14. Using a pair of fine Needle Nose Pliers, carefully grab the Pin Terminal
(Note - Tweeter Magnet will attract the
Terminal
to break the adhesive bond.
15. Carefully pry upward to disengage and remove the Pin Terminal from its
mating Connector.
16. Take care not to grab the black plastic Insulator with the Pliers.
17. Figure 11 shows the High Frequency Voice Coil Assembly's broken Pin
Terminal, after it has been removed from its mating Connector.
Figure 10
Pliers)
and gently
Figure 11