Download Print this page
Daikin CTXF35F5V1B Operation Manual

Daikin CTXF35F5V1B Operation Manual

R32 split series
Hide thumbs Also See for CTXF35F5V1B:

Advertisement

Quick Links

Operation manual
R32 split series
CTXF20F5V1B
Operation manual
CTXF25F5V1B
English
R32 split series
CTXF35F5V1B

Advertisement

loading
Need help?

Need help?

Do you have a question about the CTXF35F5V1B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin CTXF35F5V1B

  • Page 1: Table Of Contents

    Operation manual R32 split series CTXF20F5V1B Operation manual CTXF25F5V1B English R32 split series CTXF35F5V1B...
  • Page 2: Table Of Contents

    ▪ Detailed step-by-step instructions and background information 5.3.3 Airflow direction............for basic and advanced usage 5.3.4 Comfort airflow operation..........▪ Format: Digital files on https://www.daikin.eu. Use the search 5.3.5 Powerful operation ............function to find your model. 5.3.6 Econo operation............
  • Page 3: Instructions For Safe Operation

    2 User safety instructions concerning use of the appliance in a Instructions for safe operation safe way and understand the hazards WARNING: MILDLY FLAMMABLE involved. MATERIAL Children SHALL NOT play with the The refrigerant inside this unit is appliance. mildly flammable. Cleaning and user maintenance CAUTION SHALL NOT be made by children...
  • Page 4: About The System

    3 About the system WARNING heater). The room size shall be as specified in the General safety Do NOT place a flammable spray precaution. bottle near the air conditioner and do NOT use sprays near the unit. Doing DANGER: RISK OF so may result in a fire.
  • Page 5: Indoor Unit

    3 About the system NOTICE About the user interface Do NOT use the system for other purposes. In order to Wireless remote control avoid any quality deterioration, do NOT use the unit for cooling precision instruments, food, plants, animals, or INFORMATION works of art.
  • Page 6: Status: Wireless Remote Control Lcd

    4 Before operation 3.2.2 Status: Wireless remote control LCD Sound Description Beep-beep Operation starts. Beep Setting changes. Long beep Operation stops. 3.2.4 To adjust the louvers (vertical blades) 1 Hold 1 or both knobs and move the louvers. Icon Description Operation mode = Automatic Operation mode = Drying Operation mode = Heating...
  • Page 7: Operation

    5 Operation Result: The flap of the indoor unit will open and close to set the Operation mode and temperature reference position. setpoint When. Adjust the system operation mode and set the temperature Operation when you want to: ▪ Heat up or cool down a room Operation range ▪...
  • Page 8: Airflow Rate

    5 Operation To adjust the airflow direction Cooling Heating Automatic Drying or fan operation operation operation only operation 1 To use auto swing, press 18~32°C 10~30°C 18~30°C — Result: will appear on the LCD. 3 Press to stop operation. Result: The flap (horizontal blade) will begin to swing. Result: The operation lamp goes off.
  • Page 9: Econo Operation

    5 Operation To start/stop OFF timer operation Result: disappears from the LCD. Note: Powerful operation can be set only when the unit is running. If INFORMATION you press or if you change operation mode, operation will be When you set the ON/OFF timer, the time setting is stored cancelled;...
  • Page 10: Precautions When Using The Wireless Lan

    5 Operation ▪ Wireless LAN access point 2 Press to confirm the selection. ▪ Installed free ONECTA application Result: is blinking. 3 Check the operation and timer LEDs on the indoor unit display. 5.4.1 Precautions when using the wireless LAN Do NOT use near: ▪...
  • Page 11: Energy Saving And Optimum Operation

    6 Energy saving and optimum operation Result: is blinking. The operation and timer LEDs are blinking Maintenance and service at the same time in 1  s interval. The setting is reset to the factory default. Overview: Maintenance and 4 Press to exit the menu.
  • Page 12: To Clean The Indoor Unit And Wireless Remote Control

    7 Maintenance and service 2 Pull out the air filters. WARNING To prevent electrical shocks or fire: ▪ Do NOT rinse the unit. ▪ Do NOT operate the unit with wet hands. ▪ Do NOT place any objects containing water on the unit. CAUTION After a long use, check the unit stand and fitting for damage.
  • Page 13: To Take Following Items Into Account Before A Long Idle Period

    Refer reference guide located https:// www.daikin.eu for more troubleshooting tips. Use the ▪ While the air conditioner is not in operation. When the outdoor search function to find your model. temperature is very high, the outdoor fan starts to rotate for system protection.
  • Page 14: Solving Problems Based On Error Codes

    9 Disposal Solving problems based on error Error code Description DC voltage / current sensor abnormality codes Outdoor temperature thermistor abnormality Fault diagnosis by the wireless remote control Discharge pipe thermistor abnormality If the unit runs into a problem, you can identify the fault by checking Outdoor heat exchanger thermistor abnormality the error code by the wireless remote control.
  • Page 16 DAIKIN ISITMA VE SOĞUTMA SİSTEMLERİ SAN.TİC. A.Ş. Gülsuyu Mahallesi, Fevzi Çakmak Caddesi, Burçak Sokak, No:20, 34848 Maltepe İSTANBUL / TÜRKİYE Tel: 0216 453 27 00 Faks: 0216 671 06 00 Çağrı Merkezi: 444 999 0 Web: www.daikin.com.tr 3P717028-9J 2024.07...

This manual is also suitable for:

Ctxf25f5v1bCtxf20f5v1b