to UNICO, an R.G.A. (return goods authorization) number will be issued. Please reference the R.G.A. number on the paperwork packed with the instrument and on the outside of the carton.
  • Page 6 Note: This warranty will not extend to any repairs or modifications made to the instrument by some party other than the manufacturer or a party authorized by Unico. Also, this warranty shall be in effect only upon the notice of the defect to the manufacturer or it’s authorized distributor, or dealer, within five (5) days after the occurrence of said defect.
  • Page 7 PowerSpin™ HXV Centrifuge Parts and Nomenclature Model C8312 shown Rotor Spindle Emergency Rotor Lid opening Manual lock override Power indicator light Display Start, Stop& Open keys Timer and Speed Setting...