Mobatime DT User Manual

Mobatime DT User Manual

Time / temperature display
Table of Contents

Advertisement

Quick Links

User Manual
DT
Time / Temperature Display
©MOBATIME
BE-800845.10-DT 100-DT 180 temperature display_241203

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DT and is the answer not in the manual?

Questions and answers

Summary of Contents for Mobatime DT

  • Page 1 User Manual Time / Temperature Display ©MOBATIME BE-800845.10-DT 100-DT 180 temperature display_241203...
  • Page 3: Important Notes

    BÜRK MOBATIME GmbH, D-78026 VS-Schwenningen / GERMANY and MOSER-BAER AG – CH 3454 Sumiswald / SWITZERLAND. Copyright © 2024 BÜRK MOBATIME GmbH, D-78026 VS-Schwenningen / GERMANY and MOSER-BAER AG – CH 3454 Sumiswald / SWITZERLAND. All rights reserved..
  • Page 4: Table Of Contents

    Output (Only for AIC/AIV Option) ................... 21 Setting of Time Synchronization Type ..........22 4.1. Autonomous Clock Synchronized by DCF 77 Receiver ............. 22 4.2. Autonomous Clock Synchronized by GNSS 4500 Receiver ..........22 4.3. Autonomous Clock Synchronized by Internal GPS Receiver ..........23 ©MOBATIME BE-800845.10...
  • Page 5 4.4. Slave Clock Controlled by Synchronizing Impulses ............23 4.5. Slave Clock Controlled by MOBATIME Serial Code, MOBALine, or IRIG-B ..... 24 4.6. Cascaded Connection of the DCF/GPS Synchronised Clock ........... 24 4.7. Synchronization by NTP Protocol ..................24 4.7.1.
  • Page 6 Table of the Addresses for the TP RS485 ........... 59 Technical Parameters ..............60 13.1. Basic Data ..........................60 13.2. Voltage Range and Electric Current Consumption of the Lines ........61 Accessories .................. 62 14.1. Single-sided Display ......................... 62 ©MOBATIME BE-800845.10...
  • Page 7 14.2. Double-sided Display ........................ 62 14.3. Optional Accessories ....................... 62 Warranty ..................63 ©MOBATIME BE-800845.10...
  • Page 8: Safety

    Connect device to earth ground. More information included in the manual. Disconnect mains power before doing anything. An example or a hint. Attention of electrical shocks. Surface may be hot. Item is flammable. A warning, be cautious. ©MOBATIME 8 / 64 BE-800845.10...
  • Page 9: General

    • The product was stored under adverse conditions. • Tough conditions during transport. Improper handling of this product operated on the mains voltage can cause mortal danger from electric shock! ©MOBATIME 9 / 64 BE-800845.10...
  • Page 10: Installation

    Use the product in the specified environment. Use outside of the specifications can damage the product and/or stop any operation. The product may not be exposed to extreme temperatures, direct sunlight or strong vibrations. Protect the product from moisture, dust and dirt. ©MOBATIME 10 / 64 BE-800845.10...
  • Page 11: Maintenance And Cleaning

    Unusable batteries can be returned free of charge at appropriate collection points of your waste disposal company or at shops that sell batteries. By doing so, you fulfil your legal responsibilities and help protect the environment. ©MOBATIME 11 / 64 BE-800845.10...
  • Page 12 This product was packed and stuffed with proper materials to protect it during transportation. Packaging materials can be recycled and should be disposed environmentally friendly. ©MOBATIME 12 / 64 BE-800845.10...
  • Page 13: Description

    IR remote for easy access to all functions and display configuration. • Autonomous TCXO time base, with the possibility of synchronization using the following: DCF 77 radio signal, one-minute 24 V pulses, the MOBATIME serial code, MOBALine, RS-232, RS-485, IRIG-B or GPS. •...
  • Page 14: Installation

    Configure the Line type jumper according to used synchronization signal (applies only for DCF, MOBALine, Serial MOBATIME code, polarized impulse line or IRIG-B). Mount back the connector cover. Tilt the clock into vertical position and fix the position of the console.
  • Page 15 Configure the Line type jumper according to used synchronisation signal (applies only for DCF, MOBALine, Serial MOBATIME code, polarized impulse line or IRIG-B). Mount back the connector cover. Tilt the clock parts into vertical position and fix them by locking screws.
  • Page 16: Mechanical Drawings

    3.3. Mechanical Drawings DT.100/57.1C.2T Luft T° Wasser T° ©MOBATIME 16 / 64 BE-800845.10...
  • Page 17: Connectors And Control Elements

    LAN – JP7 (NTP variant) LED indication of DCF signal ➇ ➑ PROG – JP8 state LED ➈ ➒ RELAY – JP27 (optionally) LED indication of power ➓ connector DC Out / DCF Out – JP17 ©MOBATIME 17 / 64 BE-800845.10...
  • Page 18: Function Of The Plug Connectors

    Function of the Plug Connectors ➀ LINES, DC/DCF OUT – JP1 Time signal inputs: The DCF/GPS receiver, polarized impulse line, MOBALine, MOBATIME serial code, IRIG-B Power supply output: DC OUT 12–40 VDC or passive DCF current loop output ➁ TEMP – JP2 Connection of the temperature sensor(s) ➂...
  • Page 19: Tp 3M / Tp 30M Temperature Sensors Connection

    Both temperature sensor types are connected to the JP2 connector terminals using three wires (see the illustration). • It is possible to connect up to two temperature sensors to single display device, other displays can’t be connected to the sensor(s). ©MOBATIME 19 / 64 BE-800845.10...
  • Page 20: Tp Rs485 Temperature Sensors Connection

    Moreover more display units can communicate to single temperature sensor, single display can communicate to up to three sensors. • The connection is done using standard UTP or STP cable and network infrastructure • The sensor is powered from small AC/DC wall adapter. ©MOBATIME 20 / 64 BE-800845.10...
  • Page 21: Connection Of Temperature Sensors With Electric Current Output Or Voltage Output (Only For Aic/Aiv Option)

    IN1–, IN2+, IN2–, IN3+, IN3–. • By standard, only sensors with the same output type can be connected to DT display, i.e. a sensor with electric current output in the range 0–20 mA or 4–20 mA (for AIC) or a sensor with voltage output in the range 0–10 V (for AIV).
  • Page 22: Setting Of Time Synchronization Type

    Setting of Time Synchronization Type Configure the jumper JP11 according to table (chapter 3.6) if the source of synchronization is DCF signal, MOBATIME serial code, polarized impulse line, MOBALine or IRIG-B. Choose the item in main MENU (chapter 8) and set the type of synchronization.
  • Page 23: Autonomous Clock Synchronized By Internal Gps Receiver

    After receiving each impulse is displayed time increased by one minute (or by 30 seconds or 1 second respectively). • After the expiration of run-out time the slave clocks are synchronized by the time information generated by the master clock, the colon flashes constantly. ©MOBATIME 23 / 64 BE-800845.10...
  • Page 24: Slave Clock Controlled By Mobatime Serial Code, Mobaline, Or Irig-B

    When the normal operation of the line resumes, the slave clock adjusts itself to the time equal to the master clock. 4.5. Slave Clock Controlled by MOBATIME Serial Code, MOBALine, or IRIG-B • After the connection of the digital clock to the signal source, time and date are adjusted automatically, following the receipt of valid time information.
  • Page 25: Synchronization By Ntp Unicast

    10. • Set item • According to chapter 7.5 set IP address of NTP server and polling interval. For correct displaying time and date choose desired time zone in item P6. • ©MOBATIME 25 / 64 BE-800845.10...
  • Page 26: Setting The Way Of Displayed Time And Date Calculation

    This setting is suitable for digital clocks controlled by a master clock as a MOBALine slave clock in a time distribution system with possibility to display different MOBALine time zones. ©MOBATIME 26 / 64 BE-800845.10...
  • Page 27: Calculation Using Time-Zone Server Mobatime

    Selection of the time-zone server time zone. Display time and date according to chosen time-zone server time zone, incl. daylight saving time. This setting is suitable for NTP digital clocks controlled by MOBATIME NTP servers which support the time-zone server functionality. 5.4.
  • Page 28: Setting The Network Parameters For Ntp Versions

    Inserted commands can be send-off using Enter key, the Backspace key serves for correction of the typing errors. help • Command displays help with command’s list. reset • Command makes clock reset (setting modifications are written to data flash). ©MOBATIME 28 / 64 BE-800845.10...
  • Page 29: Setting Of The Network Parameters By Dhcp

    IP addresses up to four NTP servers can be set using the DHCP option. Following options are supported: • Option code 42 – NTP servers. For NTP address assignation, NTP unicast synchronization must be selected. ©MOBATIME 29 / 64 BE-800845.10...
  • Page 30: Control Of The Display Using Ir Remote Control

    Decrease of the value adjusted, in steps of 1 Holding the + Continuous increase of the value set up push-button Holding the – Continuous decrease of the value set up push-button Return into normal display mode, without storage of the data ©MOBATIME 30 / 64 BE-800845.10...
  • Page 31: Setting Of Time And Date

    Submenu for User-specific Setting of Time Constants for Data Switchover (time constants for automatic switching over of values), set the value U, then In menu item enter the submenu by pushing SET button on the IR remote controller. ©MOBATIME 31 / 64 BE-800845.10...
  • Page 32: Setting Of Ntp Multicast Synchronization

    (in seconds): By pushing OK are the entered values stored and the display returns to the menu item P4. By pushing ESC return to item without storing. ©MOBATIME 32 / 64 BE-800845.10...
  • Page 33: Submenu For Setting Of The User-Specific Time Zone

    Pushing the OK button returns to the clock menu item P6. 7.6.1. DST Defined by Entering Fixed Date and Time is set in item dt:, by pushing SET enter the submenu for entering fixed date If the value and time. The item to be set is blinking.
  • Page 34: Dst Defined By Entering Calculated Date

    The daylight saving time has been set to start on April 28th at 2 o’clock and end on October 10th at 3 o’clock in the above described example By pushing OK save the setting and return to item dt:, Another push of the OK button returns to the clock menu item P6.
  • Page 35: Setting Of The Predefined Temperature Value

    The daylight saving time has been set to start on last Sunday in March at 2 o’clock and end on last Sunday in October at 3 o’clock in the above described example. By pushing OK save the setting and return to item dt:. Another push of the OK button returns to the clock menu item P6.
  • Page 36: Settings For The Tp 3M / Tp 30M Temperature Sensors

    On the single RS485 bus just one display device must be master and the others must be listeners. By pushing OK, the entered values are stored and the display returns to the menu item (or P14, respectively). By pushing ESC return without storing. ©MOBATIME 36 / 64 BE-800845.10...
  • Page 37: Settings For The Tp Lan Temperature Sensors

    Enter the address of the AD converter, by standard, the address equals 1. The table in chap. 12 shows numeric demonstration of individual addresses. By pressing the >> button switch to the setting of the regime of communication with the AD converter. The display shows ©MOBATIME 37 / 64 BE-800845.10...
  • Page 38 By pressing the >> button switch to the setting of the temperature value corresponding to the maximal value of the output electric current or the output voltage. The display shows rxxx. Enter the temperature value in °C, the range is from -99 to 999 °C. ©MOBATIME 38 / 64 BE-800845.10...
  • Page 39: Setting Parameters For The Tphp Rs485 Temperature Sensors

    At set value the measured humidity is displayed permanently, i.e. switching between measured values is forbidden. Press >> button to switch to humidity correction setting. Display shows ©MOBATIME 39 / 64 BE-800845.10...
  • Page 40: Setting Parameters For The Tphp Lan Temperature Sensors

    Enter the temperature correction value in format, the range is from -9.9 to +9.9 °C. Press the >> button to switch to the setting of the measured humidity time constant for display switching. The display shows ©MOBATIME 40 / 64 BE-800845.10...
  • Page 41: Setting Parameters For The Tphb Rs485 Temperature Sensors

    Pressing the >> button switches to the time constant of the measured temperature for display switching. The display shows Enter a time constant value between 1 and 60 seconds. The value determines the display time of the measured temperature during the display switching process between the measured ©MOBATIME 41 / 64 BE-800845.10...
  • Page 42 It is compulsory to keep the time constant settings for display switching the rule is that the value of should be set to only one measured maximum the value and the value must not be set for all measured variables. ©MOBATIME 42 / 64 BE-800845.10...
  • Page 43: Settings For The Tp Lan Poe Temperature Sensors

    If set to n, the temperature display is disabled. At set to the measured temperature is displayed permanently, i.e. switching between measured values is forbidden. Press the >> button to switch to the temperature correction setting. ©MOBATIME 43 / 64 BE-800845.10...
  • Page 44: Manual Setting Of The Ip Address Of The Clock

    By pushing ESC the clock returns to without storing. 7.18. Manual Setting of the Subnet Mask Choose the item in the main menu and push the SET button to enter the submenu for setting the subnet mask. ©MOBATIME 44 / 64 BE-800845.10...
  • Page 45: Manual Setting Of Default Gateway Ip Address

    << and >> buttons. Octets are marked by letters A, b, and d. By pushing OK, the entered values are stored and the clock returns to the menu item P20. By pushing ESC the clock returns to without storing. ©MOBATIME 45 / 64 BE-800845.10...
  • Page 46: Menu Table

    Time zone of 0–64, (automatically) synchronization source 1–10, (automatically) Auto detection, applicable for: DCF, the MOBATIME serial code, MOBALine, IRIG-B or GPS Autonomous operation without Synchronization source synchronization Synchronization by DCF signal The MOBATIME serial code MOBALine ©MOBATIME 46 / 64 BE-800845.10...
  • Page 47 NTP unicast Internal GPS receiver Time zone for MOBALine 1–20, (off) – for MOBALine or time-zone server 1–15, (off) – for NTP MOBATIME Time zone of displayed time 0–64, (automatically), (user-defined) and date 1|–2 Time format display Time with leading zero Time without leading zero 1–2|...
  • Page 48 Temperature format display With decimal Without decimal 0–10 Use preset value TP3 / TP30 TP RS485 TP LAN Temperature sensor with analogue Temperature 1 function output TPHP RS485 TPHP LAN TPHB RS485 TPHB LAN TP LAN PoE ©MOBATIME 48 / 64 BE-800845.10...
  • Page 49 Temperature sensor with analogue output Temperature 2 function TPHP RS485 TPHP LAN TPHB RS485 TPHB LAN TP LAN PoE TPH 1m 0–10 Use preset value Temperature 3 function TP3 / TP30 TP RS485 TP LAN ©MOBATIME 49 / 64 BE-800845.10...
  • Page 50 TP LAN PoE TPH 1m 0–10 Use preset value TP3 / TP30 TP RS485 TP LAN Temperature sensor with analogue Temperature 4 function output TPHP RS485 TPHP LAN TPHB RS485 TPHB LAN TP LAN PoE ©MOBATIME 50 / 64 BE-800845.10...
  • Page 51 Firmware version e.g.: 1) Only for special option AIC/AIV. 2) Only for special design. Values marked by are default values. In values marked with the submenu is accessible by pushing the SET button. ©MOBATIME 51 / 64 BE-800845.10...
  • Page 52: Service Menu, Testing Mode, Parameter Reset, Double-Sided Clock

    9.1. Service Menu The service menu allows to invoke various special functions and some low-level settings can be made such as setting for the double-sided DT displays. The items in the service menu prefix, e.g. C0:00. are marked by Entering the service menu: MENU •...
  • Page 53: Setting For Double-Sided Clock

    In SLAVE mode the display shows the same data as the MASTER part except the MENU mode is entered. • If the connection with the MASTER part doesn’t work for more than three minutes, the all eights (88:88) display is shown on SLAVE part. ©MOBATIME 53 / 64 BE-800845.10...
  • Page 54: Firmware Update

    After entering the password, check if the firmware version is correct, if it isn’t, it is necessary to repeat the whole procedure. Close the telnet window and end the program tftpd32 with the command exit. • ©MOBATIME 54 / 64 BE-800845.10...
  • Page 55: Time-Zone Table

    UTC (GMT) Istanbul, Kuwait, Minsk, Moscow, Saint Petersburg, Volgograd Praia, Cape Verde UTC (GMT) Abu Dhabi, Muscat, Tbilisi, Samara Kabul +4.5 Adamstown (Pitcairn Islands) Tashkent, Islamabad, Kathmandu, Yekaterinburg Mumbai, Kolkata, Chennai, +5.5 New Delhi, Colombo ©MOBATIME 55 / 64 BE-800845.10...
  • Page 56 Third Sunday in February Brasília (00:00) (00:00) Buenos Aires Second Sunday in March First Sunday in Newfoundland -3.5 (02:00) November (02:00) Second Sunday in March First Sunday in Atlantic Time (Canada) (02:00) November (02:00) La Paz ©MOBATIME 56 / 64 BE-800845.10...
  • Page 57 Last Sunday in March Last Sunday in October Ittoqqortoormiit, Greenland (00:00) (01:00) Last Saturday in March Last Saturday in October Nuuk, Qaanaaq, Greenland (22:00) (23:00) Myanmar +6.5 Western Australia: Perth Caracas -4.5 Central European Time (CET) ©MOBATIME 57 / 64 BE-800845.10...
  • Page 58 Time change from Standard time (Winter time) to Summer time ☀ → ❄: Time change from Summer time to Standard time (Winter time) The penultimate Sunday in March (02:00): Switch over on the penultimate Sunday in March at 02:00 hours local time ©MOBATIME 58 / 64 BE-800845.10...
  • Page 59: Table Of The Addresses For The Tp Rs485

    12. Table of the Addresses for the TP RS485 Addr. Addr. Addr. Addr. Sensor address M: Number 48. ©MOBATIME 59 / 64 BE-800845.10...
  • Page 60: Technical Parameters

    45–60 VA 28 VA Power supply DC (on request) 30–36 VA 45–69 VA 60–92 VA 45–69 VA 60–92 VA – DT.100 20–30 VA 30–45 VA 45–60 VA 30–45 VA 45–60 VA 28 VA Powe consumption DT.180 30–36 VA 45–69 VA 60–92 VA...
  • Page 61: Voltage Range And Electric Current Consumption Of The Lines

    Parameter DT.100 13.5 13.5 Weight (approx.) [kg] DT.180 – DT.100 Dimensions (approx.) [mm] DT.180 1090 1090 – 13.2. Voltage Range and Electric Current Consumption of the Lines Type of Slave Line Voltage Range Electric Current Consumption MOBALine 5–30 VAC 6–34 μA MIN, CODE ±12–30 V...
  • Page 62: Accessories

    • IR remote control unit 1 pc • Wood screws for fixing the suspension, including dowels 4 (6) pcs • User manual BE-800845.10-DT 100-DT 180 temperature display_241203 1 pc 14.2. Double-sided Display • IR remote control unit 1 pc •...
  • Page 63: Warranty

    The following circumstances are excluded from the guarantee: • Inappropriate handling or interventions. • Chemical influences. • Mechanical defects. • External environmental influences (natural catastrophes). Repairs during and after the guarantee period are assured by the manufacturer. ©MOBATIME 63 / 64 BE-800845.10...
  • Page 64 ©MOBATIME BE-800845.10...