INTRODUCTION 1.1 Introduction This user manual describes the Grip S1000 from Grip Lifting Equipment, based in Bergambacht in the Netherlands. The information in this manual plays an important role in ensuring the safe and proper operation of the machine. It concerns the original user manual which was created in the Dutch language by Grip Lifting Equipment (subsequently referred to as the manufacturer).
A number of pictograms are attached to the machine. Their aim is to warn the user of residual risks which could be present in spite of the safety measures taken. The table below provides an overview of the symbols used. User manual Glass suction lifter S1000...
The CE marking is attached to the type plate on the basis of this information (see figure 1). The directives and standards are stated on the Declaration of Conformity (see Annex 1). U.S1000.01.00.EN 1.0...
1.7 Type marking The machine is provided with the type plate shown below (see figure 1). Figure 1: Type plate User manual Glass suction lifter S1000...
▪ Follow the local work instructions and safety regulations. ▪ The user / owner of the machine is responsible for adherence to the instructions stated in this manual. ▪ The machine must not be used in an environment which is dusty or is exposed to gas. U.S1000.01.00.EN 1.0...
The Grip S1000 is a vacuum lifter for placement and movement of flat and non-porous glass panels which are of a medium to large size. The load must be sufficiently stiff to avoid excess bending or warping.
1 metre from the machine at a height of 1.60 metres above the shop floor. The level of the A-weighted equivalent continuous sound level (L ) is < 65 dB(A) in an operational state. U.S1000.01.00.EN 1.0...
▪ Do not keep the machine exposed to rain or direct sunlight for long periods. ▪ Charge the battery up following each use or on a monthly basis if the machine is not used for a long period. User manual Glass suction lifter S1000...
The power supply can be switched off via the On / Off switch on the machine. Once the machine has been switched off, the battery must also be disconnected before any maintenance work can be carried out. Figure 2 - On / Off switch U.S1000.01.00.EN 1.0...
There was a strong focus on ergonomic aspects during the design phase. The machine is designed and built in such a way that human ergonomic aspects are taken into account as much as possible. User manual Glass suction lifter S1000...
WARNING OF DANGER: Never lift a load up above yourself or any other people. This is strictly prohibited! CAUTION: Operators must be above the age of 18 and they must not be under the influence of alcohol, narcotics or medication. U.S1000.01.00.EN 1.0...
Page 16
ATTENTION: The operator is only allowed to carry out tasks for which training has been received. This applies for maintenance and operational tasks. User manual Glass suction lifter S1000...
Operation 6.2 Configurations Machine weight 85 kg Lifting capacity 600 kg Dimensions 1500 x 1150 mm Machine weight 90 kg Lifting capacity 600 kg Dimensions 2500 x 900 mm U.S1000.01.00.EN 1.0...
Page 18
Machine weight 110 kg Lifting capacity 1000 kg Dimensions 2500 x 1150 mm Machine weight 110 kg Lifting capacity 1000 kg Dimensions of short lifting arm 2500 x 1550 User manual Glass suction lifter S1000...
The safety devices and alarms will not work when the machine is connected to the load while switched off. Check the position of the machine on the load. ▪ See § 6.4 Operating instructions for this. Check whether all locking pins are present and correctly locked in place. U.S1000.01.00.EN 1.0...
• K: Control lever for rotation mechanism • L: On/Off switch • M: Charging port • N: Locking pin for extension tube • O: Locking pin for suction cup • P: Vacuum quick coupling User manual Glass suction lifter S1000...
▪ Pull the control lever towards you. ▪ Rotate the pane of glass to the desired position. ▪ Push the control lever to the start position > Check whether the lever is pushed right back. U.S1000.01.00.EN 1.0...
Always communicate with the persons present prior to moving the load or releasing the machine from the load ▪ This is particularly important if the machine is being operated with the remote control. • User manual Glass suction lifter S1000...
6.7 Conditions after use Put the machine back on the transport dolly or support after use. Make sure that the machine is not resting on the sealing edge of the suction cups. This can cause permanent distortion of the sealing edge U.S1000.01.00.EN 1.0...
The table below provides an overview of the necessary maintenance and inspection tasks. Table 3: Maintenance & inspection schedule Frequency Action Daily Monthly Annually Every three years Suction cup ⚫ Visual check ⚫ Clean ⚫ Full inspection Signalling & indicators User manual Glass suction lifter S1000...
Page 25
Check the machine as a whole for damage or distorted parts. Specifically check the holes of the connecting pins and the connecting pins themselves. If one of the parts is damaged in some way, it must be replaced before work with the machine can continue. U.S1000.01.00.EN 1.0...
Do not continue to work with the machine until the malfunction has been rectified. Malfunction Possible cause Solution - Battery is discharged or defective - Charge or replace battery Machine does not switch on - Fuse is blown - Replace fuse User manual Glass suction lifter S1000...
Only generally known materials are processed in the machine. There were accepted possibilities for waste processing for these materials during production and no specific risks were known of in relation to the disassembly and the removal of these materials. Most parts of the machine can be recycled. U.S1000.01.00.EN 1.0...