Troubleshooting - SATA filter 200 Operating Instructions Manual

Hide thumbs Also See for filter 200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 23
Operating instructions SATA filter 200
replace if necessary
• Unscrew intermediate adapter [4-5] at filter stage [B] and [C], then
remove [4-3] and replace fine or activated charcoal cartridge, resp.
• Installation has to be carried out in reverse order. Please make sure
that the filter cartridges are installed in the correct order. Coloured
markers (yellow = sintered filter [A], blue = fine filter [B], black = acti-
vated charcoal filter [C] allow clear identification [4-4]. Marking rings
are located on the threaded rods of the filter stages [B] and [C].
• During installation, please ensure proper seat and undamaged O-rings!
Notice!
Please observe local regulations for the disposal of filter cartridges!

11. Troubleshooting

Malfunction
Pressure cannot be
properly adjusted
Traces of compressor
oil in the compressed
air
No or insufficient con-
densate drainage (a
minimum condensate
level is required as it
serves to lift the floater
and, thus, to open the
drain valve)
Cause
Insufficient inlet pres-
sure
Pressure regulation
valve at air outlet mod-
ule is defective
Too much oil in the
compressed air
Saturated filter
Floater stuck on the
drain valve
Damaged drain valve
Corrective action
Increase inlet pressure
Exchange pressure
regulation valve [D],
Art. No. 171496
Control compressor,
refrigerated dryer
Drain condensate
(open manually)
Filter maintenance
required, chapter 10
Disassemble drain
valve by removing the
safety disc, then clean
or exchange drain
valve
Exchange drain valve
Art. No. 15511
EN
29

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the filter 200 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Filter 244Filter 284Filter 264

Table of Contents