IR remote for easy access to all functions and display configuration. • Autonomous TCXO time base, with the possibility of synchronization using the following: DCF 77 radio signal, one-minute 24 V pulses, the MOBATIME serial code, MOBALine, RS-232, RS-485, IRIG-B or GPS. •...
Configure the Line type jumper according to used synchronization signal (applies only for DCF, MOBALine, Serial MOBATIME code, polarized impulse line or IRIG-B). Mount back the connector cover. Tilt the clock into vertical position and fix the position of the console.
Page 15
Configure the Line type jumper according to used synchronisation signal (applies only for DCF, MOBALine, Serial MOBATIME code, polarized impulse line or IRIG-B). Mount back the connector cover. Tilt the clock parts into vertical position and fix them by locking screws.
Function of the Plug Connectors ➀ LINES, DC/DCF OUT – JP1 Time signal inputs: The DCF/GPS receiver, polarized impulse line, MOBALine, MOBATIME serial code, IRIG-B Power supply output: DC OUT 12–40 VDC or passive DCF current loop output ➁ TEMP – JP2 Connection of the temperature sensor(s) ➂...
IN1–, IN2+, IN2–, IN3+, IN3–. • By standard, only sensors with the same output type can be connected to DT display, i.e. a sensor with electric current output in the range 0–20 mA or 4–20 mA (for AIC) or a sensor with voltage output in the range 0–10 V (for AIV).
Setting of Time Synchronization Type Configure the jumper JP11 according to table (chapter 3.6) if the source of synchronization is DCF signal, MOBATIME serial code, polarized impulse line, MOBALine or IRIG-B. Choose the item in main MENU (chapter 8) and set the type of synchronization.
When the normal operation of the line resumes, the slave clock adjusts itself to the time equal to the master clock. 4.5. Slave Clock Controlled by MOBATIME Serial Code, MOBALine, or IRIG-B • After the connection of the digital clock to the signal source, time and date are adjusted automatically, following the receipt of valid time information.
Selection of the time-zone server time zone. Display time and date according to chosen time-zone server time zone, incl. daylight saving time. This setting is suitable for NTP digital clocks controlled by MOBATIME NTP servers which support the time-zone server functionality. 5.4.
Pushing the OK button returns to the clock menu item P6. 7.6.1. DST Defined by Entering Fixed Date and Time is set in item dt:, by pushing SET enter the submenu for entering fixed date If the value and time. The item to be set is blinking.
The daylight saving time has been set to start on April 28th at 2 o’clock and end on October 10th at 3 o’clock in the above described example By pushing OK save the setting and return to item dt:, Another push of the OK button returns to the clock menu item P6.
The daylight saving time has been set to start on last Sunday in March at 2 o’clock and end on last Sunday in October at 3 o’clock in the above described example. By pushing OK save the setting and return to item dt:. Another push of the OK button returns to the clock menu item P6.
Page 47
NTP unicast Internal GPS receiver Time zone for MOBALine 1–20, (off) – for MOBALine or time-zone server 1–15, (off) – for NTP MOBATIME Time zone of displayed time 0–64, (automatically), (user-defined) and date 1|–2 Time format display Time with leading zero Time without leading zero 1–2|...
9.1. Service Menu The service menu allows to invoke various special functions and some low-level settings can be made such as setting for the double-sided DT displays. The items in the service menu prefix, e.g. C0:00. are marked by Entering the service menu: MENU •...
45–60 VA 28 VA Power supply DC (on request) 30–36 VA 45–69 VA 60–92 VA 45–69 VA 60–92 VA – DT.100 20–30 VA 30–45 VA 45–60 VA 30–45 VA 45–60 VA 28 VA Powe consumption DT.180 30–36 VA 45–69 VA 60–92 VA...
Parameter DT.100 13.5 13.5 Weight (approx.) [kg] DT.180 – DT.100 Dimensions (approx.) [mm] DT.180 1090 1090 – 13.2. Voltage Range and Electric Current Consumption of the Lines Type of Slave Line Voltage Range Electric Current Consumption MOBALine 5–30 VAC 6–34 μA MIN, CODE ±12–30 V...
• IR remote control unit 1 pc • Wood screws for fixing the suspension, including dowels 4 (6) pcs • User manual BE-800845.10-DT 100-DT 180 temperature display_241203 1 pc 14.2. Double-sided Display • IR remote control unit 1 pc •...