  • Page 1 QUICK START GUIDE SST4 Pump QSG-SST4 Pump-Rev 1.2 19.06.2024...
  • Page 2 • This detector is a personal safety device. It is your • Only use WatchGas chargers. Using other Non- responsibility to respond properly to any alarm Approved chargers can lead to fire and/or explosion.
  • Page 3 • Before using the detector, refer to Sensor Poisons et annulera la garantie du produit. (Sauf remplacement and Contaminants (see SAFETY INFORMATION - par un technicien de service agréé WatchGas utilisant READ BEFORE USE chapter). des pièces WatchGas d’origine.) • La désactivation du détecteur en retirant la batterie peut entraîner un mauvais fonctionnement et...
  • Page 4 WatchGas agréé. substituído por um técnico de serviço aprovado pela • Avant d’utiliser le détecteur, reportez-vous à la WatchGas usando peças originais da WatchGas.) section Poisons et contaminants du capteur (voir le • Desativar o detector removendo a bateria pode...
  • Page 5 21,0% v/v. Use apenas carregadores WatchGas. O uso de outros Se o filme antiestático do display LCD estiver carregadores não aprovados pode causar incêndio e/ danificado, não use e entre em contato com seu...
  • Page 6 If an alarm occurs due to high Sensor contaminate concentration of combustible gases, calibrate the WatchGas recommends the catalytic combustible detector. If necessary, replace the sensor. sensor be checked with a known concentration of Do not expose the detector to electrical shock and/or calibration gas after any known exposure to catalyst severe continuous mechanical shock.
  • Page 7 Charge only in a safe area that is free of hazardous gas IEC 60079-0:2017 and within temperatures of 32°F to 113°F (0°C to 45°C) IEC 60079-11:2011 First-time charge: 3 hours. IEC 60079-28:2015 Normal charge: SST4 Pump: 4-6 hours. Indication Error LEL:± 5% FS...
  • Page 8 • Sensors: H2S, SO2, CO, O2, and combustible (LEL) (LPC, CAT or IR) as ordered 19.5% Vol 23.5% Vol N/A • Male Luer These set points can be changed using the WatchGas • Calibration Hose 30cm/1ft SST Application. • Printed Quick Start Guide •...
  • Page 9 WARNING: If the Pump Cover is NOT installed, the GETTING STARTED unit cannot be calibrated in order to ensure a full verification of the device. If the pump cover is mounted upon start up, the pump will automatically start when the detector is turned on. After the sensor warm up, the device will require the user to “BLOCK INLET”...
  • Page 10 DISPLAY will light up as above showing all segments allowing the user to fully verify the correct function. A self-test can be performed by holding the button for External filter 3 seconds, after the detector will alarm and light up the PN: SST-WTF-001 display.
  • Page 11 ALARM INFORMATION Product Compliant Alarm Notification Product Non-Compliant Low Alarm Calibration Required High Alarm Bump Required Short Term Exposure Alarm NFC in Communication Time Weighted Average Alarm Battery level Indicate LOW LOW or HIGH HIGH alarm. 3rd alarm level Mute SENSORS Pump ON Hydrogen sulfide sensor...
  • Page 12 13. Inert On (only if configured) the NFC Icon flashes. Screen shots are available in the full manual. Use the WatchGas SST Application or a SST Dock to configure the unit. Details are in the manual. The SST Range products are shipped with following...
  • Page 13 The SST Range products can only be calibrated with Detection range: the WatchGas SST Application or an SST Dock. H2S: 0 – 500 ppm (1 / 0.1 ppm increments) CO: 0 – 2000 ppm (1 ppm increments) CONNECT GAS O2: 0 –...
  • Page 14 5 seconds; also activates during Where a product within the warranty period has a an alarm condition defect or a quality issue, WatchGas provides the buyer with a repair or a replacement for free of charge direct CHARGING THE SST RANGE from WatchGas or through an authorized Partner / Service Center.