Download Print this page

Prysmian CIG0148 Instruction Manual

Aerial cable cbt system

Advertisement

Quick Links

Cable Instruction Guide
Installation Procedure For Aerial Cable CBT System
CIG0148
Product application
This instruction details the installation procedure for the Aerial Cable CBT System.
Port Number
1
2
3
4
5
6
Precautions and Warnings
!
This guide is only valid for products purchased from or approved by Prysmian Group.
!
During this procedure all local Health & Safety statutory regulations must be adhered to.
!
This installation should only be carried out by suitably trained competent persons.
!
6.0mm Cable Parameters
Minimum Bend Diameter (Static) – 120mm
Maximum Working Tension
Typical Installation Tension
Feeder Cable Fibre Colour
Blue
Orange
Green
Red
Grey
Yellow
– 1000N
– 150N
www.prysmiangroup.com
Port Number
Feeder Cable Fibre Colour
7
8
9
10
11
12
Issued 2024-11-13 RSu/ Page 1 of 18
Brown
Violet
Black
White
Pink
Turquoise
CIG0148-WW-en-v4

Advertisement

loading
Need help?

Need help?

Do you have a question about the CIG0148 and is the answer not in the manual?

Questions and answers

Summary of Contents for Prysmian CIG0148

  • Page 1 Turquoise Precautions and Warnings This guide is only valid for products purchased from or approved by Prysmian Group. During this procedure all local Health & Safety statutory regulations must be adhered to. This installation should only be carried out by suitably trained competent persons.
  • Page 2 PN: XTCSC00019 PN: XTCSC00021 PN: XTCSC00008 PN: XTCSC00025 11. 4/12f Drop Cable 12. Side Cutters 13. PVC Tape 14. CBT Connector Tool Sheath Stripper PN: XBFSC01760 PN: n/a PN: n/a PN: XKTSC01437 www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 2 of 18...
  • Page 3 Secure the feeder cable down the Install the cable through the Fit the capping adaptor to the base pole using pole cleats. underground network to the joint of the pole. position. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 3 of 18...
  • Page 4 Underground Joint Chamber CBT Terminal Installation Step 11 No Picture The CBT can be installed within an underground chamber. It should be secured to either the chamber wall or onto a MOBRA. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 4 of 18...
  • Page 5 Care should be taken to ensure that the cable does not infringe the minimum ground clearance requirements under worst case conditions. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 5 of 18...
  • Page 6 This could be the CBT External Customer inside or outside the building. Termination Box. Mark the cable at this point and add an extra 3m. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 6 of 18...
  • Page 7 Separate the two halves of the Fibre Carefully cut the two halves of the Drop Cable sheath back to the mark cable sheath, non-mettalic yarns and made in step 25. the steel wire strength members. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 7 of 18...
  • Page 8 Mk 2 Step 34 Step 35 Slide the rubber boot away from the If the cable is installed within the assembly. clamp nut then this indicates a Mark 2 Pre-connectorised Assembly www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 8 of 18...
  • Page 9 The CBT Port Cap retaining straps and Alternatively, they can be screwed those on the Pulling Eye can be together and kept with the CBT. Note: The colour may differ. removed if required. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 9 of 18...
  • Page 10 Tighten the clamp nut ensuring the on the port and insert the shroud into the shroud nut fully. seal is in the end of the shroud. the port. Step 51 Re-fit the rubber boot. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 10 of 18...
  • Page 11 Pulling Eye can be Note: The colour may differ. port on the CBT. There is a number removed if required. by the port for identification. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 11 of 18...
  • Page 12 Step 67 Step 68 Tighten the clamp nut ensuring the Slide the rubber boot over the clamp seal is in the end of the shroud. nut. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 12 of 18...
  • Page 13 Attach the pulling bond to the tension Secure the end of the pulling bond the drop cable. clamp. with pvc tape Note the position of the clamp relative to the connector. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 13 of 18...
  • Page 14 Apply a circumferential cut to the and position approximately 65mm loose tube at the cable butt loose tube at 1m from the end of the from the lowest face of the box. tube. www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 14 of 18...
  • Page 15 Fit the tube to the reducing Locate the completed tube assembly locking tube. connector. into position and clip the connector Please Note: The locking tube is pre-cut into place. to the correct length www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 15 of 18...
  • Page 16 Step 103 Wrap the locking tube around the If the wrapping is done correctly there Trim the output gland to the size for mandrels. will be no excess tube. the outlet cable www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 16 of 18...
  • Page 17 Copyright Prysmian Group - 2024 You may not copy, reprint, or reproduce in any form the content, either wholly or in part, of this Installation Guide, without the written permission of the copyright owner. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result.
  • Page 18 T: +7 495 777 80 86 info.ru@prysmiangroup.com F: +7 495 777 80 89 SPAIN & AFRICA Maliaño T: +34 942247118 santander.bo@prysmiangroup.com F: +34 942247114 TURKEY Istanbul tpks@prysmiangroup.com Eastleigh T: +44 2380 295 000 sales.telecom.uk@prysmiangroup.com www.prysmiangroup.com CIG0148-WW-en-v4 Issued 2024-11-13 RSu/ Page 18 of 18...